NCT Number: NCT04015388

Optimization of Glycemic Control in the Hospital and Critical Care Setting

Continuous Glucose Monitoring collected using the iPro device, to complete a large dataset consisting of routine electronic health records, biological, neurophysiological, physiological, and glycemic data. This dataset will eventually contribute to the further development and optimization of a comprehensive simulation, training, and clinical decision support system designed to contribute the optimization of glycemic control in the hospital and critical care setting.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

About this study

Although recent advances in technology such as electronic medical records and continuous glucose monitoring provide enhanced monitoring capabilities, optimal glycemic control in the hospital and critical care setting is still extremely difficult to obtain. These technologies provide little to no identification of trends in data, and clinical decision support.

The goal of this research study was to collect data to support further development and optimization of a comprehensive clinical decision support system with simulation, training, and clinical decision support functionality. The system will also be designed to provide real-time performance measurement and feedback to ensure glycemic control is maintained at an optimal level.

The continuous glucose monitor (CGM) device utilized in this investigation was the iPro Recorder® (Medtronic Diabetes, Northridge, CA), a FDA approved monitoring device which reports glucose values every five minutes.

Subjects with a history of hyperglycemia or current hyperglycemia were identified either in the intensive care unit or prior to surgery. Upon enrollment of eligible patients in the study, CGM device was placed on subject's abdomen or thigh. The times logged by the CGM device were synchronized to achieve valid data pairing according to time. Subjects were visited as needed or at least twice in a 24-hour period to ensure that the devices were still in place and comfortable for the patient. After 72 hours of data collection, the CGM device was removed and the area of attachment cleaned.

Research staff collected medical history and standard of care glucose point of care obtained during subject's participation into the study. Other data from the patient's standard of care monitor, such as oxygen saturation levels, blood pressure, respiratory and heart rate, were collected as part of the patient's safety assessment assurance.

Data analysis will be completed offsite by investigators at Aptima, Inc. and their wholly owned subsidiary, Analytic Diabetic Systems, LLC. All patient data collected in this investigation was appropriately de-identified.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Male or Female, ≥ 18 years of age.
  • Subject able to provide written informed consent to participate in the study.
  • Female subject with a negative urine or serum pregnancy test, or not of childbearing potential, defined as surgically sterile due to bilateral tubal ligation, bilateral oophorectomy or hysterectomy; or are postmenopausal for at least 1 year.
  • Have a blood sugar value of >140 mg/dL or an glycosylated hemoglobin A1C (HbA1C) values >6.5% upon admission to the surgical Intensive Care Unit (ICU), medical ICU, or cardiovascular ICU, and have or not have been diagnosed with type 1 or type 2 diabetes.

Exclusion criteria

  • Subjects younger than 18 years old.
  • Subjects who are prisoners.
  • Subjects with known hypersensitivity to latex or tape.
  • Females who are pregnant or breastfeeding.
  • Subjects unable to provided informed consent.
  • Subjects unable to participate in the study for any reason in the opinion of the Principal Investigator.
  • Subjects enrolled in other research studies.

Treatment and study plan

iPro Continuous Glucose Monitoring

Device

iPro device is a continuous glucose monitoring (CGM) FDA approved device. This CGM device consists of a small recorder which reports glucose values every five minutes. This recorder is connected directly to a glucose sensor. The glucose-oxidase based sensor measures extracellular fluid in the subcutaneous tissue. The tiny and flexible sensors are typically inserted just beneath the skin, usually in the abdominal area, but can also be placed in the buttock, or anterior or lateral thigh.

Primary outcomes

  1. Evaluate performance of glucose predictive models, clinical decision support algorithms, and performance measures in simulated real-time setting.

    Time frame: Glucose levels collected since placement of the iPro device (Hour 0) until removal of the ipro device (Hour 72)

    Glucose measurements collected (mg/dL) in the iPro device will be further analyzed to create an algorithm to predict glucose changes (hyperglycemia or hypoglycemia).

Secondary outcomes

  1. Ensure data collected has considerable quantity of hypoglycemia, normoglycemia, and hyperglycemia for algorithm model development and optimization.

    Time frame: Glucose levels collected since placement of the iPro device (Hour 0) until removal of the ipro device (Hour 72)

    Glucose measurements collected (mg/dL) in the iPro device will be reviewed to confirmed that sufficient hyperglycemia or hypoglycemia episodes, as well as normal glucose values, were recorded. Available data will be used to create the algorithm to predict glucose changes.

  2. Further development of GlyCU system functionality (simulation, training, and clinical decision support capabilities) and identification of necessary steps for integration with the OSUWMC electronic health record database.

    Time frame: Glucose levels collected since placement of the iPro device (Hour 0) until removal of the ipro device (Hour 72)

    Correlate glucose measurements collected (mg/dL) in the iPro device with the glucose values collected as at standard of care for each study subject at the Ohio State University Wexner Medical Center (OSUWMC).

Sponsors and collaborators

Lead sponsor

Ohio State University

Other

Registry information

Official study title

Development of a Comprehensive Clinical Decision Support System and Educational Tool to Support Optimization of Glycemic Control in the Hospital and Critical Care Setting

Important dates

Study start
2014
Primary completion
2016
Study completion
2021
First posted
Jul 11, 2019
Registry last updated
Feb 11, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.