Skip to main content
OpenTrials
Completed

NCT Number: NCT03082456

Molecular Breast Imaging in Screening Breast Cancer

The molecular breast imaging (MBI) is a potential modality to screen breast cancer. In this study, we compare and evaluate the recall rate/diagnostic efficiency of MBI, mammography and breast sonography, and aim to determine best ways of breast cancer screening.

Completed

Looking for future studies?

Notify Me

Key information

Age range

45 year–69 year

Sex eligibility

Female

Study type

Interventional

Phase

Not applicable

Primary location

TzuPei Su

Keelung, 204, Taiwan

About this study

Keywords: molecular breast imaging, MBI, breast cancer, mammography, sonography

  • Background: In breast cancer screening, the sensitivity of mammography is about 71-96 %, but the sensitivity decreases in the three following groups: (1) under 50 years old; (2) dense breast parenchyma; (3) higher risk of breast cancer. The Health and Welfare Ministry data in recent 2 years showed Taiwanese women accepted mammography for screening in the ratio of only about 36%, representing many missed opportunities for early detection. One reason to reject mammography may be the discomfort caused by compression. To solve the above mammography possible weakness, other screening methods came into being, such as molecular breast imaging (MBI) of nuclear medicine. Radiotracer of Tc-99m sestamibi was found for targeting breast tumor 20 years ago, and approved by the FDA in 1997. However, the application is limited due to the suboptimal scanning camera design. Ten years later, the Mayo Clinics developed MBI technology, using small-sized semiconductor detectors. Then it become possible that the nuclear technologist have patient's breast tissue fit the detector in almost the same fashion of mammography without heavy compression.
  • Objective: The aim of this study is to evaluate the recall rate and diagnostic accuracy of MBI, mammography and breast echo, for female population.
  • Study design: Female patients referred to Nuclear Medicine Department for myocardial perfusion scan will be recruited in this study. It is because that MBI and myocardial perfusion scan share the same radiotracer. Then MBI will become additional scanning only. About 1800 female subjects will involve, and further mammography and/or breast sonography will be arranged within 6 months after MBI. Participants will be encouraged to receive mammography every 2 years and telephone survey. We hope that this study will help us to compare and evaluate the recall rate/diagnostic efficiency of MBI, mammography and breast sonography, and to determine best ways of breast cancer screening.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Female patients undergoing myocardial perfusion imaging will be eligible if they sign the informed consent.

Exclusion criteria

  • They are unable to understand and sign the consent form
  • They are physically unable to sit upright and still for 20 minutes.
  • They have undergone breast surgery or breast biopsy within the last 12 months.
  • They have had trauma to the breast tissue or undergone radiation treatment to the breast within the last 12 months.

Treatment and study plan

Molecular breast imaging

Diagnostic Test

Molecular breast imaging will be performed at 5-10 minutes after intravenous injection of 15-20 millicurie (mCi) Tc-99m sestamibi. Both craniocaudal (CC) view and mediolateral oblique (MLO) images of the breast are taken.

Other names: MBI

mammography

Diagnostic Test

During the procedure, the breast is compressed using a dedicated mammography unit. Parallel-plate compression evens out the thickness of breast tissue to increase image quality by reducing the thickness of tissue that x-rays must penetrate, decreasing the amount of scattered radiation, reducing the required radiation dose, and holding the breast still (preventing motion blur). Both craniocaudal (CC) view and mediolateral oblique (MLO) images of the breast are taken.

Other names: Mammogram

Breast ultrasound

Diagnostic Test

Ultrasound investigation of breast is performed by members of breast cancer team. If abnormality is found by the procedure, biopsy will not be performed directly.

Other names: Breast sonography, Breast echo

Primary outcomes

  1. Recall rate

    Time frame: 6 months

    The frequency with which a radiologist or physician interprets findings of an examination as positive

Secondary outcomes

  1. Diagnostic efficacy

    Time frame: 6 months

    The sensitivity, specificity, positive predictive value and negative predictive value of each imaging modality

Sponsors and collaborators

Lead sponsor

Chang Gung Memorial Hospital

Other

Registry information

Important dates

Study start
2015
Primary completion
2018
Study completion
2019
First posted
Mar 17, 2017
Registry last updated
May 13, 2020

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.