Skip to main content
OpenTrials
Not Yet Recruiting

NCT Number: NCT07454980

Pivotal Trial to Evaluate TraNsvenous TrIcuspid Valve ReplacemenT With LuX-Valve Plus System (The TRINITY Pivotal Trial)

The goal of this clinical trial is to learn if LuX-Valve Plus system works to treat symptomatic subjects with at least severe tricuspid regurgitation (TR). It will also learn about the safety of LuX-Valve Plus system.

Researchers will compare LuX-Valve Plus system to a conventional device called EVOQUE to see if LuX-Valve Plus system works to treat subjects with at least severe tricuspid regurgitation.

Participants will:

Undergo one procedure using the LuX-Valve Plus system or EVOQUE after passing screening and enrolling in the trial; Complete follow-up visits and examinations as required by the trial protocol; Report any adverse events

Not Yet Recruiting

Trial opening soon.

Get Notified

Key information

Age range

21 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

For the randomized study:

  • Subject is at least 21 years of age at time of consent.
  • Subject (or legal guardian) understands trial requirements and treatment procedures and is able to provide written informed consent.
  • Severe or greater TR as assessed on transthoracic echocardiography by core lab.
  • New York Heart Association (NYHA) Class II-IV.
  • On optimal medical therapy (OMT) for TR at the time of baseline assessment per site Heart Team. OMT includes stable oral diuretic medications unless patient has a documented history of intolerance.
  • The site Heart Team concurs that the patient is a good candidate for transcatheter tricuspid valve replacement and suitable for LuX-Valve Plus system by core lab.
  • The commercial sponsor for EVOQUE deems that the patient is a good candidate for EVOQUE valve (control arm).

For single arm cohort ("Not Suitable for Conventional TTVI")

  • Meets all criteria 1-6 above
  • The EVOQUE commercial sponsor deems the anatomy unsuitable for EVOQUE tricuspid valve replacement, or the annular perimeter is smaller or greaterthan EVOQUE commercial Instructions for Use (IFU), as determined by the clinical site
  • Two independent Structural Cardiologists determine the patient "Not Suitable" for Triluminate edge to edge repair

Exclusion criteria

  • Left ventricular ejection fraction (LVEF) <35%.
  • Pulmonary arterial systolic pressure (PASP) >60 mmHg by echo Doppler (unless right heart catheterization [RHC] demonstrates PASP ≤60mmHg); in case RHC is performed, PASP >2/3 systemic BP with PVR >5 Wood units after vasodilator challenge, in the absence of symptomatic hypotension or systolic BP <90 mmHg.
  • Evidence of intracardiac mass, thrombus, or vegetation.
  • Ebstein Anomaly or congenital right ventricular dysplasia.
  • Surgical or interventional correction is indicated for other concomitant valvular diseases (subjects with concomitant valvular disease may treat their respective valve first and wait 2 months before being reassessed for the trial).
  • Subjects with valve prostheses implanted in the tricuspid valve.
  • Pre-existing prosthetic valve(s) (other than tricuspid ones) with clinically significant prosthetic dysfunction.
  • Active infection, infective endocarditis or sepsis within 3 months, or infections requiring antibiotics treatment within two weeks prior to planned procedure.
  • Untreated clinically significant coronary artery disease requiring revascularization.
  • Acute myocardial infarction or unstable ischemia-related angina within 30 days prior to the planned procedure.
  • Any percutaneous coronary, intracardiac or carotid intervention within 30 days prior to the planned procedure.
  • Cerebrovascular stroke (ischemic or bleeding) within 3 months prior to enrollment.
  • Active peptic ulcer or active gastrointestinal bleeding within 3 months prior to enrollment.
  • Blood dyscrasias as defined: leukopenia (WBC <1000 mm3), thrombocytopenia (platelet count <50,000 cells/mm3), history of bleeding diathesis, or coagulopathy.
  • Inability to tolerate anticoagulation or antiplatelet therapy.
  • Renal insufficiency (eGFR< 30ml/min [per the CKD-EPI formula] and/or renal replacement therapy).
  • Patients with hepatic insufficiency or cirrhosis with Child-Pugh score class C
  • Pregnancy or intent to become pregnant prior to completion of all protocol follow-up requirements.
  • Severe Chronic Obstructive Pulmonary Disease requiring steroids or requiring continuous home oxygen.
  • Untreatable hypersensitivity or contraindication to any of the following: all antiplatelets, all anticoagulants, nitinol alloys (nickel and titanium), bovine tissue, glutaraldehyde, or contrast media.
  • Estimated life expectancy <12 months.
  • Subjects currently participating in another clinical trial of an investigational drug or device that has not yet completed its primary endpoint.
  • Subjects with current history of illicit drug use.
  • Any other condition making it unlikely the patient will be able to complete all protocol procedure and follow-ups determined by the investigator.

Treatment and study plan

TTVI with LuX-Valve Plus System

Device

Transvenous tricuspid valve replacement with Lux-Valve Plus System in patients with severe or greater Tricuspid Regurgitation despite optimal medical therapy (OMT)

TTVI with EVOQUE

Device

Transvenous tricuspid valve replacement with EVOQUE in patients with severe or greater Tricuspid Regurgitation despite optimal medical therapy (OMT)

Primary outcomes

  1. Rate of Major Adverse Events (MAE)

    Time frame: 30 Day Post-Procedure

    Rate of Major Adverse Events (MAE) in experimental arm (LuX-Valve & EVOQUE) at 30 days consisting of the following components:

    • Cardiovascular Mortality
    • Myocardial Infarction (MI), periprocedural and spontaneous
    • All Stroke, disabling and non-disabling
    • New need for renal replacement therapy
    • Severe bleeding (includes type 3b or higher as defined by Tricuspid Valve Academic Research Consortium [TVARC]
    • Non-elective tricuspid valve re-intervention, surgery or transcatheter
    • Major access site and vascular complications
    • Major cardiac structural complications
    • Device-related pulmonary embolism
    • Arrhythmia and conduction disorders requiring permanent pacing
  2. Hierarchical composite endpoint: All-cause mortality, Heart failure hospitalization, and Tricuspid valve surgery or percutaneous intervention

    Time frame: 12 Months Post-Procedure

    Comparison of number of wins with composite endpoint events or improvement between experimental and active comparator arms

Study contacts

Contact information is provided by the study sponsor or research team.

Chen Jiao, MD

CONTACT

[email protected]

+86 13816576611

Sponsors and collaborators

Lead sponsor

Jenscare Innovation Inc.

Industry

Registry information

Official study title

Pivotal TRIal to Evaluate TraNsvenous TrIcuspid Valve ReplacemenT With Lux Valve Plus System in Patients With Severe or Greater Tricuspid Regurgitation - Clinical SafetY and Effectiveness

Important dates

Study start
2026
Primary completion
2029
Study completion
2038
First posted
Mar 6, 2026
Registry last updated
Mar 6, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.