Icon Clinical Pharmacology Unit, Llc
Omaha, Nebraska, 68154, United States
NCT Number: NCT01439204
The purpose of this study is to determine whether the blood levels of Abatacept (BMS-188667) drug product manufactured at Lonza Biologics and the Devens, MA facility of Bristol-Myers Squibb are comparable in healthy subjects
Looking for future studies?
Notify Me18 year–55 year
All sexes
Interventional
Phase 1
Omaha, Nebraska, 68154, United States
Primary Purpose of this study is to compare the pharmacokinetic (PK) of Abatacept (BMS-188667) manufactured at Lonza relative to Abatacept (BMS-188667) manufactured at Devens, MA facility following a single intravenous infusion of 750 mg in healthy subjects
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Solution for injection, Intravenous, 750 mg, Single dose, 1 day,
Other names: BMS-188667
Time frame: Days 1 to 71
Cmax was derived from serum concentration versus time data. Serum samples were analyzed for abatacept by a validated enzyme-linked immunosorbent assay (ELISA) and were obtained at: predose (0 hours), 0.25 hours (h), 0.5, 1, 2, 6, 12, 24, 72, 168, 336, 504, 672, 1008, 1344, and 1688 h post dose (Days 1 to 71). The results were summarized. The lower limit of assay quantitation (LLOQ) was 1.00 nanograms per milliliter (ng/mL). Cmax was measured in micro grams per milliliter (µg/mL).
Time frame: Day 1 to Day 71
Tmax was derived from serum concentration versus time data. Serum samples were analyzed for abatacept by a validated enzyme-linked immunosorbent assay (ELISA) and were obtained at: predose (0 hours), 0.25 hours (h), 0.5, 1, 2, 6, 12, 24, 72, 168, 336, 504, 672, 1008, 1344, and 1688 h post dose (Days 1 to 71). The results were summarized. The lower limit of assay quantitation (LLOQ) was 1.00 nanograms per milliliter (ng/mL). Tmax was measured in hours (h).
Time frame: Day 1 to Day 71
AUC (0 - 28) was derived from serum concentration versus time data. Serum samples were analyzed for abatacept by a validated enzyme-linked immunosorbent assay (ELISA) and were obtained at: predose (0 hours), 0.25 hours (h), 0.5, 1, 2, 6, 12, 24, 72, 168, 336, 504, 672, 1008, 1344, and 1688 h post dose (Days 1 to 71). The results were summarized. The lower limit of assay quantitation (LLOQ) was 1.00 nanograms per milliliter (ng/mL). AUC (0 - 28) was measured in micro grams*hours per milliliter (µg*h/mL).
Time frame: Day 1 to Day 71
AUC (0 - T) was derived from serum concentration versus time data. Serum samples were analyzed for abatacept by a validated enzyme-linked immunosorbent assay (ELISA) and were obtained at: predose (0 hours), 0.25 hours (h), 0.5, 1, 2, 6, 12, 24, 72, 168, 336, 504, 672, 1008, 1344, and 1688 h post dose (Days 1 to 71). The results were summarized. The lower limit of assay quantitation (LLOQ) was 1.00 nanograms per milliliter (ng/mL). AUC (0 - T) was measured in micro grams*hour per milliliter (µg*h/mL).
Time frame: Day 1 to Day 71
AUC (0 - INF) was derived from serum concentration versus time data. Serum samples were analyzed for abatacept by a validated enzyme-linked immunosorbent assay (ELISA) and were obtained at: predose (0 hours), 0.25 hours (h), 0.5, 1, 2, 6, 12, 24, 72, 168, 336, 504, 672, 1008, 1344, and 1688 h post dose (Days 1 to 71). The results were summarized. The lower limit of assay quantitation (LLOQ) was 1.00 nanograms per milliliter (ng/mL). AUC (0 - INF) was measured in µg*h/mL.
Time frame: Day 1 to Day 71
T-HALF was derived from serum concentration versus time data. Serum samples were analyzed for abatacept by a validated enzyme-linked immunosorbent assay (ELISA) and were obtained at: predose (0 hours), 0.25 hours (h), 0.5, 1, 2, 6, 12, 24, 72, 168, 336, 504, 672, 1008, 1344, and 1688 h post dose (Days 1 to 71). The results were summarized. The lower limit of assay quantitation (LLOQ) was 1.00 nanograms per milliliter (ng/mL). T-HALF was measured in hours (h).
Time frame: Day 1 to Day 71
CLT was the volume of abatacept cleared by the system, normalized by baseline body weight. Serum samples were analyzed for abatacept by a validated enzyme-linked immunosorbent assay (ELISA) and were obtained at: predose (0 hours), 0.25 hours (h), 0.5, 1, 2, 6, 12, 24, 72, 168, 336, 504, 672, 1008, 1344, and 1688 h post dose (Days 1 to 71). The results were summarized. The lower limit of assay quantitation (LLOQ) was 1.00 nanograms per milliliter (ng/mL). CLT was measured in milliliters per hours per kilogram of body weight (mL/h/kg).
Time frame: Day 1 to Day 71
Vss was derived from serum concentration versus time data. Serum samples were analyzed for abatacept by a validated enzyme-linked immunosorbent assay (ELISA) and were obtained at: predose (0 hours), 0.25 hours (h), 0.5, 1, 2, 6, 12, 24, 72, 168, 336, 504, 672, 1008, 1344, and 1688 h post dose (Days 1 to 71). The results were summarized. The lower limit of assay quantitation (LLOQ) was 1.00 nanograms per milliliter (ng/mL). Vss was measured in liters per kg body weight (L/kg).
Time frame: Days 29, 57, 71
Immunogenicity determination was based on titers of anti-abatacept and anti- cytotoxic T-lymphocyte-associated antigen-4 (CTLA-4-T) antibodies in serum over time. A participant had a positive abatacept-induced immunogenicity if 1 of the following criteria were met: missing baseline measurement and a positive response after baseline; negative baseline response and positive response after baseline; a baseline response and a positive response after baseline that has a titer value strictly greater than the baseline titer value. A validated, sensitive, electrochemiluminescence assay (ECL) method was used to analyze the antibodies in serum. Samples confirmed positive with ECL and with abatacept serum concentrations of less than equal to 1 µg/mL were further analyzed with a validated, in vitro, cell-based bioassay to analyze the sera containing the abatacept neutralizing activity. Samples obtained on Days 29, 57 and 71 post dose of abatacept on Day 1 (baseline).
Time frame: Day 2 to Day 71
Blood samples obtained: Days 1, 2, 4, 8, 15, 22, 29, 43, 57 and 71. International Units per liter (U/L); milligram per deciliter (mg/dL); Male(M); Female (F). Reference ranges (low/high) for laboratories for which participants were identified with marked abnormalities during the study: Blood Urea Nitrogen (M/F) 10-20mg/dL ; Creatine Kinase (F) 21-21 U/L,(M) 32-294 U/L; Direct Bilirubin (M/F) 0.1-0.4 mg/dL ; Fasting Glucose (M/F) 70-110 mg/dL; Lactate Dehydrogenase (M/F) 110-209 U/L.
Time frame: Day 2 to Day 72
Blood samples obtained: Days 2, 4, 8, 15, 22, 29, 43, 57 and 71. Male(M); Female (F). Reference ranges (low/high) for laboratory parameters for which participants were identified with marked abnormalities during the study: Leukocytes (quantitative White blood cells) (M/F) 4-11*10^3/microliters (µL); Neutrophils (absolute)(M/F) 1.4- 8.2*10^3/µL.
Time frame: Day 1 to Day 71
Blood pressure was obtained while the participant had been quietly seated for at least 5 minutes. Baseline was the 0 hour measurement on Day 1 (day of dosing) or if this value was missing, the last measurement before dosing. Blood pressure was measured in millimeters of mercury (mmHg) on Days 1, 2, 15, 29, 57, and 71.
Time frame: Day 1 to Day 71
Blood pressure was obtained while the participant had been quietly seated for at least 5 minutes. Baseline was the 0 hour measurement on Day 1 (day of dosing) or if this value was missing, the last measurement before dosing. Blood pressure was measured in millimeters of mercury (mmHg) on Days 1, 2, 15, 29, 57, and 71.
Time frame: Day 1 to Day 71
12-lead electrocardiograms were performed on a supine participant (5 minutes supine) at baseline (baseline = screening; Days -21 to -2) and at Day 71. QT interval and QTc were measured in mille seconds (msec). A change from baseline QT and QTc (corrected for heart rate by Fridericia formula) greater than (>) 30 msec or less than (<) 60 msec were presented, as well as values over 450 and 500 msec. QT interval on ECG image defined as: time from the beginning of the QRS (complex consisting of Q, R and S waves) to the end of the T wave.
Bristol-Myers Squibb
Industry
A Randomized, Open-label, Parallel-Group, Single-dose, Biocomparability Study of the Pharmacokinetics of Abatacept (BMS-188667) Drug Products Using Active Pharmaceutical Ingredient Manufactured at Devens, MA Site Relative to Active Pharmaceutical Ingredient Manufactured at Lonza, New Hampshire (NH) in Healthy Subjects
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03649178
Arthritis, Arthritis, Rheumatoid
Nashville, Tennessee, United States
View Trial DetailsNCT03025308
Arthritis, Arthritis, Rheumatoid
Huntsville, Alabama, United States
View Trial DetailsNCT07715045
Arthritis, Arthritis, Rheumatoid
Palembang, South Sumatera, Indonesia
View Trial DetailsNCT00055055
Arthritis, Arthritis, Rheumatoid
Bethesda, Maryland, United States
View Trial Details