Istituto Oncologico Veneto
Padova, 35128, Italy
NCT Number: NCT06595498
The study aims to evaluate the Plasma-SeqSensei™ Solid Cancer IVD Kit NGS diagnostic test (Sysmex) before its introduction into routine diagnostics. This is a test for research of EGFR mutations in cfDNA that needs to be evaluated in a patient population with lung adenocarcinoma already characterized for EGFR mutations by a molecular test of reference. The proposed study does not present any risk to participants.
This study is active but is not currently recruiting participants.
Notify Me18 year and older
All sexes
Interventional
Not applicable
Padova, 35128, Italy
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The patients' blood has already been collected in Streck tubes for circulating DNA and the plasma has been stored at -80°C as per the procedure for the routine diagnostic test cobas EGFR Mutation Test v2. No further blood sampling will be required from patients. Circulating DNA/RNA will be extracted from 2-5 ml of plasma. The extracted cfDNA will be quantified. The libraries will be prepared using the NGS Plasma-SeqSensei™ Solid Cancer IVD Kit (Sysmex) and will be evaluated at the Tapestation (Agilent) to verify their quality and quantity using D1000 Screentapes. The libraries consisting of approximately 16 samples each will then be sequenced on an Illumina NextSeq 500 sequencer using the Illumina NextSeq 500/550 Mid Output Kit v2.5 (150 Cycles). Data analysis will be performed using Plasma-SeqSensei™ IVD Software (Sysmex).
The patients' blood has already been collected in Streck tubes for circulating DNA and the plasma has been stored at -80°C as per the procedure for the routine diagnostic test cobas EGFR Mutation Test v2. No further blood sampling will be required from patients. Circulating DNA/RNA will be extracted from 2-5 ml of plasma. The extracted cfDNA will be quantified. The libraries will be prepared using the cobas® EGFR Mutation Test v2 (Roche) and will be evaluated at the Tapestation (Agilent) to verify their quality and quantity using D1000 Screentapes. The libraries consisting of approximately 16 samples each will then be sequenced on an Illumina NextSeq 500 sequencer using the Illumina NextSeq 500/550 Mid Output Kit v2.5 (150 Cycles).
Time frame: Through study completion, an average of 1 year
Evaluate the capability of the NGS test Plasma-SeqSensei™ Solid Cancer IVD Kit (Sysmex) in detecting a greater number of EGFR mutations compared to the diagnostic test routine cobas® EGFR Mutation Test v2 (Roche)
Time frame: Through study completion, an average of 1 year
Check if the NGS Plasma-SeqSensei™ Solid Cancer IVD Kit (Sysmex) is comparable to conventional test (cobas® EGFR MutationTest v2 (Roche)) in the detection of the mutational status of EGFR
Istituto Oncologico Veneto IRCCS
Other
Evaluation of an Ultrasensitive Next Generation Sequencing Method for the Detection of EGFR Gene Mutations in the Plasma of Patients With Lung Cancer
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02392507
Bronchial Neoplasms, Carcinoma
Orlando, Florida, United States
View Trial DetailsNCT04198766
Adenocarcinoma, Bronchial Neoplasms
Duarte, California, United States
View Trial DetailsNCT07489066
Bronchial Neoplasms, Carcinoma
Hinsdale, Illinois, United States
View Trial DetailsNCT07222566
Advanced Non-Small Cell Lung Cancer, Bronchial Neoplasms
Bullhead City, Arizona, United States
View Trial Details