Natrecor for Pulmonary Hypertension in Lung Transplants

This study seeks to demonstrate that Natrecor® (nesiritide) is safe and effective and has a favorable hemodynamic profile in lung transplant recipients that will allow for the avoidance of inhaled nitric oxide (iNO) use. It is estimated that the use of nesiritide will decrease the otherwise historically mandated use of iNO by 50%, as compared to the necessity of iNO use by matched historical controls.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 4

Primary location

University of Wisconsin Hospital and Clinics

Madison, Wisconsin, 53792, United States

About this study

A condition called ischemic reperfusion injury (IRI) occurs in all lung transplants. The amount of reperfusion injury varies from person to person. IRI occurs when the blood supply to tissue (in this case, transplanted lung(s)) is decreased and then is restored. IRI can cause a decrease in function in a newly transplanted lung. When this occurs, or when people have pulmonary hypertension (high blood pressure in your lungs), doctors use Nitric Oxide to improve the pressure and blood supply to the transplanted lung. Nitric Oxide (NO) is given by inhalation while patients are on a ventilator (breathing machine). Because NO must be given by a ventilator and because patients on ventilators must be in an intensive care unit, the cost of treating people with NO is very high. NO can also cause rebound pulmonary hypertension (high blood pressure in the lungs that reoccurs) when it is stopped. Because of these reasons, doctors are looking for other treatments for IRI and pulmonary hypertension. A drug called Natrecor has been shown to reduce pulmonary pressures in heart transplant patients. Doctors believe it may be helpful to lung transplant patients as well.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Single or double lung transplant or heart/lung transplant recipient
  • Planned use of Natrecor
  • Pulmonary artery (PA) systolic pressures > 35

Exclusion criteria

  • Previous lung transplant
  • Use of Prolastin after pneumonectomy
  • Mean arterial pressure of < 55
  • Known allergy or sensitivity to nesiritide
  • Females of childbearing potential with a positive pregnancy test or women who are breast feeding
  • Use of nesiritide, for any reason, within 30 days prior to transplant

Treatment and study plan

Natrecor

Drug

Natrecor will be initiated as a bolus dose of 2 mcg/kg followed by a continuous infusion via infusion pump after induction of anesthesia but prior to incision. Natrecor infusion will be started at the recommended rate of 0.01mcg/kg/min. This dose may be adjusted by the investigator(s) only based on hemodynamic monitoring and pulmonary parameters. Study drug will be infused for a minimum of 24 hours and a maximum of 96 hours.

Other names: nesiritide

Primary outcomes

  1. To evaluate the safety and efficacy of Natrecor® in reducing nitric oxide used perioperatively in patients undergoing single or double lung transplantation who have or are at risk for developing pulmonary hypertension

Secondary outcomes

  1. To compare total cost-effective evaluation between patients receiving Natrecor and those who received iNO

  2. To compare length of stay in the Intensive Care Unit (ICU)

  3. To compare renal function as defined by peak serum creatinine and calculated creatinine clearance during the first 72 hours post-transplant

  4. To compare necessity of CPB between Natrecor® versus nitric oxide

  5. To compare hemodynamic parameters

  6. To compare length of stay (total)

  7. To compare time to dry weight

  8. To compare duration of mechanical ventilation

  9. To compare pulmonary parameters

  10. To compare IRI via chest x-ray and PAO2/FIO2 ratio

Sponsors and collaborators

Lead sponsor

University of Wisconsin, Madison

Other

Registry information

Official study title

Natrecor® (Nesiritide) as a Nitric Oxide Sparing Agent in Patients Undergoing Lung Transplantation

Important dates

Study start
2005
Primary completion
2006
Study completion
2006
First posted
Sep 20, 2005
Registry last updated
Oct 14, 2015

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.