University of Virginia Center for Diabetes Technology
Charlottesville, Virginia, 22904, United States
NCT Number: NCT01890954
The purpose of this study is to use a closed-loop Control-to-Range (CTR) system in adolescents with type 1 diabetes in an outpatient setting, and to evaluate the CTR system's ability to significantly improve blood glucose levels when an insulin bolus is omitted for a 30 gram carbohydrate snack and when insulin bolus is insufficient for the amount of carbohydrates consumed for a meal. The primary objective of this study is to use a closed-loop Control-to-Range (CTR) system to significantly reduce the post-prandial blood glucose excursion in adolescents with type 1 diabetes who omit and/or under-bolus insulin for either snacks or meals. Up to 20 subjects aged ≥13 and ≤18 years old will be tested.
Looking for future studies?
Notify Me13 year–18 year
All sexes
Interventional
Not applicable
Charlottesville, Virginia, 22904, United States
The purpose of this study is to use a closed-loop Control-to-Range (CTR) system in adolescents with type 1 diabetes in an outpatient setting, and to evaluate the CTR system's ability to significantly improve blood glucose levels when an insulin bolus is omitted for a 30 gram carbohydrate snack and when insulin bolus is insufficient for the amount of carbohydrates consumed for a meal. The CTR system is comprised of two algorithmic layers: (i) A Safety Supervision Module (SSM) which contains a predictive insulin request dampener (or brakes); (ii) a Range Correction Module (RCM), consisting in (a) a Hyperglycemia Mitigation System, and (b) Insulin on Board controller. Both modules will receive continuous glucose monitoring (CGM) and historical insulin delivery data. The SSM will monitor the safety of the subject's continuous subcutaneous insulin infusion pump (CSII) to prevent hypoglycemia. The RCM will be responsible for optimizing blood glucose (BG) control and mitigating postprandial hyperglycemic excursions through a mix of increased basal rate and, potentially, isolated insulin boluses. To run CTR, we will use our wearable artificial pancreas platform, known as DiAs (Diabetes Assistant) which consists of a smart phone running CTR and connected to standard insulin delivery and CGM devices.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Criteria for documented hyperglycemia (at least 1 criterion must be met):
Criteria for requiring insulin at diagnosis (at least 1 criterion must be met):
Exclusion criteria
RESTRICTIONS ON USE OF OTHER DRUGS OR TREATMENTS
Diabetes Assistance (DiAs) is a software residing in a Smartphone that contains the algorithms to regulate and control insulin deliveries (insulin bolus for: Basal rate, meal insulin and correction bolus) with inputs glucose values from a CGM and outputs insulin infusion by an insulin pump
Other names: Closed-Loop system
Time frame: 8 hours
Percentage of time that blood glucose (BG) values (measured with both finger-stick and CGM) were near normoglycemia (70-180 mg/dL).
University of Virginia
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06238778
Autoimmune Diseases, Diabetes Mellitus
Huntington Beach, California, United States
View Trial DetailsNCT06236256
Autoimmune Diseases, Diabetes Mellitus
Ramat Gan, Israel
View Trial DetailsNCT07711275
Autoimmune Diseases, Diabetes Mellitus
Istanbul, Turkey (Türkiye)
View Trial DetailsNCT03938324
Anemia, Anemia, Hemolytic
Durham, North Carolina, United States
View Trial Details