National Institutes of Health Clinical Center, 9000 Rockville Pike
Bethesda, Maryland, 20892, United States
NCT Number: NCT00924313
Background:
* Prostate cancers are difficult to see on most imaging studies such as X-rays, computed tomography (CT) scans, conventional magnetic resonance imaging (MRI) scans and conventional positron emission tomography (PET) scans. * An experimental radioactive tracer called 11C-acetate accumulates in prostate tumor cells and may help find prostate cancers more accurately than other imaging methods.
Objectives:
* To determine the accuracy of prostate tumor imaging using the tracer 11C-acetate.
Eligibility:
* Patients 18 years of age and older who are undergoing surgery for localized prostate cancer at the National Institutes of Health (NIH) Clinical Center.
Design:
* Patients have a positron emission tomography (PET scan). For this test, an intravenous (IV) line is placed in the patient's arm and the patient lies on a table inside the donut shaped scanner. (11)C-acetate is injected into the vein through the catheter and images of the lower pelvis and abdomen are obtained over 30 minutes. * Patients have an endorectal coil MRI scan. For this test, a tube is placed in the rectum, just behind the prostate, to increase the amount of signal received by the magnetic resonance (MR) unit. Other coils may be wrapped around the pelvis to further improve the quality of the scan. The patient lies on the scanning table for about 75 to 90 minutes while images are obtained. During the scan, a contrast agent called gadolinium is injected through an intravenous (IV) line to brighten the images.
Looking for future studies?
Notify Me18 year and older
Male
Interventional
Phase 1 / Phase 2
Bethesda, Maryland, 20892, United States
Background:
Objectives:
Primary Objective:
Secondary Objective:
Eligibility:
Design:
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Exclusion criteria
11C-acetate positron emission tomography (PET)/computed tomography (CT)for 30 minutes, intravenous bolus injection
Time frame: 2 years
Standard uptake values (SUV) measurements of 11C-acetate will be obtained in each sextant (e.g. region) on each patient. Sextant-specific malignancy will be determined pathologically based on a subsequent prostatectomy. Initially, on each patient, we will, average SUV measurements in tumor and non-tumor regions (i.e., sextants with malignancy and no malignancy, respectively). The patient average SUV measurements across tumors and non-tumor regions will then be compared using a paired t-test.
Time frame: 2 years
Here is the number of participants with adverse events. For the detailed list of adverse events see the adverse event module.
Time frame: 2 years
The diagnostic accuracy of 11C-Acetate PET/CT imaging in prostate cancer was compared with multi-parametric magnetic resonance imaging (MP-MRI) using sector based analysis, generating receiver-operating-characteristic (ROC) curves (plots of 1-specificity versus sensitivity) for both modalities.
Time frame: 2 years
Pelvic biodistribution was obtained for the prostate tumor, normal prostate and benign prostatic hyperplasia (BPH). Uptake is expressed in standardized uptake value (SUV).
Time frame: 2 years
Buildup of positron emission tomography (PET) radiopharmaceuticals excreted by the urinary system can accumulate in the bladder and limit pelvic imaging. This effect contributes to low physiologic distribution in the pelvis.
Time frame: 2 years
Suspicious lesions noted on biopsy were compared with standard care imaging diagnostic modalities, additional biopsies, and/or clinical follow up performed at the discretion of the referring physician.
Time frame: 2 years
Intensity [11C]AC uptake with histopathologic Gleason grade were done with a Spearman rank correlation following prostatectomy. Two biopsies were performed and graded according to tumor pattern. The two grades were added together for a final Gleason score. Gleason score equal to or less than 3+4 is considered low risk. Gleason score equal to or greater than 4+3 is considered high-risk.
Time frame: 2 years
PET/CT, MP-MRI, DW-MRI, and dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) were used to detect lesion sensitivity.
Time frame: 2 years
Tumor foci was histopathologically identified and tested to determine SUVmax relative to PSA levels. PSA normal range is 0-4ng/mL.
National Cancer Institute (NCI)
Nih
A Pilot Study of 11C-Acetate Positron Emission Tomography (PET) and 3 Telsa Magnetic Resonance Imaging (MRI) in Men With Prostate Cancer Undergoing Prostatectomy
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03269422
Genital Diseases, Genital Diseases, Male
Basking Ridge, New Jersey, United States
View Trial DetailsNCT05754658
Breast Cancer, Breast Diseases
Philadelphia, Pennsylvania, United States
View Trial DetailsNCT03606837
Genital Diseases, Genital Diseases, Male
Bordeaux, France
View Trial DetailsNCT06540794
Genital Diseases, Genital Diseases, Male
Istanbul, Turkey (Türkiye)
View Trial Details