IUCPQ - Laval Hospital
Québec, Quebec, G1V 4G5, Canada
NCT Number: NCT02144090
The purpose of this study is to assess the usability and safety of the Opsens OptoWire and Optomonitor in measuring fractional flow reserve (FFR) in patients with coronary artery disease who are undergoing a coronary angiogram.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Québec, Quebec, G1V 4G5, Canada
Fractional flow reserve (FFR) measurement involves determining the ratio between the maximum achievable blood flow in a diseased coronary artery and the theoretical maximum flow in a normal coronary artery. An FFR of 1.0 is widely accepted as normal. An FFR value lower than 0.75 - 0.80 is generally considered to be associated with myocardial ischemia (MI).
FFR is easily measured during routine coronary angiography by using a pressure wire to calculate the ratio between coronary pressure distal to a coronary artery stenosis and aortic pressure under conditions of maximum myocardial hyperemia. This ratio represents the potential decrease in coronary flow distal to the coronary stenosis.
Over the past decade, FFR measurement has been increasingly used in cardiac catheterization laboratories. It provides a quantitative assessment of the functional severity of a coronary artery stenosis identified during coronary angiography and cardiac catheterization.
Opsens, Inc. has developed a new pressure wire for use in determining FFR in coronary arteries; the OptoWire. The OptoWire is an instrumented guide wire with a fiber optic pressure sensor mounted 3.5 cm proximal to the tip. The Optowire measures blood pressure during diagnostic and/or interventional procedures when used in combination with the OptoMonitor.
The O2 study is a pilot study which aims to provide preliminary experience in human patients with coronary artery disease. The study data will also be used as part of design validation.
The O2 study is a prospective single arm study designed to assess the usability, functionality, and safety of the Optowire and Optomonitor in patients.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Fractional flow reserve measurement
Other names: Opsens Optowire and Optomonitor
Time frame: Patients will be followed through removal of the OptoWire from percutaneous insertion site and completion of the cardiac catheterization procedure (expected average <1hr)
Dedicated questionnaires will be used for such assessment
Time frame: Patients will be followed through removal of the OptoWire from percutaneous insertion site and completion of the cardiac catheterization procedure (expected average <1hr)
In selected cases, the operator may choose to perform FFR measurements using currently approved FFR wires. Values obtained with standard FFR wires and Optowire may therefore be compared.
Laval University
Other
Acronym: O2
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04929496
Angina Pectoris, Angina, Stable
Québec, Quebec, Canada
View Trial DetailsNCT03985241
Angina Pectoris, Angina, Stable
Bern, Switzerland
View Trial DetailsNCT01556126
Acute Myocardial Infarction, Angina Pectoris
Innsbruck, Austria
View Trial DetailsNCT02162056
Acute Myocardial Infarction, Angina Pectoris
Ulm, Germany
View Trial Details