AMCR Institute
Escondido, California, 92026, United States
NCT Number: NCT01264016
The purpose of this study is to evaluate the performance and acceptability of a new blood glucose monitoring system, which includes meter and sensor strip.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Escondido, California, 92026, United States
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Untrained subjects with diabetes performed Blood Glucose (BG) tests with subject's capillary fingerstick using the investigational Tradewind meter and investigational sensor. Study staff tested subject venous blood. All BG Results were compared to a reference laboratory glucose method. Subjects' success at performing basic tasks using only the User Guide were rated by study staff.
Time frame: 2 hours
Subjects with diabetes used an investigational blood glucose monitoring system (BGMS) with subject capillary blood. BGM results were compared to a reference lab glucose method - Yellow Springs Instrument (YSI) Analyzer. BG results were used to calculate the number of BG results within +/- 5 to 20 mg/dL (for reference BG results <75mg/dL) or +/- 5 to 20% (for reference BG results >=75mg/dL) of the reference method results.
Time frame: 2 hours
Healthcare professionals (study staff) used an investigational blood glucose monitoring system (BGMS) with subject venous blood. BGM results were compared to a reference lab glucose method - Yellow Springs Instrument (YSI) Analyzer. BG results were used to calculate the number of BG results within +/- 5 to 20 mg/dL (for reference BG results <75mg/dL) or +/- 5% to 20% (for reference BG results >=75mg/dL) of the reference method results.
Time frame: 2 hours
Subjects reviewed the instructions for use (User Guide and Quick Reference Guide) to learn to use the system. Study staff then observed and rated the subjects (1 to 4) on their success at performing five tasks. Scale: 1.Success in performing tasks correctly without assistance. 2.Successful with additional review of User Guide. 3.Successful with additional review and study staff assist similar to review of a specific function during a Customer Service call. 4.Subject did not perform task correctly and study staff intervention was required.
Ascensia Diabetes Care
Industry
Performance of the TATSU/Tradewind Blood Glucose Monitoring System
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT00837122
Cardiovascular Diseases, Diabetes
Accra, Ghana
View Trial DetailsNCT03899883
Diabetes, Diabetes Complications
Aurora, Colorado, United States
View Trial DetailsNCT00065676
Body Weight, Diabetes
Bethesda, Maryland, United States
View Trial DetailsNCT00862433
Body Weight, Diabetes
Bethesda, Maryland, United States
View Trial Details