Prospective, randomized and controlled who will be conducted in Maisonneuve-Rosemont hospital and whose objectives are:
* To observe if the alterations of the NoL index and the standard monitoring (Mean Arterial Blood Pressure and Heart Rate) (using the variability of NoL index and standard monitoring, peak NoL index and peak standard monitoring values, and number of time passed over their respective threshold for nociceptive response) are more accentuated after laryngoscopy using the classical MAC blade versus single-use disposable blade of the Glidescope. * To observe the nociceptive response (using the variability of NoL index and standard monitoring, peak NoL index and peak standard monitoring values, and number of time passed over their respective threshold for nociceptive response) related to the insertion of endotracheal tube between vocal cords during the intubation.
Study plans to enroll 50 adult patients scheduled to undergo either general, gynecological, neurological, orthopedic, plastic or urological surgery under general anesthesia and who necessitate endotracheal intubation.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Montreal East, Quebec, H1T2M4, Canada
The purpose of this prospective pragmatic study is to evaluate the changes in NoL index, Heart Rate (HR) and Mean Arterial Blood Pressure (MABP) following the painful stimulus that represents laryngoscopy and intubation performed using either the single use blade of the Glidescope (group GVL) or the classically used MAC blade (group MAC). Calculation will be using the variations of NoL, HR and MABP, the peak values of these 3 parameters, and also the area above the curve of each parameter for 3 minutes (above the mean pre-stimulus values) and the amount of time (out of 3 minutes post-stimulus) those 3 parameters will be significantly higher than their respective pre-intubation mean thresholds.
In this prospective, randomized and controlled study, each patient will normally enter the operating room on the day of his surgery. All the normal monitors are installed, along with the NoL monitor. Pre-oxygenation (with 100% 02) is then started. While the patient is doing the pre-oxygenation, MABP, HR and NoL index measures are gathered to establish a baseline for each patient.
Once pre-oxygenation is over, induction with xylocaïne, propofol, remifentanil and rocuronium is given (according to patients' ideal weight). The end of the remifentanil bolus will correspond to the time 0 of our study. To be sure our patients are sleeping and on the same level of anesthetic medication during our study, perfusions of propofol and remifentanil will be administred until tracheal intubation and inhaled anesthetic gaz given. When the patient is asleep and apneic, a Guedel device (chosen according to patient weight and height) is inserted in the mouth, as in usual practice, to ease the manual ventilation until the laryngoscopy. The patient is then ventilated with a face mask. After 5 minutes, the first laryngoscopy is performed (either with GlideScope blade or MAC blade according to randomization). Once a Cormack-Lehane grade I or II is obtained, the movement is ended, and the patient is ventilated again for 4 minutes with the Guedel. If the procedure takes more than 30 seconds to perform (if no view of grade I or II is seen before 30 seconds), the laryngoscopy is considered difficult and the patient will be excluded from the study. At T9 (9 minutes after T0), the second laryngoscopy is done (either with the MacIntosh blade or the GVL blade - the tool used for the second laryngoscopy will always be the one that wasn't used at the first laryngoscopy). The size of the MacIntosh blade (MAC 3 or 4) or the disposable blade for GVL is decided according to the patient size (height and weight). At the second laryngoscopy, the endotracheal tube is still not inserted, only the procedure of laryngoscopy is done, so that we can evaluate the hemodynamic and the NoL index responses related only to the type of device used for laryngoscopy. Then, the operator replaces the Guedel and ventilates the patient with a facemask (100% O2) for 4 more minutes, without stimulating the patient otherwise. At T13 (13 minutes after T0), the third laryngoscopy will be performed (either with the single-use blade for GlideScope or the MacIntosh blade - according to randomization). This time, the ETT is inserted (size 7 or 8, depending on the size and sex of the patient). After ETT insertion, the patient is then ventilated with the anesthesia machine and the perfusions of propofol/remifentanil is discontinued.
Monitors will record HR, MABP and NoL index until 3 minutes after the ETT insertion (end of the study). All the data will be electronically registered every 5 seconds and exported in an anonymous manner for each patient into an excel file at the end of the study.
In this study, each patient is exposed to three laryngoscopies; one with the single use blade for the GlideScope, one with the Macintosh laryngoscopy and one with the ETT insertion (laryngoscopy done with either GlideScope or Macintosh according to randomization). Hence, each patient will be its own control. It will then be more reliable to compare the differences in nociceptive response according to the tool used for laryngoscopy.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Non-inlusion Criteria:
Exclusion criteria
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the variation of NoL (delta NoL) after laryngoscopy using the single use blade for Glidescope (GVL) versus MAC blade (MAC) in anesthetized patients
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the variation of the standard hemodynamic parameter after laryngoscopy using the single use blade for Glidescope (GVL) versus MAC blade (MAC) in anesthetized patients
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the variation of the standard hemodynamic parameter after laryngoscopy using the single use blade for Glidescope (GVL) versus MAC blade (MAC) in anesthetized patients
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the peak value of NoL after laryngoscopy in the GVL group versus the MAC group
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the peak value of standard hemodynamic parameter after laryngoscopy in the GVL group versus the MAC group
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the peak value of standard hemodynamic parameter after laryngoscopy in the GVL group versus the MAC group
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the amount of time (in seconds) the MABP will spend over its respective mean pre-stimulus value after laryngoscopy with GVL versus MAC
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the amount of time (in seconds) the NoL will spend over its respective mean pre-stimulus values after laryngoscopy with GVL versus MAC
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the amount of time (in seconds) the HR will spend over its respective mean pre-stimulus value after laryngoscopy with GVL versus MAC
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the area under the curve between GVL versus MAC-Dl laryngoscopy that NoL spends above its baseline value and calculated for the 3 minutes after the stimulus
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the area under the curve between GVL versus MAC-Dl laryngoscopy that HR spends above its baseline value and calculated for the 3 minutes after the stimulus
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the area under the curve between GVL versus MAC-Dl laryngoscopy that MABP spends above its baseline value and calculated for the 3 minutes after the stimulus
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the variation of NoL after the laryngoscopy alone versus laryngoscopy + endotracheal tube (ETT) insertion in the GVL and the Mac group
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the variation of HR after the laryngoscopy versus laryngoscopy + endotracheal tube (ETT) insertion in the GVL and the Mac group
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the variation of MABP after the laryngoscopy versus laryngoscopy + endotracheal tube (ETT) insertion in the GVL and the Mac group
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the peak value of NoL after the laryngoscopy + endotracheal tube (ETT) insertion in the GVL and the Mac group
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the peak value of HR after the laryngoscopy + endotracheal tube (ETT) insertion in the GVL and the Mac group
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the peak value of MABP after the laryngoscopy + endotracheal tube (ETT) insertion in the GVL and the Mac group
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the AUC of NoL after the laryngoscopy + endotracheal tube (ETT) insertion in the GVL and the Mac group
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the AUC of HR after the laryngoscopy + endotracheal tube (ETT) insertion in the GVL and the Mac group
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the AUC of MABP after the laryngoscopy + endotracheal tube (ETT) insertion in the GVL and the Mac group
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the influence of the order of the tool used for laryngoscopies with the variation of NoL, after laryngoscopy using the single use blade for Glidescope (GVL) and MAC blade (MAC) in anesthetized patients
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the influence of the order of the tool used for laryngoscopies with the variation of HR, after laryngoscopy using the single use blade for Glidescope (GVL) and MAC blade (MAC) in anesthetized patients
Time frame: From 30 seconds before to 3 minutes after each laryngoscopy (3 total) for each patient
To compare the influence of the order of the tool used for laryngoscopies with the variation of MABP, after laryngoscopy using the single use blade for Glidescope (GVL) and MAC blade (MAC) in anesthetized patients
Ciusss de L'Est de l'Île de Montréal
Other
NoL Index, Heart Rate and Mean Arterial Blood Pressure Responses to Tracheal Intubation Performed With MacIntosh Blade Versus Glidescope
Acronym: NoLint
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03709979
Anesthesia, Intubation
Malatya, Turkey (Türkiye)
View Trial DetailsNCT06815952
Anesthesia, Intubation
Beirut, Lebanon
View Trial DetailsNCT04701762
Intubation, Laryngoscopy
Cleveland, Ohio, United States
View Trial DetailsNCT06249659
Anesthesia, Complication,Postoperative
Clermont-Ferrand, France
View Trial Details