Nu-Mask Intraoral Airway Device Versus Conventional Bag Valve Mask Ventilation Crossover Trial

This study comprised a randomized cross-over trial of ventilation using the NuMask Intraoral Mask versus conventional Bag Valve Mask in a cadaver model among United States Army combat medics.

Completed

Looking for future studies?

Notify Me

Key information

About this study

This study comprised a randomized crossover trial of adult United States Army combat medic volunteers participating in a cadaver laboratory as part of their training. The study took place in Bulverde, TX. Participants were randomized to perform cadaver ventilation first using either the novel Nu-MaskR intraoral device or conventional bag valve mask. A one handed seal technique was used to simulate single operator ventilation. Participants were responsible for mask placement while a ventilator delivered 10 breaths each with a standardized tidal volume of 750 ml. After a 5-minute washout period, they performed ventilation using the alternative device. The primary outcome measure was air leak as calculated by subtracting tidal volume received from tidal volume delivered as measured by the ventilator.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • United States Army Combat Medics

Exclusion criteria

  • Injuries precluding performance of bag valve mask ventilation

Treatment and study plan

NuMask Intraoral Airway Device

Device

NuMask Intraoral Airway Device

Bag Valve Mask

Device

Conventional bag valve mask

Primary outcomes

  1. Received Minute Volume (Liters) as Measured by Wright Respirometer

    Time frame: 1 Minute

    An Impact 731 Ventilator will be attached to a mask. Subjects will hold a mask seal on a cadaver for 100 seconds. The Impact 731 Ventilator will then deliver standardized tidal volumes of 750 cc (delivered tidal volume) 10 times at six second intervals. A Wright respirometer will then measure received tidal volume for each of these 10 breaths.

Sponsors and collaborators

Lead sponsor

Brooke Army Medical Center

Fed

Registry information

Official study title

Comparison of Air Leak During Ventilation With Nu-Mask Intraoral Airway Device Versus Conventional Bag Valve Mask in a Cadaver Model: A Randomized Crossover Trial

Important dates

Study start
2014
Primary completion
2015
Study completion
2015
First posted
Dec 10, 2015
Registry last updated
Aug 24, 2016