Skip to main content
OpenTrials
Recruiting

NCT Number: NCT07019454

Physician Modified Endovascular Grafts for the Treatment of Elective, Symptomatic or Ruptured Juxtarenal Aortic Aneurysms

Patients who are found to have an aneurysm (bulge) in the abdominal aorta, which is the blood vessel in your abdomen (belly) that supplies blood to most of your lower body, including major organs and your legs. As an aneurysm expands, the walls of the aorta become weak and may rupture (break open), causing a major loss of blood with a high risk of serious problems and death. To avoid this risk, doctors repair aneurysms by either open surgery (incision) or endovascular surgery (covered stents to channel the blood flow). Juxtarenal aneurysms (those that come close to the kidney arteries) present a unique challenge as they are more dangerous to repair by open therapy and do not fit the standard approved endovascular devices. The purpose of this study is to assess the effects of the physician-modified endovascular graft (PMEG) by collecting information about the performance of this investigational medical device.

The main graft looks like a pair of pants with very short legs. The top of the pants is placed in the aorta. Then, two smaller grafts go from the main graft and to your iliac arteries (the main arteries supplying blood to your abdomen and legs) to form the legs of the pair of pants. Each graft is packed into a small catheter (a long, flexible plastic tube) that is placed into your aorta through the femoral artery in your groin (top of your leg). The grafts are then placed in the correct position in your aorta by releasing them from the catheters. These grafts are investigational because the research physician has changed them to match patient anatomy (body make up) while protecting blood flow to important vessels. Once the grafts are attached inside the aorta, they will support the area of the aorta that is weakened and bulging.

Modifications of the graft will include between one and four holes (fenestrations) near the top of the graft. The holes allow the graft to be located above the renal arteries (the blood vessels that supply blood to your kidneys) without blocking the blood flow to them. One or more of the arteries will also be treated with a stent (metal wire tube) to help keep the arteries open and to keep the arteries connected to the holes that are made for the graft.

The device is custom modified for patient specific anatomy. The information collected from this study will be used to show how well patients do when treated with the modified graft, both immediately after surgery and over a long period of time. After the procedure, labs, CT imaging with contrast, XRays and ultrasounds will be done to check the graft at intervals 1 month, 6 months, 12 months and yearly for 5 years. These are standard surveillance studies performed on any endovascular aneurysm repair.

Recruiting

Interested in participating?

Request Info

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Baystate Medical Center

Springfield, Massachusetts, 01199, United States

Location status: Recruiting

Location contact

Amanda Kravetz, MD

SUB_INVESTIGATOR

Avery Ching, MD

SUB_INVESTIGATOR

Erin Daley, MPH, BS

CONTACT

[email protected]

413-794-8704

Hazel Marecki, MD

CONTACT

[email protected]

413-794-0900

Hazel Marecki, MD

PRINCIPAL_INVESTIGATOR

Marc Norris, MD

SUB_INVESTIGATOR

Matthew Kronick, MD

SUB_INVESTIGATOR

Mohammad Ali, MD

SUB_INVESTIGATOR

Neal Hadro, MD

SUB_INVESTIGATOR

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patient is ≥ 18 years of age
  • Patients who are male or non-pregnant female (females of child bearing potential must have a negative pregnancy test prior to enrollment into the study)
  • Patient or Legally Authorized Representative has signed an Institutional Review Board (IRB) approved Informed Consent Form
  • Patient has a juxtarenal abdominal aortic aneurysm that meets at least one of the following:
  • An aneurysm with a maximum diameter of ≥ 5.5 cm for male (≥ 5.0 cm for female) or 2 times the normal diameter just proximal to the aneurysm using orthogonal (i.e., perpendicular to the centerline) measurements
  • Aneurysm with a history of growth > 0.5 cm in 6 months
  • Saccular aneurysm deemed at significant risk for rupture
  • Symptomatic aneurysm
  • Ruptured aneurysm
  • Patient has patent iliac or femoral arteries, with or without the use of conduit, that will allow endovascular access with the physician modified endovascular graft.
  • Patient has a suitable non-aneurysmal proximal aortic neck of ≥ 2 mm inferior to the most distal renal artery ostium.
  • Patient has a suitable non-aneurysmal distal iliac artery length (seal zone) of ≥ 15mm. The resultant repair should preserve patency in at least one hypogastric artery.
  • Patient has a suitable non-aneurysmal proximal aortic neck diameter between 20 and 32 mm, averaged across the diameters at the Celiac, SMA, at the lowest patent renal artery and at the midpoint of the renal arteries.
  • Patient has suitable non-aneurysmal distal common iliac diameters between 8 and 20 mm.
  • Patient has juxtarenal aortic neck angulation ≤ 60°
  • Target branch vessel diameter ≥ 5 mm.
  • Patient must be willing to comply with all required follow-up exams.

Exclusion criteria

  • Patient has a mycotic aneurysm or has an active systemic or local infection that may increase the risk of endovascular infection
  • Patient has unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina, or onset of prolonged angina)
  • Patient has a major surgical or interventional procedure, not related to the endovascular repair, planned within +/- 30 days of the AAA repair.
  • Patient has history of an aortopathic connective tissue disease (e.g. Marfan's or Ehler's- Danlos syndrome).
  • Patient has a known hypersensitivity or contraindication to anticoagulation or contrast media that is not amenable to pre-treatment.
  • Patient has known allergy or intolerance to stainless steel, nitiol, or gold (gold-plated tungsten)
  • Patient has a body habitus that would inhibit X-ray visualization of the aorta
  • Patient has a limited life expectancy of less than 1 year
  • Patient is currently participating in another investigational device or drug clinical trial
  • Patient has other medical, social or psychological conditions that, in the opinion of the investigator, preclude them from receiving the pre-treatment, required treatment, and post- treatment procedures and evaluations.
  • Thrombus or excessive calcification within the neck of the aneurysm
  • Branch vessel stenosis ≥ 80 %
  • Patients treatable on label with FDA approved EVAR or FEVAR device and can wait for device availability.
  • Subject is willing and eligible to enroll in a manufacturer-sponsored study at the investigational site, or the subject is willing and eligible to participate in a study with a manufacturer-made device at another institution.

Treatment and study plan

Physician Modified Endografting

Device

This is the only intervention in the study

Other names: PMEG

Primary outcomes

  1. Technical success

    Time frame: Periprocedural

    The physician was able to insert the delivery catheter and deliver the physician modified endovascular graft to the treatment site and preserve blood flow into the vessels intended to have blood flow preserved.

  2. Freedom from Type I and III Endoleaks at 12 months

    Time frame: 12 months post-procedure

    Yes/No Type I or Type III Endoleak visualized on 12 month CT Angiography

  3. Freedom from stent graft migration at 12 months

    Time frame: 12 months

    Yes/No stent migration at 12 months

  4. Freedom from aortic aneurysm enlargement at 12 months

    Time frame: 12 months

    Yes/No Freedom from enlargement maximal aortic diameter

  5. Freedom from aortic aneurysm rupture and conversion to open repair through 12 months

    Time frame: 12 months

    Yes/No freedom from

Secondary outcomes

  1. Mortality

    Time frame: 30 days, 6 months, 12 months, and annually through 5 years

    Yes/No

  2. Aneurysm related mortality

    Time frame: 30 days, 6 months, 12 months, and annually through 5 years

    Yes/ No

  3. Aneurysm Rupture

    Time frame: 30 days, 6 months, 12 months, and annually through 5 years

    Yes/ No

  4. Major Adverse Events

    Time frame: 30 days, 6 months, 12 months, and annually through 5 years

  5. Renal failure with or without permanent dialysis

    Time frame: 30 days, 6 months, 12 months, and annually through 5 years

    Yes/No, with or without dialysis

  6. Graft Infection

    Time frame: 30 days, 6 months, 12 months, and annually through 5 years

    Yes/ No

Study contacts

Contact information is provided by the study sponsor or research team.

Erin Daley, MPH, BS

CONTACT

[email protected]

413-794-8704

Hazel Marecki, MD

CONTACT

[email protected]

413-794-0900

Sponsors and collaborators

Lead sponsor

Baystate Medical Center

Other

Registry information

Official study title

Baystate Health Physician Sponsored - Investigational Device Exception: Physician Modified Endovascular Grafts for the Treatment of Elective, Symptomatic or Ruptured Juxtarenal Aortic Aneurysms

Important dates

Study start
2025
Primary completion
2030
Study completion
2035
First posted
Jun 13, 2025
Registry last updated
Jun 13, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.