CS1 & heart monitor
DeviceDaily activities while wearing the investigational device as well as the control device
NCT Number: NCT03477734
A Prospective, Open, Multi-Center, Controlled Study to Evaluate the Safety, Performance and Efficacy of the CardiacSense1 for Detection of Atrial Fibrillation.
The clinical study is intended to establish the efficacy and safety of the CardiacSense1 wearable device intended to monitor and detect heart arrhythmia, specifically atrial fibrillation (A-Fib) based on a comparison to a control device, which is an off-the-shelf cleared Holter ECG device
Looking for future studies?
Notify Me18 year–85 year
All sexes
Interventional
Not applicable
Rambam Medical Center, Haifa, Israel
The clinical study is intended to establish the efficacy and safety of the CardiacSense1 wearable device intended to monitor and detect heart arrhythmia, specifically atrial fibrillation (A-Fib). Study design as as follows:
100 subjects, 50 (at least 30% of each gender) with A-fib and 50 without (at least 30% of each gender).
All subjects will be measured during at least 24 hours. Primary endpoint - A-Fib detection Control: Holter device will be the reference
For PPG analysis, each one hour will be considered as an event:
If A-Fib is present for more than accumulated 5 minutes in that specific hour then it shall be considered an "A-Fib hour" If A-fib was present for less than accumulated 5 minutes then it shall be considered a "Non-A-Fib hour".
For ECG analysis, each measurement of between 1-3 minutes will be considered an event.
If A-Fib is present at that specific measurement, then it shall be considered an "A-Fib event" If A-fib was not present at that specific measurement, then it shall be considered a "Non-A-Fib hour".
Sensitivity (true positive) is defined as the percentage of Holter defined "A-fib hours"/"A-Fib event" found by PPG/ECG.
The asked sensitivity is 90%. Specificity (true negative) is defined as the percentage of Holter defined "Non-A-fib hours"/"A-Fib event" found by PPG/ECG. The required specificity is 90%.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Daily activities while wearing the investigational device as well as the control device
Time frame: 24 to 48 hours
Comparison of the number of atrial fibrillation sessions detected by reference comparing to PPG and ECG sensors in CardiacSense device.
Time frame: 24 to 48 hours
Incidence and severity of device related Adverse Events
Time frame: 24 to 48 hours
Ease of use of the CardiacSense1 device based on user questionnaire
CardiacSense Ltd.
Industry
A Prospective, Open, Multi-Center, Controlled Study to Evaluate the Safety, Performance and Efficacy of the CardiacSense1 for Detection of Atrial Fibrillation
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05456204
Arrhythmias, Cardiac, Atrial Fibrillation
Moscow, Russia
View Trial DetailsNCT04293198
Ablation, Arrhythmias, Cardiac
Baltimore, Maryland, United States
View Trial DetailsNCT02949180
Arrhythmia Atrial, Arrhythmias, Cardiac
Greifswald, Germany
View Trial DetailsNCT06165510
Arrhythmias, Cardiac, Atrial Arrhythmia
London, United Kingdom
View Trial Details