NCT Number: NCT01264016

Performance of a New Glucose Meter System

The purpose of this study is to evaluate the performance and acceptability of a new blood glucose monitoring system, which includes meter and sensor strip.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

AMCR Institute

Escondido, California, 92026, United States

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Type 1 or 2 diabetes
  • Age 18 years or older
  • Routinely performs blood glucose self testing at home, at least once per day
  • Able to speak, read, and understand English.
  • Is willing to complete all study procedures

Exclusion criteria

  • Currently pregnant
  • Hemophilia or any other bleeding disorder
  • Taking prescription anticoagulants or has clotting problems that may prolong bleeding. Taking aspirin daily is not excluded
  • Subject employee of competitive medical device company
  • Cognitive disorder or other condition, which in the opinion of the investigator, would put the person at risk or seriously compromise the integrity of the study

Treatment and study plan

Investigational Blood Glucose Monitoring System

Device

Untrained subjects with diabetes performed Blood Glucose (BG) tests with subject's capillary fingerstick using the investigational Tradewind meter and investigational sensor. Study staff tested subject venous blood. All BG Results were compared to a reference laboratory glucose method. Subjects' success at performing basic tasks using only the User Guide were rated by study staff.

Primary outcomes

  1. Percent of Capillary Blood Glucose (BG) Results Within +/- 5 to 20mg/dL (<75 mg/dL) or Within +/- 5% to 20% (>=75 mg/dL) of Laboratory Glucose Method

    Time frame: 2 hours

    Subjects with diabetes used an investigational blood glucose monitoring system (BGMS) with subject capillary blood. BGM results were compared to a reference lab glucose method - Yellow Springs Instrument (YSI) Analyzer. BG results were used to calculate the number of BG results within +/- 5 to 20 mg/dL (for reference BG results <75mg/dL) or +/- 5 to 20% (for reference BG results >=75mg/dL) of the reference method results.

  2. Percent of Venous Blood Glucose (BG) Results Within +/- 5 to 20 mg/dL (<75 mg/dL) or Within +/- 5% to 20% (>=75 mg/dL) of Laboratory Glucose Method

    Time frame: 2 hours

    Healthcare professionals (study staff) used an investigational blood glucose monitoring system (BGMS) with subject venous blood. BGM results were compared to a reference lab glucose method - Yellow Springs Instrument (YSI) Analyzer. BG results were used to calculate the number of BG results within +/- 5 to 20 mg/dL (for reference BG results <75mg/dL) or +/- 5% to 20% (for reference BG results >=75mg/dL) of the reference method results.

Secondary outcomes

  1. Number of Subjects Rated as<=3 Performing Basic Meter Tasks (Labeling Comprehension)

    Time frame: 2 hours

    Subjects reviewed the instructions for use (User Guide and Quick Reference Guide) to learn to use the system. Study staff then observed and rated the subjects (1 to 4) on their success at performing five tasks. Scale: 1.Success in performing tasks correctly without assistance. 2.Successful with additional review of User Guide. 3.Successful with additional review and study staff assist similar to review of a specific function during a Customer Service call. 4.Subject did not perform task correctly and study staff intervention was required.

Sponsors and collaborators

Lead sponsor

Ascensia Diabetes Care

Industry

Registry information

Official study title

Performance of the TATSU/Tradewind Blood Glucose Monitoring System

Important dates

Study start
2010
Primary completion
2010
Study completion
2010
First posted
Dec 21, 2010
Registry last updated
Feb 29, 2016

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.