Effect of Trypan Blue on Corneal Endothelial Cell Count During Phacoemulsification
NCT07735000
Age Related Cataract, Cataract
Peshawar, KPK, Pakistan
View Trial DetailsNCT Number: NCT00067483
This study will use a new dynamic light scattering device (DLS), developed jointly by NASA and the NEI, to study pre-senile cataracts (cataracts that develop in patients 55 years old or less). Cataract is a clouding of the lens that interferes with the passage of light to the retinal, impairing visual acuity. DLS uses a low intensity laser light (similar to that used in supermarket checkouts) to measures lens cloudiness. It detects changes in the human lens at the earliest molecular stages of cataract development, when anti-cataract treatment would be most effective in reversing, delaying or preventing cataract formation.
Patients 55 years of age or younger with cataract may be eligible for this study. Candidates will be screened with the following tests and procedures:
* Medical history and physical examination. * Eye examination, including measurement of visual acuity (vision chart) and eye pressure; examination of pupils and eye movements; dilation of the pupils for examination of the lens and the back of the eye (retina). * Cataract photography using a camera with a bright flash to assess the status of the cataract and evaluate future changes. * Blood drawing if necessary for clinical care.
Participants will have a standard eye examination, as described above, plus DLS testing. For this procedure, the patient sits in front of the DLS device, with the chin placed on a chin rest. He or she fixes on a yellow-green target in the center of the camera lens. When the eye is properly aligned, the measurement is taken and the reddish light on the side of the camera lens turns on for 5 seconds. Measurements are taken on three layers of the lens. The procedure takes less than 30 minutes.
Participants will be followed at the NIH clinic once a month for up to 1 year to follow progression of the cataract. The visits will include a repeat of some of the exams listed above.
Looking for future studies?
Notify Me18 year–55 year
All sexes
Observational
National Institutes of Health Clinical Center, 9000 Rockville Pike, Bethesda, Maryland, United States
Recently, a device has been created to determine molecular interactions that occur in the human lens in vivo and non-invasively, called Dynamic Light Scattering Device (DLS). Preliminary studies have shown its potential in the detection of the earliest changes occurring in cataract, at the stage where anti-cataract treatment would theoretically be most effective in reversing, delaying or preventing cataracts. A new DLS device has been developed by NASA physicist Dr. Rafat Ansari using lower energy lasers, miniaturized and contained within a fiber optic tip, and further developed and tested under an NEI-NASA Inter Agency Agreement. We recently conducted a pilot study to evaluate the usefulness and reproducibility of this instrument for quantitating lens changes, and found good reproducibility. We also determined that a useful parameter is mean particle size. We therefore propose to use the new NEI-NASA DLS device to detect and study, non-invasively and in vivo, the earliest molecular cataractous changes that develop rapidly in the lenses of patients less than 55 years of age, otherwise called pre-senile cataracts.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Patients 55 years of age or younger with cataracts (pre-senile cataracts) will be admitted to this study.
Ten subjects who have cataracts and who are 55 years of age or younger, of either sex, will be recruited. DLS data will be obtained on the eye with no or little cataract every month for a year or until cataract surgery is required. AREDS grading will be utilized but will not be used as a protocol end point.
Exclusion criteria
Patients who have uveitis, glaucoma and who are thought to be at risk for an adverse reaction to pupil dilation, or have a history of allergic reaction to one of the dilating agents that will be used.
National Eye Institute (NEI)
Nih
Pilot Study on the Use of the NASA-NEI Dynamic Light Scattering (DLS) Device in Detecting Lens Changes in the Other Eye of Patients With Pre-Senile Cataracts
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07735000
Age Related Cataract, Cataract
Peshawar, KPK, Pakistan
View Trial DetailsNCT07605260
Cataract, Eye Diseases
Islamabad, Punjab Province, Pakistan
View Trial DetailsNCT06428955
Cataract, Eye Diseases
Indianapolis, Indiana, United States
View Trial DetailsNCT06111222
Cataract, Eye Diseases
Heidelberg, Germany
View Trial Details