Mario Pérez Sayáns
Santiago de Compostela, A Coruña, 15785, Spain
NCT Number: NCT03796494
This is a randomized, single-blind, split-mouth clinical trial to evaluate the performance of peri-implant tissues (bone and soft tissues) in conventionally loaded Galimplant implants, using a classic multi-position, anti-rotational abutment, comparing it to the new multi-abutment aesthetic slim anti-rotational placed both at the time of the implant surgery. To this end, 80 Galimplant implants with a diameter of 4 mm and 10 mm in length will be placed in areas of mature scarred post-extraction bone. Patients be divided into 2 study groups, group C: straight pillar; Group T: Slim pillar. The bone and clinical radiological stability of the peri-implant tissues will be evaluated at 6 weeks post-surgery and at 6-12-24 months post-prosthetic loading.
Looking for future studies?
Notify Me20 year and older
All sexes
Interventional
Not applicable
Santiago de Compostela, A Coruña, 15785, Spain
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
This is the classic abutment, straight and anti-rotational for dental implants which have been tested before
This is the new concept of the prostheses abutment, slim and anti-rotational to improve the width of biologic space
Time frame: 10 months
Randomly and following the inclusion and exclusion criteria, the implants will be placed with the normal preparation protocol. Investigators will evaluate the immediate post-surgical stability of implants and peri-implant tissues through the Ostell system, based on the resonance frequency analysis (RFA). The implant stability quotient (ISQ) is the value on a scale that indicates the level of stability and osseointegration in dental implants. The scale ranges from 1 to 100, with higher values indicating greater stability. The acceptable stability range lies between 55-85 ISQ
Time frame: 1 day
Randomly and following the inclusion and exclusion criteria, the implants will be placed with the normal preparation protocol. We will load the crowns 8 weeks after implant surgery. Investigators will evaluate the stability at different moments, 8 weeks, 6 months, 12 months and 24 months. The implant stability quotient (ISQ) is the value on a scale that indicates the level of stability and osseointegration in dental implants. The scale ranges from 1 to 100, with higher values indicating greater stability. The acceptable stability range lies between 55-85 ISQ. ISQ values are obtained using resonance frequency analysis (RFA).
Time frame: 1 day
At the moment of placing the implant, clinical variables will be evaluated: depth of probing (distance from the peri-implant margin to the most depth of the peri-implant sulcus). This will be the basal measure of the implant stability and peri-implant tissue levels. Investigators will calculate the difference between the basal measure and the future measurements.
Time frame: 1 day
At the moment of placing the implant, clinical variables will be evaluated: depth of probing (distance from the peri-implant margin to the most depth of the peri-implant sulcus). This will be the basal measure of the implant stability and peri-implant tissue levels. Investigators will calculate the difference between the basal measure and the future measurements.
Time frame: 8 weeks
After the implantation, we´ll load the temporary 8 weeks after the implantation. Investigators will evaluate the bone level stability at 6 weeks in both groups, through a dental X-ray radiography. The bone stability will be measured as a difference between de basal bone level and the actual one in mm.
Time frame: 8 weeks
After the implantation, we´ll load the definitive prostheses in 8 weeks. Investigators will evaluate the peri-implant tissue stability by measuring the probing depth or just in case, the recession of the gingival margin. The stability will be given by the differences between both measures, basal and actual in mm.
Time frame: 8 weeks
After the implantation, we´ll load the temporary prostheses in 8 weeks. Investigators will evaluate the peri-implant tissue stability by measuring the ISQ through RFA. The stability will be given by the differences between both measures, basal and actual.
Time frame: 6 months
After 6 months of loading of final ceramic restoration, investigators will evaluate the differences of clinical (mm of probing depth) aspects.
Time frame: 6 months
After 6 months of loading of final ceramic restoration, investigators will evaluate the differences of ISQ implant stability aspects.
ISQ, or Implant Stability Quotient, is a scale from 1 to 99 and is a measure of the stability of an implant. The ISQ scale has a non-linear correlation to micro mobility. High stability means >70 ISQ, between 60-69 is medium stability and < 60 ISQ is considered as low stability.
Time frame: 6 months
After 6 months of loading of final ceramic restoration, investigators will evaluate the differences of radiological aspects (bone implant level in mm calculated from the neck to the actual bone level), comparing on the basal and final values.
Time frame: 24 months
After 24 months of loading of final ceramic restoration, investigators will evaluate the bone level stability at 24 months in both groups, through a dental X-ray radiography. The bone stability will be measured as a difference between de basal bone level and the actual one in mm.
Time frame: 24 months
After 24 months of loading of final ceramic restoration, investigators will evaluate the peri-implant tissue stability by measuring the ISQ through Resonance Frequency Analysis (RFA). ISQ, or Implant Stability Quotient, is a scale from 1 to 99 and is a measure of the stability of an implant. The ISQ scale has a non-linear correlation to micro mobility. High stability means >70 ISQ, between 60-69 is medium stability and < 60 ISQ is considered as low stability.
The stability will be given by the differences between both measures, basal and actual.
Time frame: 24 months
After 24 months of loading of final ceramic restoration, investigators will evaluate the peri-implant tissue stability by measuring the probing depth or just in case, the recession of the gingival margin. The stability will be given by the differences between both measures, basal and actual in mm.
University of Santiago de Compostela
Other
Behavior of the Peri-implant Tissues on the Multiposition Abutment Straight Aesthetic Slim Anti-rotational Galimplant
Acronym: (PSG)
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04870658
Dental Implant Failed, Dental Prosthesis Failure
Alicante, Spain
View Trial DetailsNCT03720236
Dental Implant Failed, Dental Prosthesis Failure
Santiago de Compostela, A Coruña, Spain
View Trial DetailsNCT05024760
Dental Implant Failed, Implant Infection
Tacoma, Washington, United States
View Trial DetailsNCT03528330
Alveolar Bone Loss, Bone Diseases
Valencia, Spain
View Trial Details