Skip to main content
OpenTrials
Completed

NCT Number: NCT05930691

Optic Nerve Sheath Diameter and the Duration of Extracorporeal Life Support During Newborn Cardiac Surgery

Mortality rates for newborns with congenital heart disease (CHD) have dramatically decreased thanks to surgical methods and medical treatment improvements. Up to 70% of patients may have post- Extracorporeal life support (ECLS) cerebral dysfunction, which can result in long-term cognitive and motor impairment, first showing as brain edema and higher intracranial pressure (ICP). Optic Nerve Sheath Diameter (ONSD) is a non-invasive method of measuring Intracranial Pressure (ICP). The Primary Aim of this study is to identify the correlation between ONSD and ECLS time in newborns who get ECLS.

Completed

Looking for future studies?

Notify Me

Key information

Age range

1 day–28 day

Sex eligibility

All sexes

Study type

Observational

Primary location

Konya City Hospital

Konya, Karatay, 42020, Turkey (Türkiye)

About this study

INTRODUCTION Mortality rates for newborns with congenital heart disease (CHD) have dramatically decreased thanks to surgical methods and medical treatment improvements. As a result, more emphasis is being put on reducing neonatal cardiac surgery morbidity.

Extracorporeal life support (ECLS) is increasingly being given to children, particularly for cardiac causes, according to the Pediatric Extracorporeal Life Support Organization Registry's global report. However, up to 70% of patients may have post-ECLS cerebral dysfunction, which can result in long-term cognitive and motor impairment, first showing as brain edema and higher intracranial pressure (ICP). In addition, pediatric patients may have trouble being diagnosed with acute elevations in IİCP since the signs and symptoms are sometimes unclear.

The gold standard for measuring intracranial pressure (ICP) still involves invasive intracranial devices. In addition, ICP monitors have the potential to cause complications, including bleeding in 1.1-5.8% of cases, malfunction, in 6.3-40% of cases, or infection in 0-15% of cases, with a noticeable higher risk of bacterial colonization after five days.

The optic nerve sheath surrounds the Optic Nerve (ON) and covers the optic subarachnoid space, which is connected to the intracranial subarachnoid space area. Changes in intracranial pressure are thus straightly transferred to the optic nerve sheath. Therefore, Optic Nerve Sheath Diameter (ONSD) is a non-invasive method of measuring Intracranial Pressure (ICP).

Longer ECLS periods and aortic cross-clamp times have been linked to more frequent CT detection of cerebral edema, according to prior investigationsAccording to prior investigations, long ECLS periods, and aortic cross-clamp times have been linked to more frequent CT (computer tomography) detection of cerebral edema. However, there is currently no information on the relationship between these time points and the ONSD determined by ultrasound.

The Primary Aim of this study was to identify the correlation between ONSD and ECLS time in newborns who get ECLS. Specifically, we tested the primary hypothesis that more ECLS time means more ONSD valuable over the perioperative period. Our secondary aim was to investigate the relationship between ONSD and aortic cross-clamp time and operation time and also, operation time and preoperative and intraoperative perioperative ONSD variation for the ECLS period.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • ASA III or IV status newborn;
  • Have surgery for transposition of great arteries (TGA).

Exclusion criteria

  • All off-pump cardiac surgery;
  • Recent history of cerebrovascular accident or intracranial hypertension due to any cause;
  • History of increased ICP;
  • Ophthalmological diseases capable of affecting optic nerve diameters.

Treatment and study plan

Optic Nerve Sheath Diameter Measurement

Diagnostic Test

Prediction of intracranial pressure by using Ultrasonography on optic nerve sheath diameter.

Primary outcomes

  1. Correlation between optic nerve sheath diameter and extra corperal support life time.

    Time frame: Basal; the 15. minutes after aort cross clamp; the time of removing cross clamp; End of the operation.

    The Primary outcome of this study will be identifing ONSD in ECLS time in newborns.

Secondary outcomes

  1. Staticticaly meaningful between Cross clamp time and optic nerve sheath diameter

    Time frame: Basal; the 15. minutes after aort cross clamp; the time of removing cross clamp; End of the operation.

    Our secondary outcome will be ONSD in aortic cross-clamp time.

  2. Staticticaly meaningful between operation time and optic nerve sheath diameter

    Time frame: Basal; the 15. minutes after aort cross clamp; the time of removing cross clamp; End of the operation.

    Our secondary outcome will be ONSD in operation time.

  3. Perioperative ONSD variation for the ECLS period.

    Time frame: Basal; the 15. minutes after aort cross clamp; the time of removing cross clamp; End of the operation.

    Our secondary outcome will be ONSD variation for the ECLS period.

Sponsors and collaborators

Lead sponsor

Konya City Hospital

Other

Registry information

Official study title

Evaluation of the Association Between the Optic Nerve Sheath Diameter and Extracorporeal Life Support Time During Cardiac Surgery in Newborn

Important dates

Study start
2023
Primary completion
2023
Study completion
2023
First posted
Jul 5, 2023
Registry last updated
Jul 6, 2023

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.