Skip to main content
OpenTrials
Active, Not Recruiting

NCT Number: NCT05355792

Multicenter Study to Evaluate the Clinical Outcome of the OmniTaper EV Implant in Single Tooth Restorations

This clinical study, funded by the company Dentsply Sirona, is being carried out to see if the newly developed tooth implant "OmniTaper EV" is safe, effective and functions as intended when replacing a lost or removed tooth. The OmniTaper EV implant is a further development of existing dental implants. It is made of titanium, a metal that is well tolerated by the human body, which has been successfully used in dental implants for more than 40 years. All components used in this study are available on the market, are CE-marked and will be used according to intended use and approved instructions.

The study involves at 11 planned clinic visits including follow-up visits 6 months and annually until 5 years after installation of the permanent crown. after over a period of about five and a half years. The treatment method and healing period may vary depending on the individual case and treatment plan and additional visits may therefore need to be scheduled. The visits and procedures are the same as standard of care and no procedures will be done just for purpose of research.

The study aims to recruit about 137 men and women from six clinics across Europe (Germany, UK and Switzerland) and participants can only receive one study implant each. Participation is entirely voluntary and participants can choose to withdraw from the study at any time, without giving a reason. The decision to decline or withdraw participation will not affect participants future treatment or care

Active, Not Recruiting

This study is active but is not currently recruiting participants.

Notify Me

Key information

Age range

18 year–75 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Praxis Prof. Dr. Dhom & Kollegen MVZ GmbH, Ludwigshafen, Germany

Loading trial locations.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Willing and able to sign and date the informed consent form.
  • In need of an implant in position 16 to 26 or 36 to 46 (2nd and 3rd molars are excluded), and each subject can only receive one implant.
  • Deemed by the PI/Subinvestigator as likely to present with an initially stable implant situation.
  • A stable occlusion, i.e. an opposing natural dentition, a crown, an implant-supported fixed or removable prosthesis, a partial removable prosthesis or a full denture.
  • An adjacent tooth (root with natural or artificial crown) or an implant-supported crown mesially and distally. Exemption: If the planned implant is in the first molar position, an edentulous space is accepted distally

Exclusion criteria

  • Not willing to participate in the clinical investigation or not able to understand the content of the clinical investigation.
  • Unlikely to be able to comply with clinical investigation procedures according to PI's/Subinvestigator's judgement.
  • Unable or unwilling to return for follow-up visits for a period of 5 years.
  • Severe non-compliance to CIP as judged by the PI/Subinvestigator and/or Dentsply Sirona.
  • Known allergy or hypersensitivity to titanium and/or stainless steel.
  • Uncontrolled pathological process in the oral cavity, e.g. untreated rampant caries and uncontrolled periodontal disease.
  • Uncontrolled para-functional habits, e.g. bruxism.
  • Current need of any Guided Bone Regeneration (GBR) procedure in the planned implant area (gap filling at immediate placement and soft tissue grafting are allowed).
  • Systemic or local disease or condition that would compromise post-operative healing and/ or osseointegration.
  • Immunosuppression, use of corticosteroids, prior or current use of oral or intravenous bisphosphonate, or any other medication such as anti-resorptive therapy or monoclonal antibodies that could compromise post-operative healing and/or osseointegration.
  • Any other condition that would make the subject unsuitable for participation, including but not limited to:
  • History of radiation therapy in the head and neck region.
  • History of chemotherapy within 5 years prior to surgery.
  • Present alcohol and/or drug abuse.
  • Ongoing psychiatric illness.
  • Current smoking/use of tobacco, including e-cigarettes /Not applicable for UK).
  • Any ongoing disease that would make the subject unsuitable for participation, including but not limited to:
  • Recent myocardial infarction (< 3 months*).
  • Recent cerebrovascular accident (< 3 months*).
  • Recent cardiac-valvular prosthesis placement (< 3 months*).
  • Hemorrhagic diathesis.
  • Severe liver dysfunction.
  • Known or suspected current malignancy.
  • Uncontrolled diabetes mellitus (as reported by the subject).
  • Florid infection.
  • Pregnant or breastfeeding females. (Pregnancy tests will be performed as per local requirements).
  • Previous enrolment in the present clinical investigation.
  • Involvement in the planning and conduct of the clinical investigation (applies to both Dentsply Sirona personnel and the clinical investigation site).
  • Simultaneous participation in another clinical investigation, or participation in a clinical investigation during the last 6 months that may interfere with the present clinical investigation.

'* < 3 months is a strict exclusion criterion. After 3 month it is up to the investigator to judge whether the subject is considered suitable for participation or not.

Treatment and study plan

OmniTaper EV implants

Device

Partially edentulous subjects in need of one implant in the maxilla or mandible (2nd and 3rd molars excluded) will receive an OmniTaper EV implant system. The study will be done in accordance with standard dental practice using a one- or two-stage surgical protocol and immediate or delayed placement and/or loading.

Other names: OmniTaper EV implants UDI 0739253224012WR

Primary outcomes

  1. Implant survival rate 1 year after permanent restoration by counting implant in place 1 year after permanent restoration

    Time frame: 1 year after permanent restoration (which is estimated to occur approximately 3 months after implant placement).

    Implant survival rate is a binary variable evaluated clinically, i.e. 'Yes' or 'No' where 'Yes' means that the implant is still in place and 'No' means that the implant is not in place. Any implant that has been removed or lost after implant placement visit will be considered a failure, whatever the reason for removal/loss.

Secondary outcomes

  1. Implant survival rate at 3 and 5 years after permanent restoration by counting implant in place.

    Time frame: 3 and 5 year after permanent restoration (which is estimated to occur approximately 3 months after implant placement).

    Implant survival rate is a binary variable evaluated clinically, i.e. 'Yes' or 'No' where 'Yes' means that the implant is still in place and 'No' means that the implant is not in place. Any implant that has been removed or lost after implant placement visit will be considered a failure, whatever the reason for removal/loss.

  2. Change of implant stability quotient value (ISQ) between implant placement and permanent restoration.

    Time frame: From date of implant placement (which is estimated to occur approximately 1 month after enrollment).

    Implant stability will be evaluated by ISQ value using Resonance Frequency Analysis (RFA). The stability is presented as an ISQ value. The higher the ISQ value the higher the stability. Recorded as a numeric value (1-100).

  3. Final and maximum insertion torque value for each implant at implant placement.

    Time frame: At date of implant placement (which is estimated to occur approximately 1 month after enrollment).

    Final and maximum insertion torque value (ITV), based on ITV curve, measured in Ncm.

  4. Surgeon's assessment of implant stability and confidence at implant placement for each implant.

    Time frame: Immediately after implant placement (which is estimated to occur approximately 1 month after enrollment).

    Numerical scale 1-10, where 1 = totally disagree with the statement, and 10 = totally agree with the statement. Statements to be evaluated by the surgeon: "The implant was guided into the prepared osteotomy", "The implant followed the prepared osteotomy", "The implant has a good primary stability". Each statement will be evaluated separately.

  5. Implant success, i.e., number of implants documented as successful at 1, 3 and 5 years after permanent restoration.

    Time frame: 1, 2, 3 and 5 years after permanent restoration (which is estimated to occur approximately 3 months after implant placement).

    Successful implants counted, i.e. 'Yes' or 'No'. An implant will be considered successful if all of the following criteria are fulfilled:

    Implant in place. Lack of evidence of peri-implant radiolucency in X-ray. Less than 1mm vertical bone loss during first year after loading with permanent restoration and 0,2mm annually thereafter.

    Absence of persistent and/or irreversible signs and symptoms such as pain, infections, neuropathies, paresthesia, or violation of the mandibular canal.

  6. Maintenance of marginal bone levels (MBL).

    Time frame: At permanent restoration (which is estimated to occur approximately 3 months after implant placement) and at 1, 3 and 5 years after PR..

    The MBL change from permanent restoration compared to 1, 3, and 5 years. MBLs will be determined from X-rays, expressed as the distance from the implant reference point to the most coronal bone-to-implant contact on the mesial and distal side of the implant. The average will be calculated and compared for each evaluation period.

  7. PPD (Probing Pocket Depth)

    Time frame: At PR (which is estimated to occur approximately 3 months after implant placement) and at 1, 2, 3, 4 and 5 years after PR.

    PPD will be evaluated at four surfaces around the implant (mesial, distal, buccal and lingual), by using a periodontal probe. The distance from the mucosal margin to the bottom of the probe-able pocket will be measured in millimeter. PPD mean values will be calculated on an implant level for each visit. Changes over time will be analyzed.

  8. Bleeding on Probing (BoP)

    Time frame: At PR (which is estimated to occur approximately 3 months after implant placement) and at 1, 2, 3, 4 and 5 years after PR.

    BoP will be evaluated at four surfaces around the implant (mesial, distal, buccal and lingual), by using a periodontal probe. Bleeding will be recorded as presence or absence of bleeding when probing to the bottom of the pocket. The proportion of surfaces with presence of bleeding will be calculated and presented on an implant level for each visit.

  9. Plaque

    Time frame: 6 months, 1, 2, 3, 4 and 5 years after PR (which is estimated to occur approximately 3 months after implant placement).

    Plaque will be recorded as presence or absence of plaque by visual inspection on four surfaces at each implant site.The proportion of surfaces with presence of plaque will be calculated and presented on an implant level for each visit.

  10. Occurrence of Adverse Events (AEs)

    Time frame: From date of implant placement (which is estimated to occur approximately 1 month after enrollment) up to 5 years after permanent restoration (which is estimated to occur approximately 3 months after implant placement).

    Continuously collected and reported AEs at each investigation visit from implant placement.

  11. Occurrence of Adverse Device Effects (ADEs)

    Time frame: From date of implant placement (which is estimated to occur approximately 1 month after enrollment) up to 5 years after permanent restoration (which is estimated to occur approximately 3 months after implant placement).

    Continuously collected and reported ADEs at each investigation visit from implant placement.

  12. Occurrence of Device Deficiencies (DDs)

    Time frame: From date of implant placement (which is estimated to occur approximately 1 month after enrollment) up to 5 years after permanent restoration (which is estimated to occur approximately 3 months after implant placement).

    Continuously collected and reported DDs at each investigation visit from implant placement.

Sponsors and collaborators

Lead sponsor

Dentsply Sirona Implants and Consumables

Industry

Registry information

Official study title

Clinical Investigation Title: An Open, Prospective, Multicenter Investigation to Evaluate the Clinical Outcome of OmniTaper EV Implants in Extraction Sockets and Healed Ridges - A 5-year Follow-up

Important dates

Study start
2022
Primary completion
2028
Study completion
2029
First posted
May 2, 2022
Registry last updated
Feb 17, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.