Theranica Bio-Elewctronics Inc
Bridgewater, New Jersey, 08807, United States
NCT Number: NCT06738056
This is a post-marketing real-world evidence study investigates long-term treatment with the Remote Electrical Neuromodulation (REN) wearable Nerivio device over 3 consecutive years in patients with migraine.
Looking for future studies?
Notify Me12 year and older
All sexes
Observational
Bridgewater, New Jersey, 08807, United States
The REN device (Nerivio by Theranica, Israel) is a neuromodulation device approved by the FDA for acute and/or preventive treatment of migraine in patients 8 years old and above. It is a wearable device applied to the upper arm. It stimulates C and Aδ noxious fibers. The REN device is operated by a designated app that is downloaded to the user's phone prior first use of the Nerivio device.
As part of the sign-up process for the Nerivio app, all patients accept the terms of use which specifies that providing personal information is done on their own free will and that their de-identified data may be used for research purposes. Users are not obligated to provide personal information and could treat without providing any feedback. The app includes a secure, personal migraine diary, which enables patients to record and track their migraine and other headaches. At the beginning of each treatment, and again 2 hours after the start of treatment, patients are prompted to record their symptoms, including pain level (none, mild, moderate, severe), functional disability (none, mild limitation, moderate limitation, severe limitation), and an indication of which medications, if any, were taken within that 2-hour time window.
This post-marketing RWE study investigates the safety and efficacy of the Nerivio treatment by analyzing data of patients who used the Nerivio device for consecutive 3 years: the following outcome will be assessed:
Primary endpoint:
Secondary endpoints:
Together, these four objectives provide a comprehensive evaluation of the long-term tolerability, safety, and efficacy of the Nerivio device using a real-world dataset.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
None
Remote electrical neuromodulation (REN) wearable device for the treatment of migraine. The device delivers electrical stimulation to the upper arm to induce conditioned pain modulation (CPM) that activates a descending endogenous analgesic mechanism. The treatment is self-administered and controlled by a smartphone application.
Time frame: 3 Years
No clinically meaningful change in treatment intensity between the years (defined as change of less than 2.5 of treatment intensity units between consecutive years).
Time frame: 3 Years
Constant proportion of subjects reporting relief from headache pain at 2 hours post-treatment in at least 50% of their treatments between the years.
Pain relief is defined as an improvement from severe or moderate pain at treatment initiation to mild or no pain.
Pain level is reported using a 4-point Likert scale (0 - No pain, 1 - Mild pain, 2 - Moderate pain,3- Severe pain)
Time frame: 3 Years
Constant proportion of subjects reporting freedom from headache pain at 2 hours post-treatment in at least 50% of their treatments between the years.
Pain freedom is defined as the disappearance of pain from severe, moderate, or mild headaches at treatment initiation to no pain 2 hours later.
Time frame: 3 Years
Constant proportion of subjects reporting functional disability at the beginning of the treatment and reported improvement of at least one level of functional disability at 2 hours post-treatment in at least 50% of their treatments between the years.
Functional disability level is reported using a 4-point Likert scale (0-No limitation, 1-Some limitation, 2-Moderate limitation, 3-Severe limitation)
Time frame: 3 Years
Constant proportion of subjects reporting functional disability at the beginning of the treatment and reported no functional disability at 2 hours post-treatment in at least 50% of their treatments between the years.
Functional disability level is reported using a 4-point Likert scale (0-No limitation, 1-Some limitation, 2-Moderate limitation, 3-Severe limitation).
Time frame: 3 years
Constant proportion of subjects reporting presence of associated symptoms (photophobia, phonophobia, nausea and/or vomiting) at the beginning of the treatment and reporting freedom from associated symptoms at 2 hours post-treatment in at least 50% of their treatments between the years.
Associated symptoms are reported as present or absent
Time frame: 3 Years
Constant average number of monthly Nerivio treatments per year between the years.
Time frame: 3 Years
Incidence of device-related adverse events reported by subjects
Theranica
Industry
Real-World Evidence (RWE) Data Analysis of 3-year Usage of Nerivio, a Remote Electrical Neurostimulation (REN) Device In Patients With Migraine
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07336420
Acute Treatment of Migraine, Brain Diseases
Bridgewater, New Jersey, United States
View Trial DetailsNCT06976723
Acute Treatment of Migraine, Brain Diseases
Bridgewater, New Jersey, United States
View Trial DetailsNCT01430442
Acute Treatment of Migraine, Brain Diseases
Scottsdale, Arizona, United States
View Trial DetailsNCT04530110
Brain Diseases, Central Nervous System Diseases
Aurora, Colorado, United States
View Trial Details