Conexa Reconstructive Tissue Matrix
DeviceConexa will be placed as a soft tissue reinforcement in primary open or mini-open rotator cuff repair procedures
Other names: Conexa, Conexa TM
NCT Number: NCT01025037
The purpose of this study is to evaluate patient shoulder functional outcomes following rotator cuff repairs reinforced with a surgical mesh.
Looking for future studies?
Notify Me40 year–70 year
All sexes
Interventional
Not applicable
Orthopaedic Clinical Association, Phoenix, Arizona, United States
Conexa is a surgical mesh derived from porcine dermis and processed to produce an acellular dermal matrix. It is designed to perform as a surgical mesh for use as a soft tissue patch to reinforce soft tissue where weaknesses exist and for the surgical repair of damaged or ruptured soft tissue membranes. The purpose of this post-market clinical study is to collect safety and efficacy data when Conexa is used to repair torn tendons of the rotator cuff. Conexa will be used in accordance with its labeling for this clinical study.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
The patient:
Exclusion criteria
The patient:
Conexa will be placed as a soft tissue reinforcement in primary open or mini-open rotator cuff repair procedures
Other names: Conexa, Conexa TM
Time frame: baseline, post-op months 3, 6, 12, and 24
The ASES evaluation generally has a patient self-evaluation section and a physician assessment section. The patient self-evaluation section of the form contains visual analog scales for pain, instability, an activities of daily living (ADL) questionnaire. The physician assessment section includes an area to collect demographic information and assesses range of motion, specific physical signs, strength, and stability. A shoulder score can be derived from the visual analogue scale score for pain (50%) and the cumulative activities of daily living score (50%) (Richards, Bigliani, Gartsman, Iannotti, & Zuckerman, 1994). The ASES evaluation has a total of 100 points possible; with 100 being the best possible outcome, and 0 being the worst.
Time frame: baseline, post-op months 6, 12, and 24
The Constant-Murley Shoulder Score is a 100-point functional shoulder assessment tool in which higher scores reflect increased function. The subjective variables are pain (15 points) and function (Activities of Daily Living - sleep, work, recreation/sport) (20 points), for a total of 35 points. The objective variables are active range of motion (clinician assessment) (40 points) and strength (25 points), for a total of 65 points (Stiller & Uhl, 2005).
Time frame: baseline, post-op months 3, 6, 12, and 24
The Simple Shoulder Test (SST): a series of 12 "yes" or "no" questions the patient answers about the function of the involved shoulder; 2 questions relate to pain, 7 questions relate to function and 3 questions relate to range of motion. The answers to these questions (yes = 1, no = 0) provides a standardized way of recording the function of a shoulder before and after treatment (McClure & Michener, 2003). A score of 12 on the Simple Shoulder test represents the best possible outcome, while a score of 0 represents the worst possible outcome.
Time frame: Post-op months 6 and 12
Subjects will have MRI to assess healing of the repaired tendon at 6 and 12 months post-op. The rate of re-tear will be reported.
Two different definitions of a re-tear were used for the analysis.
Time frame: baseline, post-op months 6, 12, and 24
Time frame: All time points
Complications were summarized by reporting adverse events of special interest. AEs of special interest were defined as any reported infection (incision, wound, surgical site), seroma, hematoma, inflammation (surgical site, wound), and re-tear. The re-tear rate reported in this section is the number reported via AE or surgical intervention (not the MRI results). The AEs of special interest were chosen because they are in alignment with the potential complications listed on the product insert.
Stryker Trauma and Extremities
Industry
A Prospective, Multi-Center, Single-Arm Study to Assess Clinical Outcomes In Primary Open or Mini-Open Rotator Cuff Repair Using Conexa Graft Reinforcement
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07689383
PRP Injection, Rotator Cuff Injuries
Kifissia, Attica, Greece
View Trial DetailsNCT05499897
Postoperative Recovery, Rotator Cuff Injuries
Van, Bardakçı, Turkey (Türkiye)
View Trial DetailsNCT03295994
Rotator Cuff Injuries, Rotator Cuff Tear
Phoenix, Arizona, United States
View Trial DetailsNCT07455474
Neurologic Manifestations, Pain
Mammoth Lakes, California, United States
View Trial Details