Completed

NCT Number: NCT01790750

Pocket Echocardiography System (PES) for Detection of PDA in Neonates

This is a single-center, feasibility study involving all neonates admitted to the neonatal intensive care unit with orders for a cardiac echo evaluation. Parents will be approached and provided a description of the study. No written consent will be requested, but parents have the option of opting out. Each patient will have a 5 minute Pocket echocardiography system scan followed by a full echo performed on a traditional full featured echo system. The objective is to assess if the current Food and Drug administration (FDA) approved Pocket echocardiography system (PES) can detect patent ductus arteriosus (PDA) in neonates as comparable to traditional full featured echo systems (FFES) and/or physical exam alone.

Completed

Looking for future studies?

Notify Me

Key information

Age range

1 day–90 day

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

University of Florida

Gainesville, Florida, 32610, United States

About this study

All newborns admitted to the neonatal intensive care unit with orders for a cardiac echo evaluation will be included in this study. Parents will be approached and provided a description of the study. No written consent will be requested, but parents have the option of opting out. If parents agree to be part of this study, a 5-minute PES scan will be performed first so as to not bias the sonographer. Then, a full echocardiogram study will be performed on a traditional FFES. The scans will be performed at the bedside. The images will be reviewed and compared by fellow and/or attending and by experienced sonographer. The scans will include short axis view, ductal view and arch view.

The objective of the study is to assess if the current FDA approved PES can detect PDA in neonates as comparable to traditional full featured echo systems and/or physical exam alone. Using PES for PDA diagnosis will be an accessible, economic and effective way of complementing the findings in our physical exam by increasing diagnostic accuracy, and detecting PDA's at the bedside comparable to a full size traditional echocardiographic system.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • All newborn infants with orders for cardiac echocardiography evaluation in clinically stable condition

Exclusion criteria

  • Known congenital heart disease.
  • Clinically unstable (Meaning by unstable patients: Those patients that need cardiopulmonary resuscitation, or in maximum ventilatory or inotrope support and in immediate need for Extracorporeal Membrane Oxygenation or major surgery or whenever the physician attending responsible for the clinical care of the patient considers that a traditional echo needs to be done urgently)

Treatment and study plan

PES first, then FFES

Device

A 5-minute Pocket echocardiography system scan (PES) scan will be performed to detect PDA on neonates. This scan will be followed by a Full Featured Echocardiography System Scan (FFES) and scan results will be compared.

Other names: Pocket echocardiography system scan, Full Featured Echocardiography System Scan

Primary outcomes

  1. False Positives Results of Pocket Echocardiography System (PES) Detection of Patent Ductus Arteriosus (PDA) to Full Featured Echo System (FFES)

    Time frame: at baseline

    Evaluate the usefulness of the currently FDA approved Pocket Echocardiography System (PES) in PDA detection as compared to Full Featured Echo System (FFES) by looking at false positives between the two systems.

  2. False Negative Results of Pocket Echocardiography System (PES) Detection of Patent Ductus Arteriosus (PDA) to Full Featured Echo System (FFES)

    Time frame: at baseline

    Evaluate the usefulness of the currently FDA approved Pocket Echocardiography System (PES) in PDA detection as compared to Full Featured Echo System (FFES) by looking at false negatives between the two systems.

Sponsors and collaborators

Lead sponsor

University of Florida

Other

Registry information

Official study title

Pocket Echocardiography System (PES) for Detection of Patent Ductus Arteriosus (PDA) in Neonates

Important dates

Study start
2013
Primary completion
2013
Study completion
2013
First posted
Feb 13, 2013
Registry last updated
Apr 11, 2014

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.