Université de Montréal
Montreal, Quebec, H3C 3J7, Canada
NCT Number: NCT03862482
Brånemark System® dental implant osseointegration was introduced in 1965 as a novel approach to the replacement of missing teeth. Although this implant's machined, screw-shaped surface had excellent, well-documented, short- and long-term clinical success (Adell, R. 1987; Albrektsson, T., et al., 1981; Albrektsson, T., et al., 1986; Brånemark, P-I. , 1983; Brånemark P-I. 1987), newer implant designs were introduced that could enhance fusion of the implant to jaw bones, and better resist functional forces. One such implant, Screw-Vent®, has a fixture macro structure very similar to that of the Brånemark® implant. However, its fixture surface was acid etched (1-3µm) which could enhance osseointegration, and it has a longer, narrower machined internal-hex, friction-fit collar that could better resist functional forces.These characteristics should lead to less bone loss (Niznick, G. A., 1989). However, one clinical study (De Bruyen, et al., 1992) reported greater short-term bone loss with this implant compared to the Brånemark® implant, possibly due to its longer machined collar, and advocated long-term clinical studies. Therefore, this prospective within-subject clinical trial was undertaken in 1993 to first compare the Brånemark® implant with another implant, Swede-Vent®, a copy of the Brånemark® macro structure except for its fixture surface that was identically micro textured as that of Screw-Vent® by the same manufacturer. The effect on bone healing could then be compared between Brånemark®'s machined and Swede-Vent®'s micro textured fixture surfaces in the short- and long-terms. Since Screw-Vent®'s fixture surface was identically micro textured as that of Swede-Vent®, the investigators could then evaluate and compare the effects on bone healing of Screw-Vent®'s longer, narrower, internal-connection machined collar to the identical shorter, wider, external-connection machined collars of the Swede-Vent® and Brånemark® implants. All three two-part, platform-matched, parallel-wall implants were made of commercially pure titanium, had a very similar fixture macro design, were approved by the Food and Drug Administration (USA) and Health and Welfare Canada, and were commercially available in North America. Brånemark® and Screw-Vent® implants are still available, but the Swede-Vent® implant is not.
Looking for future studies?
Notify Me48 year–82 year
All sexes
Interventional
Not applicable
Montreal, Quebec, H3C 3J7, Canada
Therefore, between 1993 and 1996, 58 of 60 eligible participants had been recruited into a prospective, randomized clinical trial. This trial had been peer reviewed, had received ethical approval, and had taken place at the Université de Montréal's Faculty of Dental Medicine and its affiliated hospital dental department. Follow-up documentation occurred at one year, two years, and 15 to 20 years following prostheses attachment (ClinicalTrials Identification Number NCT01641198), and the results were published (Camarda, et al., 2018). The present study reports on data collected at the 25-year (24.6 ± 0.19 years, mean ± SE) follow-up (ClinicalTrials Identification Number NCT03862482), focusing specifically on the evaluation and comparison of the effects on peri-implant healing and functional osseointegration of the two different machined collar designs. That is to say, the identical shorter, wider, external-connection Brånemark® and Swede-Vent® collars versus the longer, narrower, internal-connection Screw-Vent® collar. Twenty-two of the original participants (41.5%, age 71.1 ± 1.2 years, 11 women, 110 implants) were enrolled into this study. All study procedures were performed in accordance with the Helsinki Declaration and its later amendments, and all participants signed informed consent documents prior to inclusion into this study.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Brånemark® implant placed at sites 2 (left medial) and 5 (right distal), Swede-Vent® implant placed at sites 1 (left distal) and 4 (right medial), Screw-Vent® implant placed at site 3 (para symphysis)
Brånemark® implant placed at site 3 (para symphysis), Swede-Vent® implant placed at sites 2 (left medial) and 5 (right distal), Screw-Vent® implant placed at sites 1 (left distal) and 4 (right medial)
Brånemark® implant placed at sites 1 (left distal) and 4 (right medial), Swede-Vent® implant placed at site 3 (para symphysis), Screw-Vent® implant placed at sites 2 (left medial) and 5 (right distal)
Time frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Distance between first bone-to-implant contact point (fBIC) and microgap (MG) at the crest was measured (mm) at mesial and distal sides of each implant/abutment complex on conventional peri-apical radiographs using a standardized equipment and measurement protocol (Camarda, et al., 2018) after 25 years of function. Values fBIC-MG (Mean ± SE) ("-" for bone loss) were calculated, recorded and compared between all B and all SW, between all B and all SC and between all SW and all SC dental implant units in all three Configurations
Time frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Mobility was measured by applying manual pressure on the handles of two instruments, each placed on opposite sides of the prostheses and abutments, and was recorded as 0 (no mobility or looseness) or 1 (mobility or looseness). Values (Mean ± SE) were calculated, recorded and compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
Time frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Height of the keratinized tissue was measured (mm) using a ColorVue UNC12 Hu-Friedy probe on the buccal and lingual implant/abutment surfaces. Values (Mean ± SE) were calculated, recorded and compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
Time frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Using a ColorVue UNC12 Hu-Friedy probe, probing depth was measured (mm) on the buccal, lingual, mesial and distal implant/abutment surfaces. Values (Mean ± SE) were calculated, recorded and compared between B and SW, between B and SC and between SW and SC for Configuration 1(Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent ®1, Screw-Vent® 2)
Time frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Absence (0) or presence (1) of plaque and/or gingival bleeding on probing was evaluated using the dichotomous/binary plaque index (dPI) (Galgut, P. A., 1999) and bleeding index (dBI), respectively (Galgut, P.A., 1999). Values (Mean ± SE) were compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent ®1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
Time frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Absence (0) or presence (1) of purulent exudate on probing was evaluated. Values (Mean ± SE) were recorded, and compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
Time frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
Conventional peri-apical radiology and phosphor-plate digital technology (Digora System™, Digora OptimeTM, Sporedex Dental Co., Tuusula, Finland) were used with the standardized equipment to take peri-apical radiographs on 95 implant/abutment units (Camarda, et al., 2018; Bhaskaran, et al., 2005). Following calibration, the distance between the first-bone-to-implant-contact-point and the crestal-microgap (fBIC-MG) was measured (mm) at the mesial and distal aspects of each implant/abutment unit after 25 years of function. Values (Mean ± SE) fBIC-MG were recorded for each of the two measurement systems. ICC (Intraclass Correlation Coefficient, two-way, mixed effect model) and Bland-Altman Limits of agreement (Bland & Altman, 1986) were used to evaluate the level of agreement between the two systems
Université de Montréal
Other
Prospective Randomised Clinical Trial Evaluating the Effects of Two Different Implant Collar Designs on Peri-Implant Healing and Functional Osseointegration After 25 Years of Function With Full Arch Mandibular Prostheses
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05720143
Jaw Diseases, Jaw, Edentulous
Damascus, Syria
View Trial DetailsNCT06408506
Jaw Diseases, Jaw, Edentulous
Graz, Styria, Austria
View Trial DetailsNCT04873219
Denture, Complete, Jaw Diseases
Geneva, Canton of Geneva, Switzerland
View Trial DetailsNCT05032170
Dental Impression Techniques, Jaw Diseases
Heidelberg, Baden-Wurttemberg, Germany
View Trial Details