Skip to main content
OpenTrials
Completed

NCT Number: NCT03043404

Performance and Safety of the Lotus™ Valve With a FLEXible Delivery System

To confirm the acute performance and safety of the Lotus™ Valve Flex System for transcatheter aortic valve replacement (TAVR) in symptomatic patients with severe calcific aortic stenosis who are considered high risk for surgical valve replacement.

Completed

Looking for future studies?

Notify Me

Key information

Age range

70 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Prince Charles Hospital, Chermside, Queensland, Australia

Loading trial locations.

About this study

This clinical study is a prospective, single-arm study designed to confirm that the acute performance and safety of the Lotus Valve Flex System for TAVR are consistent with the results of the Lotus Valve System in the REPRISE II study, when delivered and deployed in symptomatic subjects who have severe calcific aortic valve stenosis and who are at high risk for surgical aortic valve replacement (SAVR).

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • 1. Subject is ≥70 years of age
  • 2. Subject has documented calcific native aortic valve stenosis with an initial aortic valve area (AVA) of <1.0 cm2 (or AVA index of <0.6 cm2/m2) and either a mean pressure gradient >40 mm Hg or a jet velocity >4 m/s, as measured by echocardiography
  • 3. Subject has a documented aortic annulus size between ≥20 and ≤27 mm based on pre-procedure diagnostic imaging
  • 4. Symptomatic aortic valve stenosis with NYHA Functional Class ≥ II
  • 5. Subject is considered high risk for surgical valve replacement based on at least one of the following:
  • Society of Thoracic Surgeons (STS) score ≥8%, AND/OR
  • Agreement by the heart team (which must include an in-person evaluation by an experienced cardiac surgeon) that subject is at high operative risk of serious morbidity or mortality with surgical valve replacement
  • 6. Heart team (which must include an experienced cardiac surgeon) assessment that the subject is likely to benefit from valve replacement.
  • 7. Subject (or legal representative) understands the study requirements and the treatment procedures, and provides written informed consent.
  • 8. Subject, family member, and/or legal representative agree(s) and subject is capable of returning to the study hospital for all required scheduled follow up visits.

Exclusion criteria

  • Subject has a congenital unicuspid or bicuspid aortic valve.
  • Subject with an acute myocardial infarction within 30 days of the index procedure (defined as Q-wave MI or non-Q-wave MI with total CK elevation ≥ twice normal in the presence of CK-MB elevation and/or troponin elevation).
  • Subject has had a cerebrovascular accident or transient ischemic attack within the past 6 months, or has any permanent neurologic defect prior to study enrollment.
  • Subject is on dialysis or has serum creatinine level >3.0 mg/dL or 265 µmol/L.
  • Subject has a pre-existing prosthetic heart valve (aortic or mitral) or a prosthetic ring in any position.
  • Subject has ≥3+ mitral regurgitation, ≥3+ aortic regurgitation or ≥3+ tricuspid regurgitation (i.e., subject cannot have more than moderate mitral, aortic or tricuspid regurgitation).
  • Subject has a need for emergency surgery for any reason.
  • Subject has a history of endocarditis within 12 months of index procedure or evidence of an active systemic infection or sepsis.
  • Subject has echocardiographic evidence of intra-cardiac mass, thrombus or vegetation.
  • Subject has Hgb <9 g/dL, platelet count <50,000 cells/mm3 or >700,000 cells/mm3, or white blood cell count <1,000 cells/mm3.
  • Subject requires chronic anticoagulation therapy (warfarin) and cannot tolerate concomitant therapy with either aspirin or clopidogrel.

Note: Subjects who require chronic anticoagulation must be able to be treated additionally with either aspirin or clopidogrel. An alternative P2Y12 inhibitor may be prescribed if subject is allergic to or intolerant of clopidogrel.

  • Subject has active peptic ulcer disease or gastrointestinal bleed within the past 3 months, other bleeding diathesis or coagulopathy or will refuse transfusions.
  • Subject has known hypersensitivity to contrast agents that cannot be adequately pre-medicated, or has known hypersensitivity to aspirin, all thienopyridines, heparin, nickel, tantalum, titanium, or polyurethanes.
  • Subject has a life expectancy of less than 12 months due to non-cardiac, co-morbid conditions based on the assessment of the investigator at the time of enrollment.
  • Subject has hypertrophic obstructive cardiomyopathy.
  • Subject has any therapeutic invasive cardiac procedure (including balloon aortic valvuloplasty) within 30 days prior to the index procedure (except for pacemaker implantation which is allowed).
  • Subject has untreated coronary artery disease, which in the opinion of the treating physician is clinically significant and requires revascularization.
  • Subject has documented left ventricular ejection fraction <30%.
  • Subject is in cardiogenic shock or has hemodynamic instability requiring inotropic support or mechanical support devices.
  • Subject has severe peripheral vascular disease (including aneurysm defined as maximal luminal diameter >5 cm or with documented presence of thrombus, marked tortuosity, narrowing of the abdominal aorta, severe unfolding of the thoracic aorta or thick [>5 mm], protruding or ulcerated atheroma in the aortic arch) or symptomatic carotid or vertebral disease.
  • Femoral artery lumen of <6.0 mm for subjects requiring 23 mm valve size or <6.5 mm for subjects requiring 27 mm valve size, or severe iliofemoral tortuosity or calcification that would prevent safe placement of the introducer sheath.
  • Current problems with substance abuse (e.g., alcohol, etc.).
  • Subject is participating in another investigational drug or device study that has not reached its primary endpoint.
  • Subject has untreated conduction system disorder (e.g., Type II second degree atrioventricular block) that in the opinion of the treating physician is clinically significant and requires a pacemaker implantation.

Treatment and study plan

Transcatheter Aortic Valve Replacement

Device

TAVR with Lotus Valve Flex System

Primary outcomes

  1. Technical success

    Time frame: immediately post-procedure

    defined as successful vascular access, delivery and deployment of the Lotus Valve and successful retrieval of the delivery system; and correct positioning of a single Lotus Valve in the proper anatomical location; reported as percent of subjects.

Secondary outcomes

  1. Mean aortic valve pressure gradient and effective orifice area

    Time frame: at discharge or 7 days post-procedure (whichever comes first)

    as measured by echocardiography and assessed by an independent core laboratory

  2. Device performance

    Time frame: at discharge or 7 days post-procedure (whichever comes first)

    defined as successful repositioning of the Lotus Valve if repositioning is attempted; and successful retrieval of the Lotus Valve if retrieval is attempted; and grade of paravalvular aortic regurgitation, as measured by echocardiography and assessed by an independent core laboratory

Other outcomes

  1. Mortality: all-cause, cardiovascular, and non-cardiovascular

    Time frame: at discharge or 7 days post-procedure (whichever comes first), 30 days, 6 months, and 1, 2, 3, 4, and 5 years post procedure

  2. Stroke: disabling and non-disabling

    Time frame: at discharge or 7 days post-procedure (whichever comes first), 30 days, 6 months, and 1, 2, 3, 4, and 5 years post procedure

  3. Composite of all-cause mortality and disabling stroke

    Time frame: at discharge or 7 days post-procedure (whichever comes first), 30 days, 6 months, and 1, 2, 3, 4, and 5 years post procedure

  4. Bleeding: life-threatening (or disabling) and major

    Time frame: at discharge or 7 days post-procedure (whichever comes first), 30 days, 6 months, and 1, 2, 3, 4, and 5 years post procedure

  5. Myocardial infarction (MI)

    Time frame: periprocedural (≤72 hours post index procedure) and spontaneous (>72 hours post index procedure)

  6. Acute kidney injury: based on the AKIN System Stage 3 (including renal replacement therapy) or Stage 2

    Time frame: ≤7 days post index procedure

  7. Major vascular complication

    Time frame: at discharge or 7 days post-procedure (whichever comes first), 30 days, 6 months, and 1, 2, 3, 4, and 5 years post procedure

  8. Repeat procedure for valve-related dysfunction (surgical or interventional therapy)

    Time frame: at discharge or 7 days post-procedure (whichever comes first), 30 days, 6 months, and 1, 2, 3, 4, and 5 years post procedure

  9. Hospitalization for valve-related symptoms or worsening congestive heart failure (NYHA class III or IV)

    Time frame: at discharge or 7 days post-procedure (whichever comes first), 30 days, 6 months, and 1, 2, 3, 4, and 5 years post procedure

  10. New permanent pacemaker implantation resulting from new or worsened conduction disturbances (including new left bundle branch block [LBBB] and third degree atrioventricular block)

    Time frame: at discharge or 7 days post-procedure (whichever comes first), 30 days, 6 months, and 1, 2, 3, 4, and 5 years post procedure

  11. New onset of atrial fibrillation or atrial flutter

    Time frame: at discharge or 7 days post-procedure (whichever comes first), 30 days, 6 months, and 1, 2, 3, 4, and 5 years post procedure

  12. Coronary obstruction

    Time frame: ≤7 days post procedure

  13. Ventricular septal perforation, reported as percent of subjects

    Time frame: ≤7 days post procedure

  14. Mitral apparatus damage, reported as percent of subjects

    Time frame: ≤7 days post procedure

  15. Cardiac tamponade, reported as percent of subjects

    Time frame: ≤7 days post procedure

  16. Prosthetic aortic valve malposition, including valve migration, valve embolization, ectopic valve deployment, or transcatheter aortic valve (TAV)-in-TAV deployment

    Time frame: at discharge or 7 days post-procedure (whichever comes first), 30 days, 6 months, and 1, 2, 3, 4, and 5 years post procedure

  17. Prosthetic aortic valve thrombosis

    Time frame: at discharge or 7 days post-procedure (whichever comes first), 30 days, 6 months, and 1, 2, 3, 4, and 5 years post procedure

  18. Prosthetic aortic valve endocarditis

    Time frame: at discharge or 7 days post-procedure (whichever comes first), 30 days, 6 months, and 1, 2, 3, 4, and 5 years post procedure

  19. Prosthetic aortic valve performance

    Time frame: at discharge or 7 days post-procedure (whichever comes first), 30 days, 6 months, and 1, 2, 3, 4, and 5 years post procedure

    as measured by transthoracic echocardiography (TTE) and assessed by an independent core laboratory, including effective orifice area, mean and peak aortic gradients, peak aortic velocity, and grade of aortic regurgitation

  20. Functional status

    Time frame: at discharge or 7 days post-procedure (whichever comes first), 30 days, 6 months, and 1, 2, 3, 4, and 5 years post procedure

    as evaluated by the New York Heart Association (NYHA) classification

  21. Neurological status

    Time frame: at discharge and 1 year

    as determined by the National Institutes of Health Stroke Scale (NIHSS)

  22. Neurological status

    Time frame: at discharge or 7 days post-procedure (whichever comes first), 30 days, 6 months, and 1, 2, 3, 4, and 5 years post procedure

    as determined by the Modified Rankin Scale (mRS)

Sponsors and collaborators

Lead sponsor

Boston Scientific Corporation

Industry

Registry information

Official study title

REPRISE II FLEX: Repositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of LotuS™ ValvE With a FLEXible Delivery System - Confirmation of Performance and Safety

Important dates

Study start
2013
Primary completion
2013
Study completion
2018
First posted
Feb 6, 2017
Registry last updated
Jul 5, 2019

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.