Improving How Older Adults at Risk for Cardiovascular Outcomes Are Selected for Care Coordination
NCT05820295
Arrhythmias, Cardiac, Atrial Fibrillation
New York, United States
View Trial DetailsNCT Number: NCT01930695
The study is designed to collect data of the performance and confirm the safety of the DX (Diagnostic eXtension) functionality in the Lumax 640/470 HF-T in patients with permanent atrial fibrillation and CRT-D indication according to current ESC guidelines. The DX functionality is a feature, which can be activated in the Lumax 640/740 HF-T when connected to the LinoxSMART S DX right ventricular lead. The combination of these devices enable atrial sensing via a sensing dipole in the ventricular lead and therefore reduces the number of implanted leads without sacrificing atrial information. Atrial pacing can not be provided but is not needed in patients with permanent atrial fibrillation.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Herz- und Gefäßzentrum Bad Bevensen, Bad Bevensen, Germany
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: 3 months
to assess if the IEGM Online recordings of the Lumax 640/740 HF-T with DX functionality provide adequate quality to classify the atrial rhythm
Time frame: 3 months
to assess the safety of the Lumax 640/740 HF-T by the analysis of Serious Adverse Device Effects which are related to the DX functionality
Time frame: 3 months
to assess the safety of the Lumax 640/740 HF-T with DX functionality by the analysis of all (serious and non-serious) Adverse Device Effects which are related to the DX functionality
Time frame: 3 months
to investigate whether the diagnosis of permanent AF at enrollment is maintained after device implantation
Biotronik SE & Co. KG
Industry
Acronym: Pre-CRAFT
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05820295
Arrhythmias, Cardiac, Atrial Fibrillation
New York, United States
View Trial DetailsNCT01420393
Arrhythmias, Cardiac, Atrial Fibrillation
Porto Alegre, Rio Grande do Sul, Brazil
View Trial DetailsNCT04461691
Arrhythmias, Cardiac, Atrial Fibrillation
Wiesbaden, Germany
View Trial DetailsNCT05118893
Arrhythmias, Cardiac, Atrial Fibrillation
Calgary, Alberta, Canada
View Trial Details