Erasmus MC
Rotterdam, South Holland, 3015GD, Netherlands
NCT Number: NCT06815718
Rationale Following ICU discharge, intermittent vital sign monitoring may delay timely recognition of clinical deterioration and lead to unnecessary readmissions. This study proposes the use of the viQtor continuous monitoring device to measure pulse rate (PR), respiratory rate (RR), oxygen saturation (SpO2) and the activity index in post-ICU patients on general wards. The primary aim is to develop a continuous Early Warning Score (c-EWS), determine its optimal cut-off values. The secondairy outcome will be a comparison with the Modified Early Warning Score (MEWS). In addition, patient and nurse satisfaction, as well as technical feasibility, will be assessed.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Rotterdam, South Holland, 3015GD, Netherlands
Objective(s) Primary: To develop and optimize a c-EWS using viQtor data for early detection of clinical deterioration in post-ICU patients.
Secondary: To evaluate the c-EWS's predictive accuracy relative to MEWS, to assess user satisfaction (patients and nurses), and to determine the technical feasibility of the viQtor device.
Study type This is a single-center prospective observational cohort study at general wards in post-discharge ICU patients.
Study population A single-center prospective observational cohort study will include approximately 180 post-ICU patients and 20 nurses at the Erasmus MC.
Methods Over a four-month period (winter/spring 2024-2025), patients transferred from the ICU to a general ward will wear the viQtor device for up to 5 days. Concurrent standard care involves MEWS measurements three times daily. No clinical decisions will be based on viQtor measurements, ensuring no interference with standard care. The c-EWS will be retrospectively derived and assessed using ROC analyses to determine optimal cut-off values. Comparisons with MEWS will be descriptive. Patient feedback will be collected via a brief questionnaire at discharge, and a semi-structured focus group with participating nurses will provide insights into user experiences.
Burden and risks The wearable viQtor device is noninvasive, comfortable, and worn continuously without affecting patient care or activities. Minor skin irritation is the only anticipated risk. Nurses' participation is limited to the focus group.
Recruitment and consent Patients will be screened in the last 48 hours of their ICU stay. Following informed consent, the viQtor device will be applied at the moment of transfer to the general ward. All participants will be fully informed about study procedures, potential risks, and their right to withdraw. Nurses will be invited via email to participate in the focus group and will provide informed consent before participation.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: From enrollment to the end of monitoring in 5 days
A continuous early warning score (c-EWS) will be developed using the viQtor system to detect clinical deterioration in post-ICU patients on the general ward. Clinical deterioration is defined as an ICU consultation or a Rapid Response Team intervention. The optimal cut-off values for the c-EWS will be identified and evaluated using Receiver Operating Characteristic (ROC) curves and the Area Under the Curve (AUC) values.
Time frame: 5 days
The predictive accuracy of the optimized continuous Early Warning Score (c-EWS) compared to the Modified Early Warning Score (MEWS) in predicting ICU consultation or Rapid Response Team (RRT) intervention will be assessed using descriptive statistics.
Time frame: From enrollment to the end of monitoring (maximum 5 days).
The predictive accuracy of the optimized c-EWS compared to the MEWS in predicting in-hospital cardiac arrest, ICU readmission, and hospital mortality will be assessed using descriptive statistics.
Time frame: From enrollment to the end of monitoring (maximum 5 days).
The ability of the viQtor system's c-EWS to detect clinical deterioration within the eight hours preceding a documented deterioration event will be evaluated using descriptive statistics.
Time frame: end of monitoring after 5 days.
Patient acceptability of using the viQtor solution will be assessed using a 5-point Likert questionnaire Responses will be analyzed descriptively to determine levels of acceptability.
Time frame: At the end of the inclusion period
Nurses' perspectives on the usability and feasibility of the viQtor system will be evaluated through semi-structured focus groups. Results will be thematically analyzed to identify key themes regarding user experience and implementation challenges.
Erasmus Medical Center
Other
Acronym: ViQtor
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04292158
Early Warning Score
Genk, Limbourg, Belgium
View Trial DetailsNCT03690128
Clinical Deterioration, Disease Attributes
Copenhagen, Capital Region of Denmark, Denmark
View Trial DetailsNCT04507737
Early Warning Score, Hospital Rapid Response Team
Hillerød, Danmark, Denmark
View Trial DetailsNCT07051421
Early Warning Score
View Trial Details