Mohamed Sharaf
Banī Suwayf, 11625, Egypt
NCT Number: NCT05079048
comparing retention and patient satisfaction of implant-supported mandibular overdentures retained by conventional nylon clip and metal housings for ball attachments versus PEEK clip and housings
Looking for future studies?
Notify MeAll sexes
Interventional
Not applicable
Banī Suwayf, 11625, Egypt
Background. Many patients suffer from lack of retention of conventional mandibular overdentures due to loss of clip retention over time. Computer-aided design-computer-aided manufacturing (CAD-CAM) milled polyetheretherketone PEEK materials may be used for construction of retentive housing and clip for improving retention of implant-supported overdentures.
Objective . To compare retention and patient satisfaction of implant-supported mandibular overdentures retained by conventional nylon clip and metal housings for ball attachments versus PEEK clip and housings.
Methods: Twenty-two participants were divided into 2 equal groups (n=11). The conventional group received implant-supported mandibular overdentures retained by metal housings and nylon retentive elements, while the PEEK group received implant-supported mandibular overdenture retained by PEEK retentive element and housings.The PEEK retentive elements were made by using computer-aided design and computer-aided manufacturing (CAD-CAM).Evaluation included measuring the retention by applying a gradual pulling up force by forcemeter and patient satisfaction with a 7-point visual analog scale (VAS) at overdenture insertion , 3,6, and 12 months subsequently by research interviewer.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
received implant-supported mandibular overdenture retained by PEEK retentive element and housings
Other names: PEEK housing and clip
Time frame: 3 months to six months
measuring retention force of retentive elements using The force-meter machine (Eagle: ELT 3000) . Gradual pulling up force was applied. The record appeared at the screen of the force meter was recorded as it's single-blind measurements.
Time frame: 3 months to six months
measuring patient satisfaction using Visual analog scale (VAS) was used for the evaluation of overall patient satisfaction. All questionnaires were taken by the same research interviewer (assisted interviewer) as he was blind about the type of prosthesis (double-blind) as the research interviewer is from another department
Cairo University
Other
Novel PEEK Retentive Elements Versus Conventional Retentive Elements in Mandibular Overdentures: A Randomized Controlled Trial
Acronym: PEEK
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06818890
Dental Implant, Partially Edentulous Mandible
Mangaluru, Karnataka, India
View Trial DetailsNCT05016401
Mouth Diseases, Partially Edentulous Mandible
Bandol, France
View Trial DetailsNCT03814655
Partially Edentulous Mandible, Partially Edentulous Maxilla
Bucharest, Romania
View Trial DetailsNCT01142297
Diabetes Mellitus, Diabetes Mellitus, Type 2
San Antonio, Texas, United States
View Trial Details