Skip to main content
OpenTrials
Completed

NCT Number: NCT01314313

PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - XT Intermediate and High Risk

The purpose of this trial is to determine the safety and effectiveness of the Edwards SAPIEN XT transcatheter heart valve and delivery systems which are intended for use in patients with symptomatic, calcific, severe aortic stenosis.

Completed

Looking for future studies?

Notify Me

Key information

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

St. Paul's Hospital, Providence Health Care, Vancouver, British Columbia, Canada

Loading trial locations.

About this study

The PIIA cohort is a prospective multi-center trial undergoing aortic valve replacement for severe aortic stenosis. Patients randomized to the treatment arm will receive an Edwards SAPIEN XT THV with either transfemoral, transapical or transaortic delivery access. Patients in the control arm will receive a surgical bioprosthetic heart valve via aortic valve replacement surgery.

To assure that patients with an STS score ≥ 4% have been selected.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patient has senile degenerative aortic valve stenosis with echocardiographically derived criteria: mean gradient >40 mmHg or jet velocity greater than 4.0 m/s and an initial aortic valve area (AVA) of ≤0.8 cm2 or indexed EOA < 0.5 cm2/m2 Qualifying echo must be within 60 days of the date of the procedure.
  • Patient is symptomatic from his/her aortic valve stenosis, as demonstrated by NYHA Functional Class II or greater.
  • The heart team agrees (and verified in the case review process) that valve implantation will likely benefit the patient.
  • The study patient or the study patient's legal representative has been informed of the nature of the study, agrees to its provisions and has provided written informed consent as approved by the Institutional Review Board (IRB) of the respective clinical site.
  • The study patient agrees to comply with all required post-procedure follow-up visits including annual visits through 5 years and analysis close date visits, which will be conducted as a phone follow-up.
  • Study patient agrees to undergo surgical aortic valve replacement (SAVR) - if randomized to control treatment.

Exclusion criteria

  • Evidence of an acute myocardial infarction ≤ 1 month (30 days) before the intended treatment [defined as: Q wave MI, or non-Q wave MI with total CK elevation of CK-MB ≥ twice normal in the presence of MB elevation and/or troponin level elevation (WHO definition)].
  • Aortic valve is a congenital unicuspid or congenital bicuspid valve, or is non-calcified.
  • Mixed aortic valve disease (aortic stenosis and aortic regurgitation with predominant aortic regurgitation >3+).
  • Preexisting mechanical or bioprosthetic valve in any position (except NR3).
  • Any therapeutic invasive cardiac procedure resulting in a permanent implant that is performed within 30 days of the index procedure (unless part of planned strategy for treatment of concomitant coronary artery disease). Implantation of a permanent pacemaker or ICD (S3 Cohort only) is not excluded.
  • Heart team assessment of inoperability (including examining cardiac surgeon).

Treatment and study plan

TAVR Implantation with SAPIEN XT

Device

Operable Group with SAPIEN XT

SAVR Implantation

Device

Control Group

Primary outcomes

  1. All-cause Death or Disabling Stroke to Two Years

    Time frame: 2 Years

    All-cause Death or Disabling Stroke (Edwards SAPIEN XT THV vs SAVR)

Secondary outcomes

  1. Adjusted Days Alive and Out of Hospital (DAOH) to Two Years

    Time frame: 2 years

    The number of days the patients are alive and out of the hospital.

  2. Total Aortic Regurgitation (AR) at 2 Years

    Time frame: 2 years

    Total aortic regurgitation was assessed by the core lab as "Grade 0" = None, "Grade 1+" = Trace, "Grade 2+" = Mild, "Grade 3+" = Moderate and "Grade 4+" = Severe. Total regurgitation at two year was analyzed in the valve implant population.

  3. 6MWT Change From Baseline

    Time frame: Baseline and 2 years

    Six Minute Walk Test change from baseline to 2 years

  4. NYHA Classification at 2 Years

    Time frame: 2 years

    New York Heart Association (NYHA), functional classification of heart failure based on how much a patient is limited during physical activity. The rating ranges from I - IV, with the lowest as no limitations and the highest unable to carry on any physical activity without discomfort.

  5. Effective Orifice Area (EOA)

    Time frame: 2 years

Sponsors and collaborators

Lead sponsor

Edwards Lifesciences

Industry

Registry information

Official study title

Edwards SAPIEN XT Transcatheter Heart Valve Therapy for Intermediate and High Risk Patients

Acronym: PII A

Important dates

Study start
2011
Primary completion
2016
Study completion
2024
First posted
Mar 14, 2011
Registry last updated
Mar 7, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.