Skip to main content
OpenTrials
Completed

NCT Number: NCT05230992

Optimization of the Sensitivity of Histological Diagnosis of Pulmonary Nodules

In pulmonary oncology, the diagnosis of medium-sized pulmonary nodules (10 to 20 mm), too distal to be reached by standard bronchial fibroscopy but remaining proximal, is difficult.

There are 2 techniques: transthoracic puncture-biopsy under CT scan, usually performed by radiologists, and distal sampling guided by radial ultrasound mini-probe.

The limitations of the last technique could be overcome by the use of cryoprobes for sampling, as they would take more tissue by freezing.

Completed

Looking for future studies?

Notify Me

Key information

Conditions

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Pneumologie Elsan Santé Atlantique

Saint-Herblain, 44800, France

About this study

Concerning the interventional pneumology technique, it is performed in two steps: identification of the mass with the mini ultrasound probe and then distal sampling with a small biopsy forceps. Experience shows that there is a significant difference between the identification of the mass, which is fairly conclusive, and the samples, which are much less productive (60% at best), because it is necessary that :

  • that the tumor is endo-bronchial,
  • that the forceps open sufficiently to take samples by back and forth movements
  • but, on the other hand, that the bronchus is not too wide.

The use of cryoprobes would allow to take more tissue by freezing. The target tissue freezes at the tip of the cryoprobe and can be detached by traction. The longer the freezing time, the more tissue is removed.

Various studies of endo-bronchial visible tumor diagnosis have compared these 2 sampling techniques (cryoprobe and conventional biopsy forceps). The cryoextraction technique performed by cryoprobes has a superior diagnostic yield (compared to flexible forceps biopsy) due to large biopsies and superior quality of the biopsied tissue (very few crush artifacts or hematomas; the morphological structure remains intact).

In this context, it seems interesting to compare these 2 techniques but in distal situation, under ultrasound detection with the mini-probes, for tumors not visible in endo-bronchial. The first samples taken in the investigating center by this technique are convincing.

In the framework of this study, in the same operating time and after ultrasound identification of the tumor, biopsies will be performed by conventional forceps (5 samples) and by cryoprobes (3 samples) on the same site. The sequence of use of one or the other technique will be randomly selected. Thus, each patient is his own control.

This first pilot study will explore the feasibility, effectiveness and safety of this procedure. Depending on the results of this comparative study, a second study including more patients will validate this procedure.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patient with a tumor of any location with a draining bronchus (primary lung cancer or lung metastases)
  • Suspected lung nodule(s) with anatomical situation on mid 1/3 CT
  • Presence of at least one lung nodule of sufficient size on CT to allow for at least 8 tissue samples
  • Male or female aged ≥ 18 years
  • Mandatory membership in a health insurance plan
  • Patient who has been informed about the study and has signed the informed consent form

Exclusion criteria

  • Proximal or distal pulmonary nodule(s)
  • Pacemaker patient
  • Pregnant or nursing women
  • Patients under legal protection

Treatment and study plan

Cryoprobes First

Device

In this experimental group, the Cryoprobe is used in first and the classic biopsy forceps in a second time. This medical device under study is the flexible, single-use Cryoprobe, supplied in sterile condition, 1.1 mm in diameter, 1150 mm long, with extraction tube, 817 mm long (reference 20402-401), or 757 mm long (reference 20402-402) marketed. These cryoprobes are covered by a CE marking. Cryoprobes must be used in conjunction with the Erbecryo®2 device and its accessories.

Cryoprobes Second

Device

In this second experimental group, the same medical devices are used but in the other order.

Primary outcomes

  1. Validity of samples by cryoprobes

    Time frame: Within 24 hours after intervention

    Histological diagnosis from the material collected by cryoprobes and conventional forceps

Secondary outcomes

  1. Specificity, sensitivity, and predictive values of each technique

    Time frame: Within 24 hours after intervention

    specificity, sensitivity, predictive values

  2. Tolerance and safety of the samples taken

    Time frame: 15 Days after intervention

    Collection of adverse events for the duration of the study.

Sponsors and collaborators

Lead sponsor

Elsan

Other

Registry information

Official study title

Optimization of the Sensitivity of Histological Diagnosis of Pulmonary Nodules Using Cryoprobes Versus Standard Biopsy Forceps During Distal Sampling Guided by Mini Radial Ultrasound Probes

Acronym: CRYOPROBE

Important dates

Study start
2022
Primary completion
2023
Study completion
2023
First posted
Feb 9, 2022
Registry last updated
Feb 14, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.