Measurement of the length of the right main stem bronchus
ProcedureMeasurement of the length of the right main stem bronchus on CT-Scan
NCT Number: NCT02366455
The right-sided double lumen endobronchial tube (R-DLT) is seldom. The principal cause of reticence for using the R-DLT are the difficult positioning of its lateral orifice in front of the origin of the right upper lobe (RUL) and the variability of the length of the right main stem bronchus (RMSB). Both the angle between the right upper lobe (RUL) bronchus origin and the RMSB and the length of the RMSB can be measured with high resolution CT-scan. These measures can be useful in clinical practice as they help to determine when a R-DLT should not be used or used with caution when facing a large variation of the angle of the RUL or a proximal implantation of a RUL bronchus .
Looking for future studies?
Notify Me35 year–85 year
All sexes
Observational
Since the introduction in the early '80s of the disposable double-lumen endobronchial tube (DLT), combined with the use of fiberoptic bronchoscopy (FOB) to confirm its positioning, some controversies have aroused; the main concern being the use of the right-sided double-lumen endobronchial tube (R-DLT). Alongside this persistent controversy, the anatomy of the right tracheo-bronchial tree seems to be the principal cause of reticence for using the R-DLT. Compared to the left main stem bronchus, this anatomy is relatively complex and can be divided in two issues: 1) the variable length of the right main-stem bronchus (RMSB) and consequently, the variable level of insertion of the right upper lobe (RUL) bronchus on the lateral part of the RMSB and 2) the alignment of the lateral orifice of the R-DLT in regard of the RUL bronchus origin. A as part of an extensive study of the tracheo-bronchial tree anatomy with high resolution CT-scan, we had the opportunity to measure differently the length of the main stem right bronchus and the angulation between the RUL bronchus origin and the lateral aspect of the right side main stem bronchus.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Measurement of the length of the right main stem bronchus on CT-Scan
Measurement of the right upper lobe bronchus antero-posterior angulation on CT-Scan
Time frame: 1 day
Time frame: 1 day
Laval University
Other
Knowing the Right Upper Lobe Anatomy Allows for the Efficient Use of the Right-sided Double Lumen Endobronchial Tube
Acronym: ATB
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.