Skip to main content
OpenTrials
Completed

NCT Number: NCT04826809

New Reusable Mask Design With Superior Filtration and Fit

This study will test the filtration, air leak, and breathability of a newly designed fully washable mask developed by Dr. Nordell with the Mayo Clinic. This mask is theorized to be a superior alternative to other respirators currently used when one-time-use N95 masks are unavailable.

Completed

Looking for future studies?

Notify Me

Key information

About this study

The purpose of this study is to determine potential effectiveness of a new, reusable mask against SARS-CoV-2 and other microbes. This requires filtering down to at least 0.3 microns, as the SARS-CoV-2 virus is on average 0.25-0.5 microns in diameter.

Dr. Nordell has developed a machine-washable mask which shows potential to be significantly more effective than other masks on the market. It uses a fabric that is machine washable, without need for a filter or replaceable component. This fabric, Evolon-100 or E-100, is a microfilament fabric produced by a private company outside of the USA (and is therefore not yet FDA approved as of December 2020).

Unofficial data shows this mask passes the "N95 fit test" before and after multiple washes on the majority of individuals tested, and the material used in Dr. Nordell's design filters 93-96% of 0.3 micron particles. For reference, the N95 mask used in the hospital (whenever concern for potential exposure to COVID-19 or similar contagion exists) filters 95% of 0.3 micron particles when factoring in air leak, assessed with the "fit test." Voluntary survey of users also shows it is more comfortable than other masks, including the N95. This mask is also reported to be breathable even after prolonged use.

This mask design addresses every factor in respirator design. The design intentionally uses pleats to increase the effective mask surface area while decreasing the seal perimeter, resulting in increased air flow, lower pressure drop, and increased filtration efficiency. The investigators propose that it has a higher filtration ability than other washable fabrics tested, filtering at least 93% of 0.3 micron particles, even up to 96%. It also helps prevent air leak, a large factor limiting efficacy of most non-standard masks. It is easy to don and doff, and it is very easy to clean and disinfect. This material can be washed multiple times in a standard washing machine without reducing its effectiveness. And finally, it is very affordable, with materials for one mask costing less than $1.50. All materials used beyond this specific fabric are easily purchased on the internet or in a fabric store.

Upon completion of this research, the investigators hope to demonstrate that this mask is a superior alternative in multiple settings, including hospitals in developing countries with little or no N95 mask access, non-hospital settings such as businesses and schools, as well as for the general population, especially those with high risk for COVID-related complications.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Current employee of Mayo Clinic Health System-Mankato
  • Passed N95 fit test within the past year
  • No medical history of: high blood pressure, current or recent pneumonia or upper respiratory infection, and no uncontrolled chronic asthma
  • Ideally with wide representation of genders, race, age, BMI, occupation/role in hospital.
  • Willing and able to provde verbal consent.

Exclusion criteria

  • History of uncontrolled asthma, pneumonia, or hypertension.

Treatment and study plan

N95 mask

Device

Standard 1870 N95 one time use mask

Nordell single E-100 layer mask

Device

Nordell mask design using one layer of E-100 fabric plus cotton fabric overlay

Nordell double E-100 layer mask

Device

Nordell mask design using two layers of E-100 fabric

Primary outcomes

  1. Comparison of Fit Tests

    Time frame: Baseline

    Number of participants to pass the respirator fit testing using Bitrix solution. If participants do not smell or taste the solution while wearing the respirator it is considered passed.

  2. Comfort Level of Nordell Double E-100 Layer Mask

    Time frame: Baseline

    Measured by a self-reported questionnaire that rates the comfort level of the Nordell Double E-100 layer mask on a scale from 0 to 5 (0 is the most uncomfortable mask ever worn, 5 is the best, most comfortable mask)

  3. Ability to Breathe With Nordell Double E-100 Layer Mask

    Time frame: Baseline

    Measured by a self-reported questionnaire that rates ability to breathe comfortably while wearing the Nordell Double E-100 Layer Mask, from 0 (not able to breathe at all) to 5 (just as easy to breathe as not wearing any mask)

Sponsors and collaborators

Lead sponsor

Mayo Clinic

Other

Registry information

Official study title

A New Fully-reusable, Affordable, Comfortable Mask Design With Superior Filtration and Fit for Use During Respirator Shortages and Pandemics

Important dates

Study start
2021
Primary completion
2022
Study completion
2022
First posted
Apr 1, 2021
Registry last updated
Jul 7, 2023

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.