Continuous Glucose Monitor
DeviceCGM device for measurement of interstitial glucose on a 24/7 continuous cycle.
Other names: Dexcom G4 professional version Continuous Glucose Monitor
NCT Number: NCT02074384
International Diabetes Center (IDC) proposes a preference and usability study of glucose data acquisition and reporting, evaluating streamlined standardized cloud-based glucose reporting including work flow as well as patient and clinician preference at Type 1 Diabetes (T1D) Exchange sites to enhance standard Ambulatory Glucose Profile (AGP) reporting. This phase 2 project assesses the efficacy of standardized glucose data report generation and preferred report presentation format; both are necessary to increase use of continuous glucose monitoring (CGM) data to improve care processes and outcomes for Type 1 diabetes.
Looking for future studies?
Notify Me7 year and older
All sexes
Interventional
Not applicable
Eda Cengiz, New Haven, Connecticut, United States
Patient participation in diabetes treatment has relied upon episodic self-monitoring of blood glucose (SMBG). SMBG assists patients and clinicians with adjustments of insulin, identification of hypoglycemia, nutritional intake and activity in order to optimize diabetes control. SMBG however is subject to bias dependent upon the testing frequency and timing. In contrast, continuous glucose monitoring (CGM) systems capture continuous 24-hour glucose data uninterrupted and unbiased. It provides valuable information about daily/nightly alterations in glucose patterns. Unfortunately SMBG, CGM and insulin pump devices have proprietary software with unique data standards, acquisition methods, reports, and graphic displays. These differences make evaluation and comparison of SMBG or CGM data difficult for clinicians and patients. IDC created an Ambulatory Glucose Profile (AGP) report to reduce challenges of device specific reports through a standardized report which is produced from any device with streamlined graphic displays of glucose trends.
The phase 1 project (2012), gathered expert stakeholders (clinical, research, industry, patients) who validated data standards and recommended changes to the CGM-AGP reports. These changes are now integrated into a secure cloud-based infrastructure for AGP reporting.
Phase 2 of this project is a usability and preference study of glucose reporting systems. It will include an in depth study of 6 T1D Ex clinical sites. The T1D Exchange Clinic Network was formed to support the development of a large registry of adults and children with type 1 diabetes for the purpose of conducting multiple studies proposed by T1D Exchange investigators, and other researchers, patients, and companies.
The 6 sites will be selected for an in-depth study utilizing middleware data collection services (Diasend or SweetSpot) to facilitate efficient collection of data from diverse devices. These middleware solutions integrate with the captūrAGP system to automatically produce an AGP report. These sites will test the feasibility of AGP cloud reporting while collecting patient and clinician opinions on report preference. All 6 sites participating in phase 2 will collect patient and clinician preference measures. Two study sites will undergo time in motion (TIM) measurement and workflow mapping of current process. This TIM sub-study includes workflow mapping of current and cloud-based processes utilizing Toyota Lean (Kaizen) methodology. Sites 3 - 6 will receive enhanced designs through the adaptive trial method with learnings applied from sites 1 and 2.
A key deliverable of this study is patient and clinician insight into their utilization of CGM reporting technologies. Recognizing that adoption of technology is often stymied by time constraints, report reliability and ease of interpretation, these variables will be examined. The goal of phase 2 is to analyze the viability of standard reporting and to evaluate preference (patient and clinicians) for and perceived value of different types of glucose pattern reports (AGP vs. device) including clinical practice time saved.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
CGM device for measurement of interstitial glucose on a 24/7 continuous cycle.
Other names: Dexcom G4 professional version Continuous Glucose Monitor
Participants will use their own SMBG device.
Survey of clinicians after study visits
Time frame: At the end of the two week SMBG or CGM period
Patients will use either SMBG or CGM for a two week period following their screening visit. At the end of the two week period they will return to the study site to download their device and have an AGP report printed. They will then complete a preference and utility survey.
HealthPartners Institute
Other
Understanding Patient and Provider Glucose Reporting Preferences in Type 1 Diabetes: Cloud Based Ambulatory Glucose Profile (AGP)
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05488119
Autoimmune Diseases, Diabetes Mellitus
Stanford, California, United States
View Trial DetailsNCT07696780
Autoimmune Diseases, Diabetes Mellitus
Bern, Canton of Bern, Switzerland
View Trial DetailsNCT05610111
Autoimmune Diseases, Diabetes Mellitus
Charlottesville, Virginia, United States
View Trial DetailsNCT06308549
Autoimmune Diseases, Diabetes Distress
Bad Mergentheim, Baden-Wurttemberg, Germany
View Trial Details