Skip to main content
OpenTrials
Completed

NCT Number: NCT01437215

Pilot Study of the Endologix Fenestrated Stent Graft System

The purpose of this study is to determine whether the Endologix fenestrated stent graft system is safe and feasible in the endovascular repair of juxtarenal or pararenal aortic aneurysm.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Pontificia Universidad Católica de Chile, Santiago, Chile

Loading trial locations.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Informed consent understood and signed and pt agrees to all follow-up visits;
  • Abdominal aortic aneurysm with diameter ≥5cm or ≥4cm which has increased by 0.5cm or more in the past six months
  • Adequate iliac/femoral access compatible with the required delivery systems
  • Non-aneurysmal infrarenal aortic neck <15mm in length
  • Most caudal renal artery to aortoiliac bifurcation length at least 70mm
  • Proximal non-aneurysmal aortic neck below the SMA with: diameter 18 to 34 mm; length at least 15 mm; angle (clock face) <60° to the aneurysm sac;
  • Angle <60° (clock face) between the SMA and celiac artery
  • Renal arteries both distal to the SMA by 0-35mm, within 30mm of each other axially, with 4 to 8mm lumen diameter, and with clockface angle of 90° to 210° to each other
  • Iliac anatomy suitable for commercial bifurcated stent graft;
  • Minimum 3cm overlap achievable between fenestrated and bifurcated stent grafts

Exclusion criteria

  • Life expectancy <1 year as judged by the investigator;
  • Psychiatric or other condition that may interfere with the study;
  • Participating in the enrollment or 30-day follow-up phase of another clinical study;
  • Known allergy to any device component;
  • Coagulopathy or uncontrolled bleeding disorder;
  • Contraindication to contrast media or anticoagulants;
  • Ruptured, leaking, dissecting, or mycotic aneurysm;
  • Serum creatinine (S-Cr) level >2.0 mg/dL;
  • Traumatic vascular injury;
  • Active systemic or localized groin infection;
  • Connective tissue disease (e.g., Marfan's Syndrome);
  • Recent (within prior three months) cerebrovascular accident or myocardial infarction;
  • Prior renal transplant;
  • Length of either renal artery to be stented <13mm;
  • Significant occlusive disease or calcification of either renal artery;
  • An essential accessory renal artery;
  • Indispensable inferior mesenteric artery;
  • Untreated aneurysmal disease of the descending thoracic aorta;
  • Clinically significant mural thrombus circumferentially in the suprarenal segment;
  • Prior iliac artery stent implanted that may interfere with delivery system introduction;
  • Unsuitable vascular anatomy
  • Pregnancy (female patient of childbearing potential only)

Treatment and study plan

Ventana Fenestrated Stent Graft System

Device

Endovascular repair of juxtarenal or pararenal aortic aneurysm

Primary outcomes

  1. Safety - Number of Major Adverse Events (MAEs)

    Time frame: 30 Days

    Major Adverse Events = all cause death; bowel ischemia; myocardial infarction; paraplegia; renal failure; respiratory complications of stroke; blood loss >1000cc

  2. Feasibility- Number of subjects with procedural success (stent graft patency) and absence of type I/III endoleaks or migration

    Time frame: 30 Days

    Procedural Success with aortic/fenestrated and renal stent graft patency and absence of Type I/III endoleak or migration

Secondary outcomes

  1. Safety - Number of Major Adverse Events (MAEs)

    Time frame: >30 Days to 5 Years

    Major Adverse Events = all cause death; bowel ischemia; myocardial infarction; paraplegia; renal failure; respiratory complications of stroke; blood loss >1000cc

  2. Adverse Events

    Time frame: Procedurally to 5 Years

    All adverse events, whether serious or non-serious

  3. Distal Blood Flow

    Time frame: Discharge to 5 Years

    Ankle-brachial index measurements

  4. Renal Dysfunction

    Time frame: Discharge to 5 Years

    eGFR reduction >30% from baseline

  5. Device Performance

    Time frame: 30 Days to 5 Years

    Aortic, fenestrated, and renal stent graft integrity and patency; migration; endoleak; and aneurysm sac morphology

Sponsors and collaborators

Lead sponsor

Endologix

Industry

Registry information

Official study title

Prospective, Multicenter, Single Arm Feasibility and Initial Safety Study of the Endologix Fenestrated Stent Graft System for the Endovascular Repair of Juxtarenal/Pararenal (JAA/PAA) Aneurysms

Important dates

Study start
2010
Primary completion
2011
Study completion
2016
First posted
Sep 20, 2011
Registry last updated
Feb 16, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.