Completed

NCT Number: NCT01980901

Post-Approval Study of the Ovation™/Ovation Prime™ Abdominal Stent Graft System

The Post-Approval Study (PAS) will evaluate the "real world" data on the Ovation™/Ovation Prime™ Abdominal Stent Graft System along with the long-term data collected from the IDE cohort to monitor the long-term safety and effectiveness of the device.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Christie Clinical Vein and Vascular Center

Champaign, Illinois, 61820, United States

About this study

The purpose of the study is to demonstrate the long term safety and effectiveness of the Ovation™/Ovation Prime™ Abdominal Stent Graft System for the endovascular treatment of infrarenal abdominal aortic aneurysms in a post-approval environment.

The clinical objective of the study is to evaluate the long term safety and effectiveness of the Ovation™/Ovation Prime™ Abdominal Stent Graft System assessed at 5 years through freedom from Aneurysm-Related Mortality.

Additionally, this study will evaluate the physician training program for modifications based on IDE and post-approval experience.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patient is > 18 years of age.
  • Patients who are male or non-pregnant female (females of child bearing potential must have a negative pregnancy test prior to enrollment into the study).
  • Patient has signed an Institutional Review Board (IRB) approved Informed Consent Form.
  • Patient is considered by the treating physician to be a candidate for elective open surgical repair of the AAA (i.e., category I, II, or III per American Society of Anesthesiology (ASA) classification; refer to Appendix III: ASA Classification System). ASA category IV patients may be enrolled provided their life expectancy is greater than 1 year.
  • Patient has an infrarenal abdominal aortic aneurysm that meets at least one of the following:
  • Abdominal aortic aneurysm >5.0 cm in diameter
  • Aneurysm has increased in size by 0.5 cm in last 6 months.
  • Maximum diameter of aneurysm exceeds 1.5 times the transverse dimension of an adjacent non-aneurysmal aortic segment
  • Patient has patent iliac or femoral arteries that allow endovascular access with the TriVascular Ovation/Ovation Prime Abdominal Stent Graft System.
  • Patient has a suitable non-aneurysmal proximal aortic neck length of ≥ 7 mm inferior to the most distal renal artery ostium.
  • Patient has a suitable non-aneurysmal distal iliac artery length (seal zone) of ≥10 mm. The resultant repair should preserve patency in at least one hypogastric artery.
  • Patient has a suitable non-aneurysmal proximal aortic neck luminal diameter between 16 and 30 mm.
  • Patient has suitable non-aneurysmal distal iliac luminal diameters between 8 and 20 mm.
  • Patient meets the following anatomic criteria: the distance from the most distal renal artery to most superior internal iliac artery measurement is at least 13 cm.
  • Patient has juxtarenal aortic neck angulation ≤ 60º if proximal neck is ≥10 mm and ≤ 45º if proximal neck is <10 mm. Patient must be willing to comply with all required follow-up exams.
  • Patient must be willing to comply with all required follow-up exams.

Exclusion criteria

  • Patient has a dissecting aneurysm.
  • Patient has an acutely ruptured aneurysm.
  • Patient has an acute vascular injury.
  • Patient has a need for emergent surgery.
  • Patient has a known thoracic aortic aneurysm or dissection.
  • Patient has a mycotic aneurysm or has an active systemic infection.
  • Patient has unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina, or onset of prolonged angina).
  • Patient has had a myocardial infarction (MI) and/or stroke (CVA) within the past 6 months.
  • Patient has a major surgical or interventional procedure planned ≤30 days of the AAA repair.
  • Patient has history of connective tissue disease (e.g., Marfan's or Ehler's-Danlos syndrome).
  • Patient has history of bleeding disorders or refuses blood transfusions.
  • Patient has dialysis dependent renal failure or baseline serum creatinine level >2.0 mg/dl
  • Patient has a known hypersensitivity or contraindication to anticoagulation or contrast media that is not amenable to pre-treatment.
  • Patient has a known allergy or intolerance to polytetrafluoroethylene (PTFE), PEG-based polymers, fluorinated ethylene propylene (FEP) or nitinol.
  • Patient has a body habitus that would inhibit X-ray visualization of the aorta
  • Patient has a limited life expectancy of less than 1 year
  • Patient is currently participating in an investigational device or drug clinical trial.
  • Patient has other medical, social or psychological conditions that, in the opinion of the investigator, preclude them from receiving the pre-treatment, required treatment, and post-treatment procedures and evaluations.

Treatment and study plan

Ovation™/Ovation Prime™ Abdominal Stent Graft System

Device

Single occurence permanent implant of AAA device.

Primary outcomes

  1. Freedom From Aneurysm-Related Mortality at 5 Years

    Time frame: 5 Years

    The primary endpoint of the Ovation™/Ovation Prime™ Abdominal Stent Graft System study will be determined by evaluating freedom from aneurysm-related mortality at five (5) years. This will be compared to a target performance goal.

Secondary outcomes

  1. Composite Safety and Performance Endpoints

    Time frame: 1 Month & Annually 1 to 5 Years

    Serious Adverse Events (SAEs) within 30 days of the initial procedure and through 12 months and annually thereafter to 5 years

    At 30 days and 12 months and annually thereafter to 5 years, the following rates will be reported:

    • Mortality (AAA-related and all-cause)
    • Device patency
    • Conversion to open surgical repair
    • Endoleak
    • AAA enlargement
    • Stent Graft Migration
    • Device integrity
    • Secondary endovascular procedures
    • Aneurysm rupture

Sponsors and collaborators

Lead sponsor

TriVascular, Inc.

Industry

Registry information

Official study title

A Post-Market Approved (PMA) Post-Approval Study to Evaluate the Long-Term Safety and Effectiveness of the Ovation™/Ovation Prime™ Abdominal Stent Graft System

Important dates

Study start
2013
Primary completion
2020
Study completion
2020
First posted
Nov 11, 2013
Registry last updated
Jun 4, 2021