Boca Raton Regional Hospital
Boca Raton, Florida, 33486, United States
NCT Number: NCT03456427
Patient-assisted compression (PAC) allows the patient to participate in controlling the amount of compression force during mammography and is a personalized approach that has demonstrated successful reduction in discomfort experienced during mammography. General Electric Healthcare's Senographe Pristina, an innovative mammography platform that provides both two-dimensional (2D) and three-dimensional (3D) imaging capabilities, offers both standard and patient-assisted compression modes. This study will evaluate image quality and clinical workflow as it relates to use of PAC with the Senographe Pristina 3D.
Looking for future studies?
Notify Me40 year and older
Female
Interventional
Not applicable
Boca Raton, Florida, 33486, United States
The study population will consist of adult asymptomatic women presenting for screening 2D mammography. One breast of each subject will be identified as the "breast of interest," which will undergo study-specific 3D imaging consisting of two-view (craniocaudal and mediolateral oblique) PA compression and image acquisition, followed by two-view technologist-controlled (TC) compression and image acquisition. The breast of interest will be randomly assigned to either the first breast imaged during the exam or the second breast imaged. TC compression and imaging, and procedures performed on the subject's other breast will be conducted per standard of care.
Following image acquisition, 3D image quality evaluation will be conducted by Mammography Quality Standards Act-qualified readers. Prior to the reading session, images will be de-identified and the following information will be removed from the DICOM header to blind readers to the compression mode used during acquisition: time stamp, compression force, and breast thickness. The image sets will also be randomized for presentation during the image attribute reviews. Two (2) readers will evaluate each PAC and TC compression image set collected from each subject's breast of interest and assess the acceptability of image attributes, as defined in the Guidance for Industry and FDA Staff - Class II Special Controls Guidance Document: Full-Field Digital Mammography System (2012). A third reader will provide adjudication, if there is disagreement for a given image set's overall clinical image quality.
Workflow data, including the incidence of technologist intervention during acquisition and need for repeat image acquisition, will also be collected.
The proportion of PAC image sets that are of equal or higher acceptability than TC image sets will be calculated. A 95% confidence interval will be calculated using asymptotic method with continuity correction. The proportion of image sets indicated for repeated image acquisition when using PA mode or TC mode will be summarized. Other endpoint data will be summarized using descriptive statistics. No statistical hypothesis is being tested in this study.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The technologist will properly position the breast and apply minimum compression. The subject will be instructed to apply compression as the technologist ensures the breast tissue is in appropriate position and tautness. The technologist will then guide the subject to achieve appropriate compression level, sufficient but not excessive, and the image will be acquired. This will be done for both standard views Craniocaudal (CC) & Mediolateral Oblique (MLO).
TC compression will be conducted per standard of care practices at the site.
Time frame: 1 Day
The primary objective is to compare the percentage of acceptable overall image quality in unilateral two-view (CC and MLO) breast images acquired using Patient-Assisted Compression and Technologist Compression modes.
Time frame: 1 Day
To evaluate the need for repeat image acquisition when using Patient-Assisted Compression and Technologist Compression modes.
Time frame: 1 Day
To evaluate the percentage of acceptable mammographic attributes for unilateral two-view breast images acquired using Patient-Assisted Compression and Technologist Compression modes.
GE Healthcare
Industry
Acronym: 3D PAC
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06068257
Breast Cancer, Breast Diseases
Orlando, Florida, United States
View Trial DetailsNCT05754658
Breast Cancer, Breast Diseases
Philadelphia, Pennsylvania, United States
View Trial DetailsNCT07040514
Breast Cancer, Breast Diseases
Lebanon, New Hampshire, United States
View Trial DetailsNCT06604858
Breast Cancer, Breast Diseases
A Coruña, Spain
View Trial Details