Skip to main content
OpenTrials
Active, Not Recruiting

NCT Number: NCT04489823

PARADIGM: Amplatzer Valvular Plug for PVL Closure

The Paradigm study is a prospective, multicenter, single arm study to demonstrate the safety and effectiveness of the Amplatzer Valvular Plug III (AVP III) as a treatment for clinically significant PVLs following surgical implant of a mechanical or biological heart valve implanted in the aortic or mitral position.

Active, Not Recruiting

This study is active but is not currently recruiting participants.

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Institut de Cardiologie de Montreal (Montreal Heart Inst.), Montreal, Quebec, Canada

Loading trial locations.

About this study

PARADIGM is a prospective, international, multi-center, single arm study to demonstrate the safety and effectiveness of the AVP III for percutaneous, transcatheter closure of paravalvular leak (PVL) occurring after aortic or mitral valve replacement with a surgically-implanted mechanical or bioprosthetic valve. The study will be conducted at approximately 25 clinical sites in the US, Europe, and Canada. A total of 200 subjects with a clinically significant PVL will undergo an AVP III implant procedure for PVL closure. Pre-procedural Baseline and follow-up assessments at Discharge, 30 days, 6 months and 1 year will include echocardiography, physical examinations, lab measurements and questionnaires to assess PVL severity, prosthetic valve function, hemolytic anemia, heart failure symptoms, and quality of life. Adverse events will be recorded throughout the study.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Subject is implanted with a mechanical or biological surgical valve in the aortic or mitral position
  • Note: Subjects in European countries can only be implanted with a mechanical valve in the aortic or mitral position
  • Subject has a clinically significant paravalvular leak with a severity grade of moderate or higher, associated with signs of heart failure and/or hemolysis necessitating recurring blood transfusions.
  • Subject has one clinically significant PVL defect that can be closed with a single AVP III as assessed pre-procedurally
  • Subject has provided written informed consent
  • Subject is ≥18 years old

Exclusion criteria

  • Subject has a rocking valve or extreme dehiscence of the prosthetic valve involving more than 40% of the sewing ring
  • Subject's PVL(s) originates from a transcatheter aortic or mitral valve replacement, or from rapid deployment or sutureless surgical replacement valves
  • Subject has a prosthetic aortic valve and prosthetic mitral valve which both have a clinically significant paravalvular leak.
  • Subject who is hemodynamically unstable or who cannot undergo an elective procedure
  • Subject with active endocarditis or other active infection
  • Subject has within the last 6 months a previously documented intracardiac mass, vegetation, tumor, or thrombus which would interfere with placement of the AVP III
  • Subject has inadequate vasculature for delivery of the AVP III
  • Subject has unsuitable anatomy for PVL closure using the AVP III (such as a PVL associated with an abscess cavity or a pseudoaneurysmal sac) or anatomy where the AVP III would interfere with other intracardiac or intravascular structures (such coronary ostia)
  • Subjects who are unable to receive intraprocedural anticoagulant therapy
  • Pregnant or nursing subjects or subjects who plan pregnancy during the clinical investigation follow-up period.
  • Presence of other anatomic or comorbid conditions, or other medical, social, or psychological conditions that, in the investigator's opinion, could limit the subject's ability to participate in the clinical investigation or to comply with follow-up requirements, or impact the scientific soundness of the clinical investigation results.
  • Life expectancy is less than 1 year in the opinion of the Investigator
  • Incapacitated individuals, defined as persons with mental illnesses or handicaps that impair their ability to provide informed consent, or individuals without legal authority to provide informed consent.
  • Individual who are currently participating in an investigational drug or device study that has not reached the primary endpoint or that may confound the results of this study

Treatment and study plan

AVP III

Device

Transcatheter closure of a paravalvular leak using AVP III

Primary outcomes

  1. Paravalvular leak closure success rate (percent of subjects)

    Time frame: 30 Days

    • Successful transcatheter placement in the intended location without interference
    • Reduction in paravalvular regurgitation severity by ≥ two grades
    • Freedom from intra-procedural death
    • Freedom from unplanned transcatheter or surgical re-intervention through 30 days post-implant.

Sponsors and collaborators

Lead sponsor

Abbott Medical Devices

Industry

Registry information

Official study title

PARADIGM PARAvalvular Leak Closure With the Amplatzer Valvular Plug occluDer for Interventional Transcatheter Closure for PVL With Surgical bioloGical and Mechanical Heart Valve

Acronym: PARADIGM

Important dates

Study start
2020
Primary completion
2025
Study completion
2026
First posted
Jul 28, 2020
Registry last updated
Feb 10, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.