Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine
Shanghai, Shanghai Municipality, 200011, China
NCT Number: NCT07701226
This study evaluated a novel tracheostomy tube fixation device in post-tracheostomy patients with oral cancer. After tracheostomy, conventional fixation methods may be associated with skin pressure injury, wound contamination, frequent dressing changes, tube displacement, and patient discomfort. The novel fixation device was designed to provide stable tube fixation, protect the cervical skin, facilitate wound care, and improve patient comfort.
A total of 150 eligible patients who underwent tracheostomy were randomly assigned to a treatment group or a control group. Patients in the control group received routine tracheostomy care and conventional fixation. Patients in the treatment group received the novel self-adhesive bidirectional tracheostomy tube fixation device in addition to routine tracheostomy care.
The study assessed whether the novel fixation device could reduce tracheostomy-related complications, improve nursing efficiency, reduce the frequency and duration of wound care, improve neck comfort, and maintain safe tracheostomy tube fixation.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Shanghai, Shanghai Municipality, 200011, China
Tracheostomy is commonly performed in patients who require airway management after oral and maxillofacial head and neck tumor surgery. Stable fixation of the tracheostomy tube and appropriate wound care are important for maintaining airway safety, reducing local complications, and improving patient comfort. Conventional fixation methods, such as gauze ties or routine fixation straps, may become contaminated by blood or secretions, may cause friction or pressure on the cervical skin, and may require frequent replacement. These issues can increase nursing workload and may contribute to local skin injury, infection, tube displacement, or patient discomfort.
This randomized controlled trial was designed to evaluate the clinical application value and efficacy of a novel self-adhesive bidirectional tracheostomy tube fixation device. The device is intended to provide stable tracheostomy tube fixation while facilitating wound observation, dressing replacement, and daily nursing care.
Eligible patients were post-tracheostomy patients with oral cancer who were conscious, had adequate comprehension and communication ability, had intact cervical skin without infection or skin disease, and provided informed consent. Patients with pre-existing pressure injury, skin damage, allergy, or infection in the anterior cervical region before tracheostomy, pregnant women, minors, and patients with psychiatric disorders were excluded.
Participants were randomly assigned to two groups. The control group received routine tracheostomy care, including conventional tube fixation, nebulization therapy as prescribed, sputum suctioning as needed, regular inner cannula cleaning, and routine sterile gauze dressing care. The treatment group received routine tracheostomy care plus the novel self-adhesive bidirectional tracheostomy tube fixation device. The device was replaced once daily, or earlier if blood or exudate soaked two-thirds of the device.
The primary outcome was the occurrence of infection or inflammatory signs around the tracheostomy wound, including redness, swelling, heat, and pain. Secondary outcomes included the frequency of device or dressing replacement, duration of each wound care procedure, new cervical skin injury, tracheostomy tube displacement, and patient-reported neck comfort. Safety assessments included changes in oxygen saturation before and after use and the recording of adverse events, including tube dislodgement.
The purpose of this study was to determine whether the novel tracheostomy tube fixation device could improve nursing efficiency, reduce tracheostomy-related complications, and improve patient comfort compared with conventional fixation and routine tracheostomy care.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The novel self-adhesive bidirectional tracheostomy tube fixation device was used for tracheostomy tube fixation in addition to routine tracheostomy care. After drying the wound area, the device was placed between the patient and the tracheostomy tube, with the posterior side attached to the cervical skin. The anterior hook-and-loop components were passed through the fixation wings of the tracheostomy tube and adjusted to secure the tube. The device was replaced once daily, or earlier if blood or exudate soaked two-thirds of the device.
Routine tracheostomy care included conventional tracheostomy tube fixation, nebulization therapy as prescribed, sputum suctioning as needed, regular cleaning or replacement of the inner cannula, and sterile gauze dressing care. Conventional fixation was performed using gauze ties or routine fixation straps around the neck with appropriate tightness. The tracheostomy wound dressing was changed twice daily or earlier if blood or exudate soaked two-thirds of the gauze dressing.
Time frame: From intervention initiation to hospital discharge, up to 14 days
The occurrence of infection or inflammatory signs around the tracheostomy wound was assessed, including redness, swelling, heat, and pain around the tracheostomy site.
Time frame: From intervention initiation to hospital discharge, up to 14 days
The number of dressing or fixation device replacements was recorded. Replacement was performed once daily or earlier if blood or exudate soaked two-thirds of the dressing or device.
Time frame: From intervention initiation to hospital discharge, up to 14 days
The time required for each dressing or fixation device replacement procedure was recorded. Timing started when the dressing or device replacement began and ended after the fixation device or dressing was properly adjusted and secured.
Time frame: From postoperative day 1 to hospital discharge, up to 14 days
New cervical skin injury around the tracheostomy tube fixation area was recorded, including newly developed pressure injury, skin redness, skin breakdown, or other fixation-related skin damage.
Time frame: From intervention initiation to hospital discharge, up to 14 days
Tracheostomy tube displacement was assessed by marking the skin incision site as 0 cm. Tube movement of 0.8 cm or less was considered displacement according to the study protocol.
Time frame: From intervention initiation to hospital discharge, up to 14 days
Patient-reported neck comfort was assessed using a 0-to-10 scale. Conscious patients were asked to describe their wearing experience, with scores of 0 to 2 indicating comfort and scores of 3 to 10 indicating discomfort.
Time frame: Before and after device or dressing use during hospitalization, up to 14 days
Oxygen saturation was assessed before and after use of the tracheostomy tube fixation device or conventional fixation method to evaluate respiratory safety.
Time frame: From intervention initiation to hospital discharge, up to 14 days
Adverse events were recorded during the study period, including tracheostomy tube dislodgement and other device- or care-related adverse events. The time of occurrence, severity, duration, management, and outcome were documented.
Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine
Other
Effect of a Novel Tracheostomy Tube Fixation Device on Nursing Efficiency, Complication Rates, and Patient Comfort in Post-Tracheostomy Patients: A Randomized Controlled Trial
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07121517
Children in the Pediatric Intensive Care Unit or General Pediatric Care Unit Requiring a Central Venous Catheter, Endoscopy
Solna, Sweden
View Trial DetailsNCT07376525
Mechanical Ventilation, Respiration Disorders
Istanbul, Sisli, Turkey (Türkiye)
View Trial DetailsNCT07687342
Brain Diseases, Cardiovascular Diseases
Suzhou, Jiangsu, China
View Trial DetailsNCT07404592
Tracheostomy
Izmir, Bayrakli, Turkey (Türkiye)
View Trial Details