Pediatric Resuscitation With Feedback CPR Devices

The aim of this study was to compare the TrueCPR feedback device (with metronome) to standard basic life support (BLS) in terms of the quality of single rescuer pediatric resuscitation. Therefore, our hypothesis was that there would be no difference between both CPR methods in terms of chest compression quality parameters.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–65 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

International Institute of Rescue Research and Education

Warsaw, Masovia, 03-122, Poland

About this study

Cardiac arrest is a leading cause of death worldwide. High-quality chest compressions are of paramount importance for survival and good neurological outcome. Unfortunately, even health professionals have difficulty performing effective CPR. Chest compression (CC) is often too shallow, compression ratio is inadequate, and hands-off time is too long. CPR feedback devices might be an option for rescuers to in order to increase CC efficiency.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • give voluntary consent to participate in the study
  • medical profession (paramedics, nurses, physicians) or medical students (nurses, paramedics, physicians)

Exclusion criteria

  • not meet the above criteria
  • wrist or low back diseases

Treatment and study plan

The TrueCPR feedback device

Device

feedback devices

Standard BLS

Device

Standard basic life support = chest compressions without any feedback device (manual resuscitation)

Primary outcomes

  1. Effective compressions compression with correct depth (40-50mm), correct hand position and complete decompressions

    Time frame: 1 month

    effective compressions was defined as compression with correct depth (40-50mm), correct hand position and complete decompressions

Secondary outcomes

  1. effective compressions ratio effective compressions [%] multiplied by flow time [%]

    Time frame: 1 month

    effective compressions ratio was defined as effective compressions [%] multiplied by flow time [%]

  2. Flow time sum of all periods during which chest compressions were performed.

    Time frame: 1 month

    flow time was defined as the sum of all periods during which chest compressions were performed.

  3. absolute hands-off time sum of all periods without chest compressions or ventilation

    Time frame: 1 month

    absolute hands-off time (HOT) was defined as the sum of all periods without chest compressions or ventilation

  4. Compression depth compression in correct depth (40-50mm) measured by the software is connected to the manikin and computer

    Time frame: 1 month

    compression in correct depth (40-50mm) measured by the software is connected to the manikin and computer

Sponsors and collaborators

Lead sponsor

International Institute of Rescue Research and Education

Other

Registry information

Official study title

Is Chest Compressions Using the TrueCPRTM Feedback Device More Effective Than Manual Compressions During Pediatric Resuscitation? A Manikin Study

Acronym: PRFD

Important dates

Study start
2014
Primary completion
2014
Study completion
2014
First posted
Nov 4, 2014
Registry last updated
Nov 18, 2014

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.