Hong ji HEE
Daegu, 42601, South Korea
NCT Number: NCT03785314
Intracranial pressure is measured indirectly using optic nerve sheath diameter with ultrasound. It is reported that epidural pressure varies according to different posture ( lateral decubitus vs. sitting position).
This study is designed to measure the optic nerve sheath diameter in lateral decubitus and sitting position, respectively.
Looking for future studies?
Notify Me20 year–80 year
All sexes
Interventional
Not applicable
Daegu, 42601, South Korea
According to previous study, injection of different volume of local anesthetics (1.0 ml/kg vs. 1.5 ml/kg) during caudal anesthesia, high volume of local anesthetics resulted in significant increase of intracranial pressure (ICP). Increase of ICP can reduce regional cerebral flow and oxygen saturation causing the safety of patients. In addition, increase of ICP can result in headache, syncope, and transient loss of visual acuity. Although it is very invasive method, ICP can be measured directly at the brain parenchyme. Among methods to measure the ICP indirectly, measurement of optic nerve sheath diameter using ultrasound is known to reflect the degree of ICP. It is reported that optic nerve sheath diameter increases when higher volume of medication is injected during epidural anesthesia. Previous reports showed that epidural pressure varies according to different posture. When epidural pressure was measured in patients of spinal stenosis, lumbar flexion showed lower epidural pressure than epidural pressure of lumbar extension. In addition, when epidural pressure was measured in the sitting position, it showed lower pressure than pressure of lateral decubitus.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
thoracic epidural catheterization with different posture
Time frame: Baseline, 10 minutes, 20 minutes, 40 minutes after the completion of the intervention
optic nerve sheath diameter change among 4 time period using ultrasound
Keimyung University Dongsan Medical Center
Other
Effect of Different Posture on Optic Nerve Sheath Diameter During Thoracic Epidural Catheterization
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.