Skip to main content
OpenTrials
Completed

NCT Number: NCT06111391

Patient Satisfaction , Prosthetic Complications and Clinical Outcomes of PEEK Composite Versus Titanium Zirconium

This study aimed to evaluate patient satisfaction (VAS) , prosthetic outcomes and clinical outcomes of polyether ether ketone (PEEK) Versus Titanium Zirconium fixed prostheses supported by six maxillary implants and opposed by distal extension removable partial denture.

Completed

Looking for future studies?

Notify Me

Key information

Age range

58 year–68 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Mansoura university

Al Mansurah, 35516, Egypt

About this study

thirty patients were selected for this study from a previous study who have already received previous implants in the maxillary arch. The patients were divided into two groups: Group1 received maxillary titanium zirconium full arch fixed prosthesis and mandibular distal extension partial denture, Group 2 received maxillary PEEK composite full arch fixed prosthesis and mandibular distal extension partial denture Patient satisfaction was evaluated using visual analogue scale (VAS) after one year months , Prosthetic complications were measured on the patient and implant levels after one year

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

Normal jaw relation Good oral hygiene Patient with class I or class II inter-rach space in order to have sufficient restoration space to construct FP3 prosthesis.

Exclusion criteria

Patients with TMJ disorder and heavy smokers for more than 10 cigarettes per day.

Uncooperative patient. Unfavorable occlusion. Limited restoration space (less than 12 mm).

Treatment and study plan

Osstell® device (Integration Diagnostics Ltd.).

Device

After trans-mucosal abutments were removed and the smart pegs were attached to the fixtures, resonance frequency analysis was done to assess implant stability.The implant stability quotient (ISQ) was used to quantify stability via the Osstell® device (Integration Diagnostics Ltd.).

Primary outcomes

  1. implant stability

    Time frame: 12 months

    After transmucosal abutments were removed and the smart pegs were attached to the fixtures, resonance frequency analysis was done to assess implant stability.The implant stability quotient (ISQ) was used to quantify stability via the Osstell® device (Integration Diagnostics Ltd.).

Sponsors and collaborators

Lead sponsor

Mansoura University

Other

Registry information

Official study title

Patient Satisfaction , Prosthetic Complication and Clinical Outcomes of PEEK Composite Versus Titanium Zirconium Maxillary Fixed Full Arch Prosthetic Opposing Mandibular Distal Extension Partial Denture

Important dates

Study start
2022
Primary completion
2023
Study completion
2023
First posted
Nov 1, 2023
Registry last updated
Nov 1, 2023

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.