Skip to main content
OpenTrials
Recruiting

NCT Number: NCT05179616

Pforzheim Tricuspid Valve Registry - Outcomes of Percutaneous Tricuspid Valve Repair

The Pforzheim Tricuspid Valve Registry study is designed to confirm the safety and performance of the TriClip™ device in a contemporary real-world setting in critically ill patients. The observational trial is a prospective, single arm, open-label, single-center, post market registry.

Recruiting

Interested in participating?

Request Info

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Helios Klinikum Pforzheim

Pforzheim, 75175, Germany

Location status: Recruiting

Location contact

Alexandru Patrascu, MD

CONTACT

[email protected]

+491736964480

About this study

Significant tricuspid regurgitation is a common finding in elderly patients, with an incidence of 5.6% after the age of 70 years, according to the Framingham Heart Study. TR is an independent predictor for adverse prognosis and has limited treatment options. Tricuspid valve (TV) intervention is indicated when symptomatic TR-related right heart failure (RHF) is present. However, the surgical risk is usually deemed to be too high due to the presence of advanced age, pulmonary hypertension, right ventricular (RV) impairment, major organ failure and other co-morbidities. Moreover, isolated tricuspid valve surgery has an in-hospital mortality of approx. 8,7%, according to recent data.

High TR prevalence, coupled with low incidence of isolated TV surgery, has created a considerable population in need of alternative, percutaneous therapies to improve outcomes. Recently, a variety of interventional procedures and devices have been developed which simulate different surgical approaches like suture or ring annuloplasty, coaptation enhancement, neochordae repair, or even valve replacement. Among them, coaptation devices attempt to correct leaflet malcoaptation by using the edge-to-edge clip technique, similar to treatment of functional mitral regurgitation. To date, most TTVR interventions have been performed off-label with the MitraClip device.

Last year, the first TR dedicated device (TriClipTM, Abbott Medical) has been approved (CE mark), after showing good feasibility, safety and effectiveness, and meanwhile sustained and marked clinical benefit with low mortality after 12 months.

Although most TTVR studies have enrolled high-risk cohorts, criteria for patient selection and timing of intervention have yet to be defined. Based on scientific surgical data, it seems reasonable to expect poorer outcomes in patients with several comorbidities, advanced cardiac remodeling and RHF-related major organ dysfunction e.g., renal and hepatic function impairment. Whether or not this assumption can be extrapolated to TTVR needs to be investigated.

In this registry, the investigators aim to evaluate if percutaneous therapy with the TriClip system is safe and effective in patients at high and prohibitive risk and wether or not procedural success is the main determinant of short-, mid- and long-term outcomes.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Subjects (>=18 years age) have severe tricuspid regurgitation and are symptomatic despite medical therapy.
  • Subjects eligible to receive the TriClip™
  • Subjects must provide written informed consent prior to study procedure.

Exclusion criteria

  • Subjects participating in another clinical study that may impact the follow-up or results of this study.

Treatment and study plan

Transcatheter edge-to-edge tricuspid valve repair

Procedure

Percutaneous edge to edge repair of tricuspid valve using the TriClip system

Primary outcomes

  1. Procedural Success

    Time frame: at 12 months

    One-grade reduction of tricuspid regurgitation

Secondary outcomes

  1. Change in quality of life

    Time frame: at 12 months

    NYHA class

  2. Change in functional capacity

    Time frame: at 12 months

    6-minute walk test

  3. Major organ system functional change

    Time frame: at12 months

    Renal and hepatic function as assessed by following lab values: creatinine, glomerular filtration rate, aspartate transaminase, alanine aminotransferase and bilirubine

Study contacts

Contact information is provided by the study sponsor or research team.

Alexandru Patrascu, MD

CONTACT

[email protected]

+491736964480

Ilka Ott, MD, PhD

CONTACT

[email protected]

+4972319692955

Sponsors and collaborators

Lead sponsor

Helios Klinikum Pforzheim

Other

Registry information

Official study title

Pforzheim Tricuspid Valve Registry: A Real-world Observational Trial Evaluating Outcomes in Patients Treated With the Abbott TriClip™ Device in Helios Klinikum Pforzheim

Important dates

Study start
2020
Primary completion
2025
Study completion
2026
First posted
Jan 5, 2022
Registry last updated
Sep 22, 2023

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.