Skip to main content
OpenTrials
Completed

NCT Number: NCT05548140

Novel Motorized Spiral Enteroscopy Vs Single Balloon Enteroscopy In Patients With Small Bowel Disorders- A RCT

STUDY OBJECTIVES:

1. Primary objective: Rate of total enteroscopy (TER) by means of NMSE or SBE with: Complete antegrade approach or combined antegrade and retrograde approach 2. Secondary objective:

1. Technical success of anterograde and retrograde approach 2. Procedural time (minutes) 3. Depth of maximum insertion (cm) 4. Diagnostic yield 5. Therapeutic success 6. Adverse events

Completed

Looking for future studies?

Notify Me

Key information

Conditions

Age range

18 year–80 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Hardik Rughwani, Hyderabad, Other, India

Loading trial locations.

About this study

  • INTRODUCTION: Small-bowel (SB) disorders remain a diagnostic and therapeutic challenge for endoscopists because of its unfavourable anatomy for endoscopy. It is difficult to perform deep enteroscopy of the long redundant lengthy small intestine by the bare endoscope, most of the time operator end up in pushing the SB rather than traveling through it. Last two decades saw a paradigm shift in the management of SB disorders with the introduction of deep enteroscopy1-4, including Double-balloon enteroscopy (DBE, Fujifilm, Tokyo, Japan), Single-balloon enteroscopy5 (SBE, Olympus Medical Systems Corporation, Tokyo, Japan), and Spiral enteroscopy6 (SE, Spiral Medical, LCC, USA). The DBE and SBE techniques have had varied results as far as depth of insertion is concerned; moreover, both are time-consuming and have difficult ergonomics for the endoscopist which are a major limiting factor. Spiral enteroscopy (SE)6 was introduced in 2007, which was two-operator technique where a spiral-shaped over-tube (Discovery Small Bowel, DSB) was used to pleat the small bowel over the enteroscope by manual rotation of the over tube. Deep endoscopic access to the small bowel with all available methods is still a complex, cumbersome, time-consuming procedure, and requires high endoscopic skills. Novel Motorized Spiral Enteroscope7 (NMSE, Olympus Medical, Tokyo, Japan) is a recent advancement in the field of enteroscopy. This enteroscope works on the same principle as that of SE and comes with an integrated user controlled motor in the handle of the enteroscope. The integrated electric motor is controlled with the help of a footswitch for rotating a short spiral over tube to pleat and un-pleat the small bowel. This would increase the possibility to accelerate the procedure, facilitate insertion, and simplify the technique with a single operator. The procedure can be done both by antegrade and retrograde approaches. Data is scarce on the utility, safety and efficacy of Novel Motorized Spiral Enteroscopy (NMSE) for evaluation in patients with suspected SBD by both the routes of examination. Also there are no comparative studies between SBE and NMSE. Hence we have planned a Randomized controlled trial to compare both modalities.
  • RATIONALE: SBE is the standard procedure used for small bowel examination at our center. SBE in prior studies has shown diagnostic yield of 40-60%5 but very low TER (0-22%)4,10, with long procedure time. NMSE on the other hand has the advantage of greater TER and high diagnostic yield with shorter procedure times and minimal adverse events. Our study on NMSE11 has shown high diagnostic yield of 70%, with TER of 61% and total procedure time of around 40min. Various studies have shown the safety and efficacy of SBE and NMSE. One recent prospective study by Beyna9 et al. using NMSE for only antegrade enteroscopy showed total enteroscopy rate (TER) of 10.6% (14/132) with technical success of 97%. Majority of patients (74.2%) underwent NMSE for suspected GI bleeding. Overall diagnostic yield was 74.2% and endotherapy was done in 68.2% patients. In our study11 on NMSE, recently published, we have shown comparable technical success using both antegrade (92.85%) and retrograde (100%) routes. There was higher total enteroscopy rate of 60.6% with antegrade route showing 31.1%.This real-world scenario analysis showed that diagnostic yield of NMSE was 70% in those who successfully underwent enteroscopy and therapeutic procedures were done in almost one fourth of patients. Till date, there are no comparative data between NMSE and Balloon assisted enteroscopy techniques. Hence, we aim to compare NMSE and SBE in Randomized controlled trial.
  • STUDY METHODS / STUDY PROCEDURE / METHODS OF ASSESSMENT: Patients presenting with symptoms and signs suggestive of small bowel disorders will be admitted and investigated as per the latest guidelines2. Patients satisfying the inclusion and exclusion criteria will be randomized in one of the two arms and will undergo either NMSE or SBE. As per the presentation and indication patients in both arms will undergo antegrade or retrograde enteroscopy. Patients undergoing antegrade enteroscopy will also undergo retrograde enteroscopy if indicated in the same sitting with the aim of total enteroscopy. Patients will be managed according to the findings and will be discharged as per the conditions. Patients will be followed up in the OPD or telephonically 1 week and after 1 month of discharge.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients with small bowel disease with an indication for total enteroscopy with indeterminate imaging findings (as defined above)
  • Age > 18 years
  • Patients willing to give written consent

Exclusion criteria

  • Positive imaging findings (as defined)
  • Age < 18 years.
  • Contraindications for endoscopy due to comorbidities
  • Unable to provide written informed consent
  • Patients with known severe GI tract inflammation, intestinal obstruction, gastroesophageal varices that preclude a safe enteroscopy procedure
  • Coagulopathy or thrombocytopenia that couldn't be corrected by blood product transfusion
  • Pregnant patients
  • Health status American Society of Anaesthetist Classification (ASA) >3
  • Inability to tolerate sedation or general anaesthesia for any reason
  • Pediatrics patients (infants and toddlers)
  • Eosinophilic esophagitis

Treatment and study plan

Novel Motorized Spiral Enteroscopy

Device

This study involves performance of spiral enteroscopy in one arm and single balloon enteroscopy in the other arm in patients who satisfy inclusion criteria

Other names: Single Balloon Enteroscopy

Primary outcomes

  1. Rate of total enteroscopy (TER)

    Time frame: 1 year

    Number of cases in which total small bowel examination can be performed

Secondary outcomes

  1. Technical success of anterograde and retrograde approach

    Time frame: 1 year

    For anterograde approach, crossing of duodenal-jejunal flexure and for retrograde approach, crossing of ileo-caecal valve- describes technical success

  2. Procedural time (minutes)

    Time frame: 1 year

    Time taken for the entire procedure from start to end is procedural time

  3. Depth of maximum insertion (cm)

    Time frame: 1 year

    The depth till which the small bowel examination can be done. The examination can be done till we reach the expected lesion or till the scope stops further movement in small intestines

  4. Diagnostic yield

    Time frame: 1 year

    Diagnostic yield is defined as the percentage of procedures that can either confirm a diagnosis from previous studies or established a new definitive diagnosis at the anatomic location identified in previous studies or findings that could explain the clinical symptoms.

  5. Therapeutic success

    Time frame: 1 year

    Therapeutic success is defined as successful endoscopic interventions such as for GI bleeding, polypectomy, and so on.

  6. Adverse events

    Time frame: 1 year

    Adverse events are defined as minor or major. Minor adverse event was defined as superficial esophageal or colonic trauma, sore throat less than 72 hours in duration, abdominal discomfort lasting less than 48 hours, and mild nausea or vomiting not requiring hospital admission. Major adverse events were defined as perforation, significant bleeding requiring blood products, pancreatitis, or any hospital admission related to the procedure.

Sponsors and collaborators

Lead sponsor

Asian Institute of Gastroenterology, India

Other

Registry information

Official study title

Novel Motorized Spiral Enteroscopy Vs Single Balloon Enteroscopy In Patients With Small Bowel Disorders- A Randomized Controlled Trial

Acronym: MOTOR-AIG-01

Important dates

Study start
2022
Primary completion
2022
Study completion
2022
First posted
Sep 21, 2022
Registry last updated
Mar 27, 2023

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.