The University of Tokyo
Tokyo, 158-8531, Japan
NCT Number: NCT02089711
This study is being initiated to create a normal database including measures of optic nerve head (ONH), peripapillary retinal nerve fiber layer (RNFL), and macula using the Heidelberg Spectralis OCT device. The range will be determined for each structural parameter across normal eyes in Japanese subjects, and the measurements stratified according to age.
Looking for future studies?
Notify Me18 year–90 year
All sexes
Observational
Tokyo, 158-8531, Japan
This multi-center, prospective, observational (non-interventional) study is the second in a series to measure structural parameters of the optic nerve head, the peripapillary retinal nerve fiber layer, and the macula using the Heidelberg Spectralis OCT device. This study is conducted in normal Japanese volunteers. The main goal of the study is to provide the range of these structural parameters in normal eyes. The study will include at least 224 (enrollment target: 249) normal volunteers; each study site will recruit 32 to 40 subjects with an age range of 18 to 90 years and an approximately equal number of females and males. All subjects will undergo Spectralis OCT imaging, biometric and ophthalmoscopic examination, disc photography and visual field testing in one single visit. All examinations performed on the subjects are non-significant risk procedures because the medical devices are cleared for marketing in Europe and in the U.S.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Minimum requirements are:
Note: Inability of a subject to perform one of the two scan patterns or insufficient image quality in one scan pattern does not exclude the subject or eye from the study.
Time frame: 12 months
This normal database will be used to determine if an unknown subject has measurement values "within normal limits" or "outside normal limits." It is planned to classify an eye "within normal limits" if the measurement value is greater than or equal to the 5th percentile of the normal distribution, and as "outside normal limits" if the measurement value is smaller than the 1st percentile (or larger than 99th percentile) of the normal distribution.
Heidelberg Engineering GmbH
Industry
Multi-center Study for Normal Database of Optic Nerve Head, Retinal Nerve Fiber Layer, and Macula Parameters With the Heidelberg Spectralis OCT, Study 2
Acronym: S-2013-2
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06068257
Breast Cancer, Breast Diseases