Skip to main content
OpenTrials
Not Yet Recruiting

NCT Number: NCT07370883

Personalized Selection of Hyperangulated vs. Macintosh Videolaryngoscope Blades

This study aims to determine whether hyperangulated blades have a higher intubation success rate than Macintosh blades in patients undergoing general anesthesia, and to identify patient subgroups in which hyperangulated blades are particularly advantageous for tracheal intubation.

Not Yet Recruiting

Trial opening soon.

Get Notified

Key information

Conditions

Age range

19 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

About this study

Randomized controlled trial

This study was designed as a randomized controlled trial. A total of 524 patients were randomly allocated in a 1:1 ratio to either the hyperangulated blade group (H group) or the Macintosh blade group (M group).

The primary endpoint was first-attempt intubation success. The secondary endpoints included the overall tracheal intubation success rate, the number of intubation attempts, time for the tracheal tube to pass through the vocal cords (T5), time to ventilation (T6), and the use of adjunctive airway maneuvers (e.g., external laryngeal manipulation [ELM]).

Between-group comparisons were performed according to the characteristics of each endpoint. Categorical variables were analyzed using the χ² test or Fisher's exact test, as appropriate, and results were presented as risk ratios (RRs) with 95% confidence intervals (CIs). Continuous variables were assessed for normality using the Shapiro-Wilk test. Normally distributed variables were compared using the independent-samples t-test, whereas non-normally distributed variables were analyzed using the Mann-Whitney U test. Results were reported as mean or median differences with 95% CIs.

All study participants experienced both videolaryngoscope blades. However, actual tracheal intubation was performed only with the second blade, while the first blade was used solely for assessment of glottic view and approach times. To minimize learning-related order effects, each attempt was performed by a different investigator, and each investigator was restricted to using only the blade assigned to them. In addition, within-patient comparisons of POGO scores, approach times, and visualization difficulty between the first and second blades were conducted to analyze blade-specific visualization characteristics. If significant differences were observed, potential order effects were further evaluated during the analysis.

Within-patient comparison (paired evaluation)

Before actual tracheal intubation, glottic visualization up to just before the vocal cords was assessed using both blades in all participants. The order of blade use was balanced according to randomization: patients in the M group underwent visualization assessment in the H→M sequence followed by intubation with the Macintosh blade, whereas patients in the H group underwent visualization assessment in the M→H sequence followed by intubation with the hyperangulated blade. Accordingly, within-patient comparisons were conducted using visualization data obtained in the predefined sequence for each group, thereby minimizing order effects.

The evaluated parameters included:

(i) time to obtain a laryngeal view (T1/T3), (ii) time for the tracheal tube tip to reach the vocal cords (T2/T4), (iii) VIDIAC score, (iv) percentage of glottic opening (POGO) score, (v) operator-reported subjective difficulty score, and (vi) complications (e.g., SpO₂ < 90%, dental or soft-tissue injury).

Differences in continuous paired outcomes between the hyperangulated and Macintosh blades were analyzed using the paired t-test or Wilcoxon signed-rank test, as appropriate. When classifying each outcome according to which blade was superior (hyperangulated-favored, Macintosh-favored, or equivalent), McNemar's test was used for binary classifications and the Stuart-Maxwell test for three-category classifications.

Machine learning-based exploratory analysis

Finally, data obtained from the randomized controlled trial and paired analyses were further leveraged to explore, in an exploratory manner, which blade may be more advantageous under specific anatomical and demographic conditions. Outcomes that demonstrated between-group differences in the primary or secondary analyses were selected as target variables. All covariates were included as input features, and an XGBoost-based ensemble tree model was trained.

Model performance was evaluated using the area under the receiver operating characteristic curve (AUROC) with 95% CIs for binary outcomes and root mean squared error (RMSE) and mean absolute error (MAE) for continuous outcomes. SHapley Additive exPlanations (SHAP) analysis was performed to visualize feature importance and interaction patterns, and decision curve analysis (DCA) was used to assess the clinical net benefit of the predictive models.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Adult patients aged ≥ 19 years undergoing surgery under general anesthesia.

Exclusion criteria

  • Patients who did not provide informed consent
  • Patients with severely loose or unstable teeth
  • Patients with cervical spine disease
  • Patients with American Society of Anesthesiologists (ASA) physical status class IV or higher
  • Pregnant women
  • Patients with head and neck cancer
  • Patients who had previous radiotherapy for head and neck cancer
  • Patients deemed unsuitable for study participation at the investigator's discretion

Treatment and study plan

Macintosh group

Device

tracheal intubation was performed using a standard Macintosh-type videolaryngoscope blade

hyperangulated group

Device

tracheal intubation was performed using a hyperangulated videolaryngoscope blade

Primary outcomes

  1. first attempt success rate

    Time frame: At the time of tracheal intubation (up to 10 min)

    successful placement of the tracheal tube into the airway on the first attempt within 60 seconds, without the need for assistance from another operator or the use of adjunctive airway maneuvers.

Secondary outcomes

  1. Preoperative airway assessment included the modified Mallampati classification

    Time frame: before intubation (up to 10 min)

    Class I: soft palate, fauces, pillars, and uvula visible; Class II: soft palate, fauces, and uvula visible; Class III: soft palate and base of the uvula visible; Class IV: soft palate not visible

  2. overall tracheal intubation success rate

    Time frame: At the time of tracheal intubation (up to 10 min)

    overall tracheal intubation success rate

  3. the number of attempts required to achieve successful intubation

    Time frame: At the time of tracheal intubation (up to 10 min)

    the number of attempts required to achieve successful intubation

  4. the use of adjunctive airway maneuver

    Time frame: At the time of tracheal intubation (up to 10 min)

    the use of adjunctive airway maneuvers, such as external laryngeal manipulation (ELM)

  5. time to obtain a laryngeal view with the first blade

    Time frame: At the time of tracheal intubation (up to 10 min)

    T1: from insertion of the laryngoscope to visualization of the glottis

  6. time for the tracheal tube to reach the vocal cords with the first blade

    Time frame: At the time of tracheal intubation (up to 10 min)

    T2: from laryngoscope insertion to advancement of the tube to just before the vocal cords

  7. time to obtain a laryngeal view with the second blade

    Time frame: At the time of tracheal intubation (up to 10 min)

    T3: from laryngoscope insertion to visualization of the glottis

  8. time for the tracheal tube to reach the vocal cords with the second blade

    Time frame: At the time of tracheal intubation (up to 10 min)

    T4: from laryngoscope insertion to advancement of the tube to just before the vocal cords

Sponsors and collaborators

Lead sponsor

Seoul National University Hospital

Other

Registry information

Official study title

Personalized Selection of Hyperangulated vs. Macintosh Videolaryngoscope Blades: Randomized Controlled Trial and Development of an Integrated Predictive Algorithm

Acronym: HAVL

Important dates

Study start
2026
Primary completion
2026
Study completion
2027
First posted
Jan 27, 2026
Registry last updated
Jan 28, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.