The optimal surgical approach in functional mitral regurgitation (MI) was questioned in favour for prosthetic replacement due to the reduced risk of recurrent MI . However, adjustable mitral rings may provide an alternative . In this first-in-man trial, a novel balloon-adjustable mitral-ring was assessed regarding clinical safety and feasibility. 5 patients will be enrolled according to the inclusion/ exclusion criteria and subsequently implanted with the study device. Study visits will be performed preoperatively, perioperatively, at discharge, at 30 days, 3 months and 6 months. Primary outcome parameter will be morbidity and mortality at 30 days following implantation.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Medical University of Vienna - Department of Surgery, Division of Cardiac Surgery

Vienna, 1090, Austria

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

Patients

  • with symptomatic severe Mitral Regurgitation (Carpentier's classification Type I or II P2) or in asymptomatic subjects with preserved Left Ventricle function and new onset of atrial fibrillation or pulmonary hypertension;
  • with EuroScore II < 4;
  • with Left Ventricle Ejection Fraction ≥ 55%;
  • with normal coronary angiogram (no significant lesions);
  • in satisfactory condition, based on the physical exam and investigator's experience, with a life expectancy above one year after the intervention;
  • willing to sign the informed consent;
  • willing to undergo all medical follow-up, echocardiography examinations and laboratory tests planned for the clinical investigation.

Exclusion criteria

Patients

  • of age < 18 years;
  • who are pregnant;
  • nursing mothers;
  • who require undergoing MRI examination;
  • involved in any other clinical investigation for drugs or devices;
  • with previous cardiac surgery or diaphragmatic lesion or previous hepatic surgery;
  • needing acute intervention;
  • with active endocarditis (or having had active endocarditis in the last three months);
  • with active myocarditis;
  • with heavily calcified mitral annulus or mitral valve anatomy with a high risk of valve replacement instead of valve repair;
  • needing any cardiac surgery other than mitral repair, tricuspid valve annuloplasty, pacemaker implantation (epicardial), exclusion of left appendage (with device or surgically) and Maze (or PVI) procedure;
  • with severe pulmonary hypertension (systolic pulmonary artery pressure at rest >65 mmHg);
  • with LV Ejection Fraction < 55%;
  • with creatinine level > 2.0 mg/100ml;
  • with echocardiographic measurements predicting SAM (see specific echocardiography protocol);
  • unable to take anticoagulation medications;
  • with a known untreatable allergy to contrast media or nickel;
  • with a major or progressive non-cardiac disease that, in the investigator's experience, results in a life expectancy shorter than 1 year, or for whom the implant of the device produces an unacceptable increase of risk;
  • having had an acute preoperative neurological deficit, myocardial infarction, or cardiac event that has not returned to baseline or stabilized ≥ 30 days prior to the planned surgical procedure.
  • unable to understand and sign the ICF in absence of legal protection
  • unable to read and write
  • anticipated ring size very small (26mm) or very large (36mm)

Treatment and study plan

Kephalios Device 1

Device

The Kephalios Device 1 is an adjustable annuloplasty ring, to be implanted by open surgery, having a hollow structure that comprises a flat rigid ring surrounding a deformable cage. The unique feature of the Kephalios Device 1 is that its annular shape and dimension can be finely adjusted percutaneously by an external actuator (three-balloon catheter) independently in the three areas corresponding to P1, P2 and P3

Primary outcomes

  1. Assessment of the safety of the Kephalios Device 1 in terms of mortality

    Time frame: 30 days after implant

    Valve-relatedness determined according to the STS/AATS/EACTS report - Akins, C. W., Miller, D. C., Turina, M. I., Kouchoukos, N. T., Blackstone, E. H., Grunkemeier, G. L., … Lytle, B. W. (2008). Guidelines for Reporting Mortality and Morbidity After Cardiac Valve Interventions. The Annals of Thoracic Surgery, 85(4), 1490-1495. https://doi.org/10.1016/j.athoracsur.2007.12.082alve-relatedness determined according to the STS/AATS/EACTS report - Akins, C. W., Miller, D. C., Turina, M. I., Kouchoukos, N. T., Blackstone, E. H., Grunkemeier, G. L., … Lytle, B. W. (2008). Guidelines for Reporting Mortality and Morbidity After Cardiac Valve Interventions. The Annals of Thoracic Surgery, 85(4), 1490-1495. https://doi.org/10.1016/j.athoracsur.2007.12.082

  2. Assessment of the safety of the Kephalios Device 1 in terms of morbidity

    Time frame: 30 days after implant

    Morbid events determined according to the STS/AATS/EACTS report - Akins, C. W., Miller, D. C., Turina, M. I., Kouchoukos, N. T., Blackstone, E. H., Grunkemeier, G. L., … Lytle, B. W. (2008). Guidelines for Reporting Mortality and Morbidity After Cardiac Valve Interventions. The Annals of Thoracic Surgery, 85(4), 1490-1495. https://doi.org/10.1016/j.athoracsur.2007.12.082

Secondary outcomes

  1. Safety in terms of mortality

    Time frame: 3 and 6 months after implant

    Valve-relatedness determined according to the STS/AATS/EACTS report - Akins, C. W., Miller, D. C., Turina, M. I., Kouchoukos, N. T., Blackstone, E. H., Grunkemeier, G. L., … Lytle, B. W. (2008). Guidelines for Reporting Mortality and Morbidity After Cardiac Valve Interventions. The Annals of Thoracic Surgery, 85(4), 1490-1495. https://doi.org/10.1016/j.athoracsur.2007.12.082

  2. Safety in terms of morbidity

    Time frame: 3 and 6 months after implant

    Morbid events determined according to the STS/AATS/EACTS report - Akins, C. W., Miller, D. C., Turina, M. I., Kouchoukos, N. T., Blackstone, E. H., Grunkemeier, G. L., … Lytle, B. W. (2008). Guidelines for Reporting Mortality and Morbidity After Cardiac Valve Interventions. The Annals of Thoracic Surgery, 85(4), 1490-1495. https://doi.org/10.1016/j.athoracsur.2007.12.082

  3. Effectiveness in terms of increase of mitral leaflets coaptation

    Time frame: in the immediate post-operative phase

    through data objectively measured through echocardiography

  4. Effectiveness in terms of reduction of Mitral Regurgitation

    Time frame: in the immediate post-operative phase

    through data objectively measured through echocardiography

  5. Effectiveness in terms of absence of recurrent Mitral Regurgitation

    Time frame: At hospital discharge or 30 days if subject is still hospitalized, and 6 months

    through data objectively measured through echocardiography

Sponsors and collaborators

Lead sponsor

Kephalios

Industry

Registry information

Official study title

OPtimisation of Surgical Repair for Treating Insufficiency of the MItral Valve - Safety Evaluation (OPTIMISE)

Important dates

Study start
2017
Primary completion
2018
Study completion
2018
First posted
Feb 15, 2019
Registry last updated
Feb 26, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.