This study aimed to assess correlations between muscle tone, stabilization of the trunk and the upper extremity, and parameters of hand/wrist motor coordination in post-stroke patients and neurologically healthy subjects with lower back pain.
Looking for future studies?
Notify Me44 year–83 year
All sexes
Interventional
Not applicable
Warsaw, Masovian District, 04-141, Poland
A Luna electromyography (EMG) (EGZOTech) was used to measure muscle tension, and a manual electronic dynamometer (EH 101) was used for grip strength measurement (error of measurement, 0.5 kg/lb). A Hand Tutor device (composed of a safe and comfortable glove equipped with position and motion sensors, and the Medi Tutor (TM) software was used to measure the range of passive and active movement, as well as the speed/frequency of movement. The Hand Tutor glove was worn on the hand of the directly affected side in stroke patients and on the dominant extremity in patients with pain syndrome. Surface electrodes (single-use 55' and '40 mm; ECG Electrodes; limited liability company and limited partnership (Sorimex), Poland were affixed to the subject's body according to the SENIAM (Surface ElectroMyoGraphy for the Non-Invasive Assessment of Muscles) procedure on the transverse abdominal, multifidus, and supraspinal muscles (on the side directly affected in stroke patients, and on the dominant side in patients with back pain syndrome). Before each exercise, the subject was instructed on how the exercise should be done.
The examination consisted of two motor tasks, carried out in two different starting positions: sitting and lying down (supine).
During the first examination, the subject sat on the therapeutic table (without back support), feet resting on the floor. The upper limb was examined in adduction of the humeral joint, with the elbow bent in the intermediate position between pronation and supination of the forearm, with free wrist and the hand.
In the supine position, the upper limb was stabilized at the subject's body (adduction in the humeral joint, elbow flexion in the intermediate position, wrist and hand free).
In each of the starting positions, after putting the glove on, the range of passive movement in the radial-carpal joint (flexion and extension) and fingers (global flexion and extension) was measured. Then the subject made active movement in the same order. Finally, the subject was asked to make moves as quickly and in as full a range as possible. Finally, the measurement of grip strength with a dynamometer was performed in both analyzed starting positions, after completing the range of motion and speed or frequency tests.
First, the range of passive movement in the radial-carpal joint (flexion and extension) and fingers (global flexion and extension) was measured in each position (sitting or supine) using the Hand Tutor Device. Then the subject made active movements in the same order. Finally, the subject was asked to make moves as quickly and in as full a range as possible. The measurement of grip strength with a dynamometer was performed in both positions (sitting or supine) after the range of motion and speed/frequency tests. The reaction of the examined multifidus, transverse abdominal, and supraspinatus muscles (tension values reported in microvolts (µV) was also assessed during each of the exercise tasks using the surface electrodes (i.e., during movement of the wrist and during movement of the fingers).
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Study Group
Inclusion criteria
Exclusion criteria
Control Group
Inclusion criteria
Exclusion criteria
The subject sat on the therapeutic table (without back support), feet resting on the floor. The upper limb was to be examined in adduction of the humeral joint, with the elbow bent in the intermediate position between pronation and supination of the forearm, with free wrist and the hand. After putting the glove on, the range of passive movement in the radial-carpal joint (flexion and extension) and fingers (global flexion and extension) was measured. Then the subject made active movement in the same order. Finally, the subject was asked to make moves as quickly and in as full a range as possible. Finally, the measurement of grip strength with a dynamometer was performed.
In the supine position, the upper limb was stabilized at the subject's body (adduction in the humeral joint, elbow flexion in the intermediate position, wrist and the hand free). After putting the glove on, the range of passive movement in the radial-carpal joint (flexion and extension) and fingers (global flexion and extension) was measured. Then the subject made active movement in the same order. Finally, the subject was asked to make moves as quickly and in as full a range as possible. Finally, the measurement of grip strength with a dynamometer was performed.
Time frame: up to 10 weeks
The Hand Tutor allows measurements of the range of passive movement (in mm).
Time frame: up to 10 weeks
Grip strength, kg (a manual electronic dynamometer (EH 101) was used for grip strength measurement (error of measurement, 0.5 kg/lb)
Time frame: up to 10 weeks
A Luna electromyography (EMG) (a rehabilitation-diagnostic robot developed by EGZOTech) was used to measure muscle tension. Surface electrodes (single-use 55' and '40 mm; ECG Electrode; limited liability company, limited partnership (Sorimex), Poland) were affixed to the subject's body according to the Surface Electromyography for the Non-Invasive Assessment of Muscles (SENIAM) procedure on the transverse abdominal, multifidus, and supraspinal muscles.
Time frame: up to 10 weeks
The Hand Tutor allows measurements of the range of active movement (in mm).
Time frame: up to 10 weeks
The Hand Tutor allows measurements of the extension deficit. The extension deficit refers to the difference between passive and active extension ROM.
Time frame: up to 10 weeks
The Hand Tutor allows measurements of the flexion deficit. The flexion deficit refers to the difference between passive and active flexion ROM.
Time frame: up to 10 weeks
The Hand Tutor allows measurements of the maximum range of motion (ROM).
ROM is a sum of the wrist flexion or extension angles (mm). ROM is a sum of all the finger flexion or extension angles (i.e. at the metacarpophalangeal (MCP), proximal interphalangeal (PIP), and distal interphalangeal (DIP) joints), mm.
Time frame: up to 10 weeks
The Hand Tutor allows measurements the speed or frequency (i.e., the number of cycles per second, where one cycle represents the movement from flexion to contraction).
Anna Olczak
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02425345
Arterial Occlusive Diseases, Arteriosclerosis
View Trial DetailsNCT05589402
Bone Diseases, Brain Diseases
Harlingen, Texas, United States
View Trial DetailsNCT06750692
Brain Diseases, Cardiovascular Diseases
Afyonkarahisar, Turkey (Türkiye)
View Trial DetailsNCT04992195
Alzheimer Disease, Arterial Thromboembolism
Hong Kong
View Trial Details