The University of Texas Health Science Center at Houston
Houston, Texas, 77030, United States
Location status: Recruiting
Location contact
Carlos Artime, MD
CONTACT
Lauren M Nakazawa, MD
CONTACT
NCT Number: NCT05989880
The purpose of this study is to assess the feasibility of SafeLM as a primary airway device and as a conduit for intubation with and without the use of a bougie
Interested in participating?
Request Info18 year and older
All sexes
Interventional
Not applicable
Houston, Texas, 77030, United States
Location status: Recruiting
Carlos Artime, MD
CONTACT
Lauren M Nakazawa, MD
CONTACT
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The device will be inserted using the video capability and used as a primary airway device for the duration of the surgical procedure. Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening. The position of the device will be confirmed by observing the video image of the glottis on the monitor. The adequacy of ventilation and oxygenation will be assessed by monitoring the patient's end-tidal CO2, pulse oximetry, and clinical signs of effective ventilation. Leak and cuff pressure will be assessed. The device will be removed at the end of the surgical procedure or if there are any signs of device malfunction, airway obstruction, or inadequate ventilation.
The device will be blindly inserted without using the video capability and used as a primary airway device for the duration of the surgical procedure. Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening. The position of the device will be confirmed by observing the video image of the glottis on the monitor. The adequacy of ventilation and oxygenation will be assessed by monitoring the patient's end-tidal CO2, pulse oximetry, and clinical signs of effective ventilation. Leak and cuff pressure will be assessed. The video capability of the device will be used to assess the accuracy of placement after the fact. The device will be removed at the end of the surgical procedure or if there are any signs of device malfunction, airway obstruction, or inadequate ventilation.
The device will be inserted, and an endotracheal tube will be advanced through the device under direct visualization using the video capability of the device. Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening. The endotracheal tube will be introduced through the working channel of the SafeLM under direct visualization using the video capability of the device. The endotracheal tube will be advanced into the trachea, and the position will be confirmed by end-tidal carbon dioxide (EtCO2) detection and chest auscultation. The cuff of the endotracheal tube will be inflated, and mechanical ventilation will be resumed. The SafeLM device will be removed, and the position of the endotracheal tube will be confirmed once again.
The device will be inserted. Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening.The position of the device will be confirmed by observing the video image of the glottis on the monitor. The video camera on the SafeLM will be turned on to visualize the vocal cords.A standard airway bougie will be introduced through the working channel of the SafeLM under direct visualization using the video capability of the device.The SafeLM device will be removed, and an appropriately sized endotracheal tube will be advanced into the trachea. If a bougie is not able to be inserted into the tracheal under direct visualization, direct insertion of an endotracheal tube into the trachea will be attempted, followed by flexible scope intubation.
Time frame: at the time of intubation
This is assessed by the ability of the SafeLM to achieve adequate oxygenation and ventilation via the respective procedure once the airway device is in place.
Time frame: at the time of intubation
Time frame: at the time of intubation
This is measured by the time from opening the mouth to the time of end tidal CO2 on capnography
Time frame: at the time of intubation
Time frame: at the time of intubation
This will be assessed by the number of adverse events such as airway obstruction, aspiration, and hypoxia.
Time frame: at the time of intubation
This will be assessed by the number of adverse events such as esophageal intubation, bronchial intubation, and hypoxia during the intubation process.
Contact information is provided by the study sponsor or research team.
Carlos Artime, MD
CONTACT
Lauren M Nakazawa, MD
CONTACT
The University of Texas Health Science Center, Houston
Other
Pilot Feasibility Trial of the SafeLM Supraglottic Airway
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07660380
Anesthesia, Cough
Tianmen, Hubei, China
View Trial DetailsNCT05681572
Anesthesia, Anxiety Disorders
Montpellier, France
View Trial DetailsNCT07291388
Acute Pain, Anesthesia
Santiago, Santiago Metropolitan, Chile
View Trial DetailsNCT07685730
Anesthesia, Blockades Neuromuscular
Columbus, Ohio, United States
View Trial Details