Contrast-Enhanced Ultrasound
Diagnostic TestFollowing unenhanced (pre-contrast) ultrasound imaging of the target focal liver lesions (FLL), Sonazoid™ will be intravenously administered and a contrast-enhanced examination will be performed.
NCT Number: NCT06639828
Liver tumours, 40% of which are benign, account for 1% to 4% of all solid tumours in children. The benign tumours are mainly haemangiomas, liver hamartomas, and liver cell adenomas. The malignant tumours are mainly hepatoblastoma, hepatocellular carcinoma (HCC), malignant liver mesothelioma, and rhabdomyosarcoma. The differential diagnosis of liver masses in children is generally based on the child's age, the clinical evaluation (including alpha-fetoprotein test results), and imaging characteristics.
Liver tumours seldom produce clear symptoms and signs in the early stages, and they progress rapidly. As a result, most liver tumours are not diagnosed until the middle or late stages. To improve survival among patients with liver tumours, clinicians must find the liver tumours as early as possible and determine whether the tumours are benign or malignant. Conventional ultrasonography is commonly used for screening, and is preferred as the first-line imaging technique for children. Not only does it have a wide range of applications and a high diagnostic yield, but it is well accepted by patients and their parents. It can be performed in the examination room with the parents present, allowing real-time imaging and direct interaction with patient and parents.
CEUS is a non-invasive imaging technology that can continuously and dynamically observe blood perfusion in tumours in real-time through injection of a contrast agent to enhance the blood flow reflux signal in the human body. Consequently, CEUS is useful for visualising capillaries and tissue perfusion in the human body.
The purpose of this current study is to evaluate the use of Sonazoid™ perfluorobutane (PFB) microbubbles as a contrast medium for CEUS for evaluation of solitary liver masses in children.
Interested in participating?
Request InfoUp to 18 year
All sexes
Interventional
Phase 4
Munich University Hospital, München, Germany
This Phase 4, open-label, non-randomised, multicentre prospective study in Europe will enrol paediatric patients who are presenting with ≥1 confirmed untreated target FLL. This study plans to enrol at least 50 subjects at up to 12 centres in Europe. If a patient has multiple FLLs, the Investigator must select the target lesion at their discretion. Where possible, the target lesion should be a clearly visible and accessible lesion that could be easily followed during the non-CE ultrasound examination and all phases of the CEUS examination. The reference diagnosis/standard of truth for the target lesion of interest will be established by the principal investigators/sub-investigators on the basis of all available clinical information, including the results of biopsy, if available, and the dynamic CECT or CEMRI examination required for the study.
Following unenhanced (pre-contrast) ultrasound imaging of the target FLL, a single dose of Sonazoid™, dosed according to body weight (0.12 μL microbubbles/kg), will be intravenously administered to each patient, and a CEUS examination will be performed, with images acquired as specified in the Imaging Manual.
The unenhanced ultrasound and CEUS images will be assessed by 3 independent blinded readers following WFUMB-EFSUMB guidelines for adults, and in accordance with the Independent Review Charter. The diagnoses based on the unenhanced ultrasound and the CEUS results will be compared with the reference diagnosis/standard of truth for the target lesion. The diagnostic accuracy, sensitivity and specificity of the unenhanced ultrasound and CEUS images will then be calculated. Clinical safety data will be collected throughout the study. Safety will be evaluated by monitoring subjects for the occurrence of AEs.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Following unenhanced (pre-contrast) ultrasound imaging of the target focal liver lesions (FLL), Sonazoid™ will be intravenously administered and a contrast-enhanced examination will be performed.
Time frame: Images to be captured during the studies CEUS examination [approximately 5 seconds prior to bolus injection, up to 4-minutes post injection for the vascular phase] and blinded image evaluations shall be executed remotely at a central lab
Accuracy of the diagnosis based on the independent blinded read of the Sonazoid™-enhanced imaging for lesion differentiation (benign or malignant FLLs) during vascular phase imaging. The WFUMB-EFSUMB guidelines for interpreting CEUS of the liver in adults shall be used for interpreting the images and the subject's baseline diagnosis (well-established by CECT, CEMRI or biopsy) will be used as the reference diagnosis/standard of truth.
Time frame: Images to be captured during the studies CEUS examination [approximately 5 seconds prior to bolus injection, up to 4-minutes post injection for the vascular phase] and blinded image evaluations shall be executed remotely at a central lab
Sensitivity of the diagnosis based on the independent blinded read of the Sonazoid™-enhanced imaging for lesion differentiation (benign or malignant FLLs) during vascular phase imaging. The WFUMB-EFSUMB guidelines for interpreting CEUS of the liver in adults shall be used for interpreting the images and the subject's baseline diagnosis (well-established by CECT, CEMRI or biopsy) will be used as the reference diagnosis/standard of truth.
Time frame: Images to be captured during the studies CEUS examination [approximately 5 seconds prior to bolus injection, up to 4-minutes post injection for the vascular phase] and blinded image evaluations shall be executed remotely at a central lab
Specificity of the diagnosis based on the independent blinded read of the Sonazoid™-enhanced imaging for lesion differentiation (benign or malignant FLLs) during vascular phase imaging. The WFUMB-EFSUMB guidelines for interpreting CEUS of the liver in adults shall be used for interpreting the images and the subject's baseline diagnosis (well-established by CECT, CEMRI or biopsy) will be used as the reference diagnosis/standard of truth.
Time frame: Images to be captured during the studies CEUS examination [approximately 5 seconds prior to bolus injection, up to 4-minutes post injection for the vascular phase] and blinded image evaluations shall be executed remotely at a central lab.
Accuracy of the diagnosis (benign or malignant FLL) based on the Sonazoid™-enhanced imaging by vascular phase imaging, as compared with the unenhanced ultrasound imaging, when the baseline diagnosis is used as the reference standard.
Time frame: Images to be captured during the studies CEUS examination [approximately 5 seconds prior to bolus injection, up to 10-minutes post injection for the vascular and Kupffer phase(s)] and blinded image evaluations shall be executed remotely at a central lab
Accuracy of the diagnosis (benign or malignant FLL) based on the Sonazoid™-enhanced imaging by vascular phase and Kupffer phase imaging, as compared with the unenhanced ultrasound imaging, when the baseline diagnosis is used as the reference standard.
Time frame: Images to be captured during the studies CEUS examination [approximately 5 seconds prior to bolus injection, up to 4-minutes post injection for the vascular phase] and blinded image evaluations shall be executed remotely at a central lab.
Sensitivity of the diagnosis (benign or malignant FLL) based on the Sonazoid™-enhanced imaging by vascular phase imaging, as compared with the unenhanced ultrasound imaging, when the baseline diagnosis is used as the reference standard.
Time frame: Images to be captured during the studies CEUS examination [approximately 5 seconds prior to bolus injection, up to 10-minutes post injection for the vascular and Kupffer phase(s)] and blinded image evaluations shall be executed remotely at a central lab
Sensitivity of the diagnosis (benign or malignant FLL) based on the Sonazoid™-enhanced imaging by vascular phase and Kupffer phase imaging, as compared with the unenhanced ultrasound imaging, when the baseline diagnosis is used as the reference standard.
Time frame: Images to be captured during the studies CEUS examination [approximately 5 seconds prior to bolus injection, up to 4-minutes post injection for the vascular phase] and blinded image evaluations shall be executed remotely at a central lab.
Specificity of the diagnosis (benign or malignant FLL) based on the Sonazoid™-enhanced imaging by vascular phase imaging, as compared with the unenhanced ultrasound imaging, when the baseline diagnosis is used as the reference standard.
Time frame: Images to be captured during the studies CEUS examination [approximately 5 seconds prior to bolus injection, up to 10-minutes post injection for the vascular and Kupffer phase(s)] and blinded image evaluations shall be executed remotely at a central lab
Specificity of the diagnosis (benign or malignant FLL) based on the Sonazoid™-enhanced imaging by vascular phase and Kupffer phase imaging, as compared with the unenhanced ultrasound imaging, when the baseline diagnosis is used as the reference standard.
Time frame: Images to be captured during the studies CEUS examination [approximately 5 seconds prior to bolus injection, up to 4-minutes post injection for the vascular phase] and blinded image evaluations shall be executed remotely at a central lab.
The difference in the diagnostic confidence for the unenhanced ultrasound imaging and that for the Sonazoid™-enhanced ultrasound imaging based on the vascular phase. The difference in the diagnostic confidence will ranged from -3 to 3, higher scores mean better outcome.
Time frame: From administration of Sonazoid, up to 4 hours for in-person monitoring followed by 24-hour and 72-hour telephone follow ups
Number and percentage of subjects with Treatment-emergent adverse events, defined as adverse events that occurred at any timepoint from the administration of Sonazoid™ to the end of the study (72 hours after Sonazoid™ administration)
Time frame: From administration of Sonazoid, up to 4 hours for in-person monitoring followed by 24-hour and 72-hour telephone follow ups
Number and percentage of subjects with drug-related Treatment-emergent adverse events
Time frame: From administration of Sonazoid, up to 4 hours for in-person monitoring followed by 24-hour and 72-hour telephone follow ups
Number and percentage of subjects with Treatment-emergent Serious Adverse events
Time frame: Pre-administration of Sonazoid and 4 hours post administration
Number and percentage of subjects with changes in physical examination status (normal/abnormal)
Time frame: Pre-administration of Sonazoid and 4 hours post administration
Summary statistics of systolic/diastolic blood pressure, heart rate, respiratory rate, body temperature, and oxygen saturation for each timepoint
Time frame: Pre-administration of Sonazoid and 4 hours post administration
Summary statistics of clinical laboratory for each timepoint
Contact information is provided by the study sponsor or research team.
David Thompson
CONTACT
Tingting Wang
CONTACT
GE Healthcare
Industry
A Phase 4, Open-Label, Non-randomised, Multicentre Study to Evaluate Safety and Efficacy of Intravenous Administration of Sonazoid™ for Contrast-Enhanced Ultrasound Liver Imaging in Paediatric Patients
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT00243633
Digestive System Diseases, Digestive System Neoplasms
Angers, France
View Trial DetailsNCT00781924
Focal Lesions in the Abdomen, Focal Liver Lesions
Copenhagen, Denmark
View Trial Details