Skip to main content
OpenTrials
Completed

NCT Number: NCT01221649

Monitoring of Fluid Status in Heart Failure Patients by Intrathoracic Impedance Measurement in Japan (J-HomeCARE II)

The new BIOTRONIK implantable cardioverter defibrillator (ICD) family Lumax 540 is capable of measuring the intrathoracic impedance on a daily basis and transmission of impedance trend data via the Home Monitoring technology. In future, this will allow for automatic early detection of imminent decompensation at a presymptomatic stage and immediate initialization of clinical meaningful therapeutic interventions preventing heart failure (HF) related hospitalizations. The aim of this investigation is to record long-term impedance trends in heart failure patients with and without heart failure related events (hospitalizations due to acute decompensation) in order to develop algorithms for device-based early detection and warning of HF deterioration accompanied by pulmonary congestion.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 4

Primary location

Kokura Kinen Hospital, Kitakyushu, Fukuoka, Japan

Loading trial locations.

About this study

The new BIOTRONIK ICD family Lumax 540 is capable of measuring the intrathoracic impedance on a daily basis and transmission of impedance trend data via the Home Monitoring technology. In future, this will allow for automatic early detection of imminent decompensation at a presymptomatic stage and immediate initialization of clinical meaningful therapeutic interventions preventing heart failure related hospitalizations. The aim of this investigation is to record long-term impedance trends in heart failure patients with and without HF related events (hospitalizations due to acute decompensation) in order to develop algorithms for device-based early detection and warning of HF deterioration accompanied by pulmonary congestion.

Lumax is the name of a family of implantable ICDs. The primary objective of the therapy is the prevention of sudden cardiac death. The aim is to automatically detect and terminate cardiac arrest caused by ventricular tachyarrhythmia. All major therapeutical approaches from the field of cardiology and electrophysiology are contained within the Lumax family.

Furthermore, the device is capable of treating bradycardia arrhythmias and congestive heart failure. Congestive heart failure is treated with cardiac resynchronization therapy with multisite ventricular pacing known as cardiac resynchronization therapy (CRT).

The integrated Home Monitoring component can provide information about occurring rhythm disturbances and delivered therapies close to real time as well as by intracardiac electrogram (IEGM) Online HD®. Furthermore, statistical data about the patient's condition as well as information about the integrity status of the implant itself are sent.

The implantation of an ICD is a symptomatic therapy with the following objectives:

Termination of spontaneous ventricular fibrillation (VF) through shock delivery Termination of spontaneous ventricular tachycardia (VT) by means of antitachycardia pacing (ATP); in case of ineffective ATP or hemodynamically not tolerated VT with shock delivery Cardiac resynchronization by multisite ventricular pacing (triple-chamber implant) Compensation of bradycardia through ventricular (single-chamber implant) or atrioventricular sequential pacing (dual- and triple-chamber implant)

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patient eligible for 1-, 2- or 3-chamber ICD implantation according to current guidelines or patient already implanted with a Lumax 540 device or successor
  • New York Heart Association (NYHA)-class II to IV
  • Left ventricular ejection fraction (LVEF) lower or equal to 35%
  • Patient accepts Home Monitoring concept and has sufficient Global System for Mobile Communications (GSM) /General Packet Radio Service (GPRS) net coverage
  • Increased risk for HF-related hospitalization according to pre-defined criteria
  • Patient information
  • Informed consent

Exclusion criteria

  • Age < 18 years
  • Contraindication for ICD implantation
  • Post heart transplant (HTX) or actively listed for HTX
  • Cardiac surgery within the previous 3 months or planned at time of inclusion
  • Acute coronary syndrome within the previous 3 months
  • Chronic renal dialysis
  • Pregnant or breast-feeding women
  • Limited contractual capability
  • Participation in another study
  • Anticipated non-compliance with the follow-up scheme
  • Life expectancy not longer than 1.5 years due to a non-cardiac disease

Treatment and study plan

ICD/CRT-D

Device

BIOTRONIK ICD family Lumax 540 and its successors

Primary outcomes

  1. HF Events

    Time frame: 21 months follow-up

    Long-term impedance trends in patients with clinically relevant HF events, to support the development of impedance based detection algorithms. A posterior assessment of sensitivity and false alarm rate of the detection algorithms.

Sponsors and collaborators

Lead sponsor

Biotronik Japan, Inc.

Industry

Registry information

Official study title

Monitoring of Fluid Status in Heart Failure Patients by Intrathoracic Impedance Measurement in Japan

Important dates

Study start
2010
Primary completion
2014
Study completion
2014
First posted
Oct 15, 2010
Registry last updated
Oct 12, 2015

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.