Plantar Pressure Values in Patients With Ankylosing Spondylitis

this study was discovered that clinical and radiological characteristics were related to plantar pressure assessments in patients with AS.

Completed

Looking for future studies?

Notify Me

Key information

Sex eligibility

All sexes

Study type

Observational

About this study

Determine the correlation between the plantar pressure readings of AS patients and the clinical and radiological measures utilized in the monitoring of the condition.

Method: This study covered 75 participants. The quality of life was measured using ASQoL, BASMI, BASFI, and BASDAI, and demographic information was also recorded. The pedobarographic evaluations included the recording of static and dynamic plantar pressures

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

patients diagnosed with AS -

Exclusion criteria

Patients with cognitive dysfunction, vision loss that would prevent walking on the pedobarography platform, history of surgery and neurological deficit in the lower extremity, and patients who could not walk independently

-

Treatment and study plan

plantar pressure values

Diagnostic Test

Walking enables for extremely accurate and pointwise ground response force measurement because to plantar pressure measurement (pedobarography). It allows for the objective comparison and evaluation of the dynamic pressure put on the ground by the foot in contact with it. It is often used in clinics to assess foot mechanics and associated disorders that affect the foot sole. Additionally, plantar pressure analysis is useful for identifying, treating, and monitoring conditions that impact the lower extremity's axial alignment.

Primary outcomes

  1. Pedobarographic Measurements

    Time frame: at begining

    The cases' foot sole pressures were measured using a pedobarography device of the RsScan International brand (1m, 3D Scientific+Balance software model). This technology measures both static (when standing) and dynamic foot sole pressures (walking). The device's pressure measuring platform has an overall frame size of 1068x418x12 mm, 8192 sensors totaling 4 sensors per cm2, and a sensor area of 975x325 mm. It has a 500 Hz frequency, a 0-200 N/cm2 pressure range, a 15° to 40° C temperature range, and a 220/110 volt connecting power.

Sponsors and collaborators

Lead sponsor

Amasya University

Other

Registry information

Official study title

Plantar Pressure Values in Patients With Ankylosing Spondylitis and Their Relation With Clinical and Radiological Parameters

Important dates

Study start
2011
Primary completion
2012
Study completion
2012
First posted
Feb 16, 2023
Registry last updated
Feb 16, 2023

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.