Door handle device
DeviceTo evaluate the cylindrical grip movement, it was used a door handle, which evaluated all the strength at the arc of motion
NCT Number: NCT02965352
This study has developed a peripheral to quantify the functional strength of children without motor change during the movement of grip and pinch. It was possible to know the exact values of these strengths, the range of motion that was made, and also if the grip strength was maintained during all the arc of motion.
Looking for future studies?
Notify Me7 year–10 year
All sexes
Interventional
Not applicable
Since childhood, it has been necessary to produce sufficient force to grip and pinch, for performing daily tasks independently; therefore, measurements of these forces end up being useful markers to evaluate the performance and the physical development of the child. It was developed a peripheral containing three devices and instrumented for analyzing the force applied during execution of the cylindrical grip movement, pinch pulp-side and pinch pulp-pulp in different situations of the daily life of the volunteer. The data acquisition interface was developed in a software for data recording. For the peripheral functionality tests, thirty volunteers of both genders were selected. They were also students of the Sports Secretary, with no motor abnormalities, between seven and ten years old.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
To evaluate the cylindrical grip movement, it was used a door handle, which evaluated all the strength at the arc of motion
To evaluate the pulp-pulp pinch movement, it was used one linear switch, which evaluated all the strength at the motion displacement.
To evaluate the pulp-side pinch movement, it was used a door key, which evaluated all the strength at the arc of motion
Time frame: 15 minutes
The force of cylindrical grip movement was measured through a door handle device, pinch pulp-side through a door key and pinch pulp-pulp movement through a switch. The test was measured 3 times with 1 minute interval and it was measured the strength during all arc of motion. Unit of measurement: Newton (N).
Time frame: 15 minutes
The test measured the range of motion in a door handle device and in a door key device 3 times with 1 minute interval for each test, in which all the range of motion was measured from its start until its end. Unit of measurement: Angle (º).
Time frame: 15 minutes
The test measured the range of motion in a linear switch device 3 times with 1 minute interval for each test, in which all of the range of motion was measured from its start until its end. Unit measurement: Percentage (%).
University of Mogi das Cruzes
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07203066
Colonic Diseases, Colorectal Neoplasms
Istanbul, Turkey (Türkiye)
View Trial DetailsNCT05829707
Breast Cancer Female, Breast Diseases
View Trial DetailsNCT04911712
Body Mass Index, Hand Strength
Jakarta Pusat, DKI Jakarta, Indonesia
View Trial DetailsNCT02946502
Hand Strength, Pathologic Processes
Clamart, France
View Trial Details